Laserfiche WebLink
GGS Series 24 Volt Ceiling Mount Selectable Strobe <br /> Model Part Nominal Candela <br /> Number Number Voltage <br /> GCS24CR 904-1213-002 24VDC 15, 30, 75, 95, 115, 150 <br /> GCS24CW 904-1215-002 24VDC 15, 30, 75, 95, 115, 150 <br /> GCS24PCR 904-1214-002 24VDC 15, 30, 75, 95, 115, 150 <br /> GCS24PCW 904-1216-002 24VDC 15, 30, 75, 95, 115, 150 <br /> GCC Series 24 Volt Ceiling Mount Selectable Horn/Strobe <br /> Model Part Nominal Candela Reverberant dBA � In Anechoic Room <br /> Number Number Voltage 10ft.per ANSI/UL 464 dBA � 10ft. <br /> GCC24CR 904-1209-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 <br /> GCC24PCR 904-1210-002 24VDC 15, 30, 75, 95, 115, 150 81-86 gp <br /> GCC24CW 904-1211-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 <br /> GCC24PCW 904-1212-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 <br /> Model Designations: <br /> C=Ceiling Mount <br /> R= Red Faceplate W=White Faceplate <br /> All units are available in plain (no lettering). <br /> Plain units are non-returnable. <br /> GC24 Product Strobe Current Ratings (mA) <br /> Candela 15cd 30cd 75cd 95cd 115cd 150cd <br /> 24VDC (16-33 Volts) 24VDC 72mA 101 mA 167mA 200mA 214mA 286mA <br /> UL Max' 120mA 120mA 200mA 220mA 290mA 321 mA <br /> GCC24 Product Horn Decibel and Current Ratings (mA) <br /> Minimum dBA � 10ft. Minimum dBA � 10ft. Regulated 24VDC <br /> Horn Mode perANSI/UL 464 perANSI/UL 464 Max.Operating <br /> (HIGH) (LOV1n � High Setting (mA) <br /> emp 3 2400Hz 83 75 23 <br /> emp 3 Mechanical 81 73� 22 <br /> Continuous 2400Hz 86 78 23 <br /> Continuous Mechanical 84 76 22 <br /> NOTES: <br /> • Operating temperature:32°to 120°F(0°to 49°C). The GC Series is not listed for outdoor use. <br /> • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is <br /> producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. <br /> • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see <br /> installation manual. <br /> • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see Technical Bulletin Number 014). <br /> ' Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. <br /> These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The <br /> chime tone is always private mode). <br /> � RMS current ratings are per UL average RMS method. UL max current rating is ihe maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For strobes <br /> the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR <br /> ratings,see installation manual, <br />