15 SW EVERETT MALL WAY 2017 EDWARD JONES Plans 2022-11-22
>
Address Records
>
SW EVERETT MALL WAY
>
15
>
EDWARD JONES
>
Plans
>
15 SW EVERETT MALL WAY 2017 EDWARD JONES Plans 2022-11-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 2:34:07 PM
Creation date
5/4/2018 8:30:20 AM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
15
Tenant Name
EDWARD JONES
Permit
E1710-223
Year
2017
Notes
ADD AND RELOCATE HORN AND STROBE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Conventional GC Series Wiring Diagrams <br /> UL Listed <br /> UL Listed Control <br /> Control Pan�� Signal Signal <br /> Signal Signal s+ s+ s. H+ H- s+ s+ s- H+ H- <br /> Panel Su ervised <br /> g+ 5+ g- H+ H- S+ S+ S- H+ H- p <br /> SuperviSed Q B � 0 Signal+ircuit <br /> ENO OF IINE <br /> Signal Circuit HE5�5,oR <br /> ` + - <br /> END OF LINE <br /> ftE51STOR + <br /> _ \ END Of LINE <br /> RESISTOR <br /> NOTES: <br /> • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing <br /> signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize <br /> the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. <br /> • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) <br /> AND/OR AVSM CONTROL MODULE MANUAL(550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM <br /> CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http•//www gentex com OR CALL GENTEX <br /> CORPORATION AT 1-800-436-8391. <br /> Architect � Engineering Specifications <br /> The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by <br /> Underwriters Laboratories Inc. per ANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC.The notification appliance <br /> shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). <br /> The notification appliance (combination audible/visible units and audible units only) shall produce a peak sound output <br /> of 90dBA or greater as measured at 24VDC in an anechoic chamber.The signaling appliance shall also have the <br /> capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power <br /> wires.Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal <br /> having the ability to be synchronized. <br /> The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz <br /> regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24VDC for the 15 <br /> candela strobe circuit. <br /> The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with <br /> a mounting bracket with terminals with barriers for inpuUoutput wiring and be able to mount to a single gang or double <br /> gang box or double workbox with the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with <br /> either direct current or full wave rectified power. <br /> The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and <br /> be capable of mounting to a surface back box. <br /> 24 units per carton <br /> 29 pounds per carton <br /> �mP�«a��No=�=e: 551-0051-06 <br /> G�N T E X These materials have 6een prepared by Gentex Corporation(Gentex")for informa�ional purposes only,are <br /> necessarily summary,and are no�purported to szrve as legal advice and should not be used as such. <br /> C O R P O R AT 1 O N Gentex makes no representations and wa«anties,express or implied,�ha�these materials are comple(e and <br /> accurate,up-to-dat=,or in compliance with all relevant local,s�ate and tederal laws,regulations and mles. <br /> The materials do not address all le9al considerations as there is inevitable uncertainty reqarding <br /> Fire Protection Products Grou •www. entex.com �nt=_rpre�ation o(laws,regulations and iules and the applica�ion of such laws,regula�ions and rules to <br /> p g particular(act pariems.Each person's activities can diflerenlly aflect the obligations tha�exist under <br /> 10985 Chicago Drive • Zeeland, Michigan 49464 �FpOoa�'e'a`"s,fe9°'a"°"s°"�'e5 rne�ero�e,�hesema�e��,�s�no��dbe�seao��Yfo����o�m,��o�a� <br /> purposes and should not be used as a substiWte for seeking pmfessional le9al advice.Gentex will not be <br /> 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax 1e�F°°5�6ie r°�a°Y a�''°°°�'a°°'e'°a�""�era°°e°P°"�ne��}��m������0���3��ed��m�s m,�e��.,i. <br /> Gzntex Corpora[ion reserves the right[o make changes to the pruduc[data sheet a[their dis<retion. <br />
The URL can be used to link to this page
Your browser does not support the video tag.