Laserfiche WebLink
Conventional GC Series Wiring Diagrams <br /> UL Listed <br /> UL Listed Control <br /> Control Pan�� Signal Signal <br /> Signal Signal s+ s+ s. H+ H- s+ s+ s- H+ H- <br /> Panel Su ervised <br /> g+ 5+ g- H+ H- S+ S+ S- H+ H- p <br /> SuperviSed Q B � 0 Signal+ircuit <br /> ENO OF IINE <br /> Signal Circuit HE5�5,oR <br /> ` + - <br /> END OF LINE <br /> ftE51STOR + <br /> _ \ END Of LINE <br /> RESISTOR <br /> NOTES: <br /> • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing <br /> signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize <br /> the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. <br /> • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) <br /> AND/OR AVSM CONTROL MODULE MANUAL(550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM <br /> CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http•//www gentex com OR CALL GENTEX <br /> CORPORATION AT 1-800-436-8391. <br /> Architect � Engineering Specifications <br /> The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by <br /> Underwriters Laboratories Inc. per ANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC.The notification appliance <br /> shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). <br /> The notification appliance (combination audible/visible units and audible units only) shall produce a peak sound output <br /> of 90dBA or greater as measured at 24VDC in an anechoic chamber.The signaling appliance shall also have the <br /> capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power <br /> wires.Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal <br /> having the ability to be synchronized. <br /> The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz <br /> regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24VDC for the 15 <br /> candela strobe circuit. <br /> The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with <br /> a mounting bracket with terminals with barriers for inpuUoutput wiring and be able to mount to a single gang or double <br /> gang box or double workbox with the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with <br /> either direct current or full wave rectified power. <br /> The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and <br /> be capable of mounting to a surface back box. <br /> 24 units per carton <br /> 29 pounds per carton <br /> �mP�«a��No=�=e: 551-0051-06 <br /> G�N T E X These materials have 6een prepared by Gentex Corporation(Gentex")for informa�ional purposes only,are <br /> necessarily summary,and are no�purported to szrve as legal advice and should not be used as such. <br /> C O R P O R AT 1 O N Gentex makes no representations and wa«anties,express or implied,�ha�these materials are comple(e and <br /> accurate,up-to-dat=,or in compliance with all relevant local,s�ate and tederal laws,regulations and mles. <br /> The materials do not address all le9al considerations as there is inevitable uncertainty reqarding <br /> Fire Protection Products Grou •www. entex.com �nt=_rpre�ation o(laws,regulations and iules and the applica�ion of such laws,regula�ions and rules to <br /> p g particular(act pariems.Each person's activities can diflerenlly aflect the obligations tha�exist under <br /> 10985 Chicago Drive • Zeeland, Michigan 49464 �FpOoa�'e'a`"s,fe9°'a"°"s°"�'e5 rne�ero�e,�hesema�e��,�s�no��dbe�seao��Yfo����o�m,��o�a� <br /> purposes and should not be used as a substiWte for seeking pmfessional le9al advice.Gentex will not be <br /> 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax 1e�F°°5�6ie r°�a°Y a�''°°°�'a°°'e'°a�""�era°°e°P°"�ne��}��m������0���3��ed��m�s m,�e��.,i. <br /> Gzntex Corpora[ion reserves the right[o make changes to the pruduc[data sheet a[their dis<retion. <br />