3003 W CASINO RD 2017 BLDG 45-07 Plans 2022-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-07
>
Plans
>
3003 W CASINO RD 2017 BLDG 45-07 Plans 2022-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2022 1:27:47 PM
Creation date
5/4/2018 11:15:33 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-07
Permit
E1708-171
Year
2017
Notes
REPLACE EXISTING FIRE ALARM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
------__ ..__-- ---�-- _ �_... d_ <br /> A��. BasE EQUIPMENT LEGEND BILL OF MATERIAL <br /> FI R E ALAR M G EN ERAL E�ECTR I CA� N OTES PRo�. PROJ. � � <br /> SYMBOL QT( Qn ITEM DESCRIPTION PART NUMBER MANUFACTURER <br /> 1 . THE INSTALLATION OF THE SYSTEM(S) SHALL MEET THE REQUIREMENTS OF THE FACP 0 1 1 FIRE AI.ARM CONTROL PANEL ENCLOSURE CAB-1 SIEMENS <br /> SPECIFICATION, NFPA 70 (NEC), NFPA 72, ALL APPLICABLE LOCAL CODES, AND � 1 2 CONTROL PANEL MAIN BOARD & DISPLAY PMI-3 SIEMENS <br /> - 3003 WEST CASINO ROAD� � V �RE�T WA 9UZO3 THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. p � 3 <br /> POWER SUPPLY/CHARGER MODULE PSC-12 SIEMENS <br /> 2. FASTEN EQUIPMENT TO STRUCTURAL MEMBERS OF BUILDING OR METAL SUPPORTS � � 4 POWER TERMINATION BOARD PTB SIEMENS <br /> ATTACHED TO STRUCTURE, OR TO CONCRETE SURFACES, <br /> 0 1 5 MODULE CARD CAGE CC-2 SIEMENS <br /> 3. ALL PANELS SHALL BE MOUNTED WITH SUFFICIENT CLEARANCE FOR OBSERVATION, 0 1 6 DIGITAL LINE CARD (SLC CIRCUIT) DLC SIEMENS <br /> TESTING AND MAINTENANCE. ALL JUNCTION BOXES 8c COVERS SHALL BE PAINTED p 1 7 ENCLOSURE INNER DOOR BLANK PLATE ID—SP SIEMENS <br /> RED. <br /> �' S 0 1 8 ADDRESSABLE SMOKE DETECTOR HFP-11 SIEMENS:,. , <br /> 4. ALL WIRE SHALL BE SUPPLIED AND INSTALLED IN COMPLIANCE WITH THE ��' �"'� <br /> REQUIREMENTS OF NFPA 70, ARTICLE 760 AND AS NOTED ON THE DRAWINGS. 0 � 1 9 ADDRESSABLE PULL STATION HMS—D SIEMENS�"`���"^�. • , <br /> IFD � 0 2 10 ADDRESSABLE DUAL INPUT MODULE HTR1-D SIEMENS V� � <br /> 5. A CONSISTENT COLOR CODE FOR FIRE ALARM SYSTEM CONDUCTORS SHALL BE vs 0 E 11 SPRINKLER RISER SHUT OF VALVE BY OTHERS BY OTHERS <br /> F I R E D E T E CT i N �SED TNROUGHOUT THE INSTALLATION. � <br /> 0 ALA <br /> & RM <br /> wF 0 E 12 WATER FLOW SWITCH BY OTHERS BY OTHERS <br /> 6. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION SHALL BE Plv 0 E 13 PIV TAMPER SWITCH BY OTHERS BY OTHERS <br /> � I R E ALAR M DETERMINED IN TNE FIELD BUT SHALL GENERALLY CONFORM TO TO THE LAYOUT 0 1 <br /> SYSTEM ,4 CEILING MOUNTED — — <br /> R E P LAC E M � �I T � HORN STROBE <br /> SHOWN, INSTALLER SHALL MAINTAIN A SET OF DRAWINGS WHICH SHOW ALL ZH MC CR SIEMENS <br /> CHANGES IN ROUTING OF CONDUIT AND/OR CABLING. A COMPLETE SET OF THESE <br /> "MARKED UP" DRAWINGS SHALL BE PROVIDED TO SEATRONICS UPON COMPLETION � . � <br /> OF TNE INSTALLATION. <br /> S C 0 P E 0 F WO R I� : 7. ALL NAC DEVICES SHALL BE INSTALLED IN THE SEQUENCE SHOWN ON THE <br /> DRAWINGS. <br /> THE SCOPE OF WORK FOR THE BOEING 45-07 BUILDING IS TO REPLACE THE FAULTY 8. a,�� F►E�� w�R�N� sHA�� BE TESTE� FOR sHORTs, OPENS AND GROUNDS PRIOR <br /> FIRE ALARM SYSTEM WITH A NEW SIEMENS XLS ADDRESSABLE SYSTEM. MIGRATE THE TO CONNECTION TO THE CONTROL PANEL AND BEFORE DETECTORS ARE PLUGGED <br /> EXISTING TYCO SPRINKLER MONITORING SYSTEM OVER TO THE NEW SIEMENS FIRE iNTo THE easEs. <br /> ALARM SYSTEM AND PROVIDE MONITORING OF ALL SIGNALS THROUGH POINT ID 9. sH�E�� �Ra�N WIRE: uN�Ess oTHERw�sE NOTE�, CABLE SHIELD DRAIN WIRE SHALL <br /> COMMUNICATIONS. BE GROUNDED ONLY AT THE THE PANEL/MODULE OF CIRCUIT ORIGIN. AT ALL . <br /> OTHER LOCATIONS DRAIN WIRE SHALL BE SPLICED THROUGH AND INSULATED FROM <br /> CONTACT WITH ANY POTENTIAL GROUND SOURCE. <br /> SYSTEM DRAWING INDEX <br /> INCLUDED <br /> IN SET <br /> DRAWING N0. SHEET N0. DRAWING TITLE SEQ. N0. <br /> X 110989 E502 COVER, EQUIPMENT LEGEND, BOM 1 <br /> X 110989 1 E260 FLOOR 1 PARTIAL FIRE ALARM PLAN 2 <br /> X 110989 E503 CONNECTION DRAWING — FAP ROOM 3 <br /> . <br /> � � <br /> � <br /> � �� r`�� � : <br /> �� <br /> A��i Z 8 2J�% <br /> CIT�'QF'E�F' <br /> �'�rmit��:r`ii�5�T <br /> ������;�� ���� �����:���� <br /> �,v��`--� <br /> Permit#: E17Q8-141 <br /> Site Addres <br /> s: 30Q3 W CASINO RD� -07 <br /> Qwner: BOEING COMPANY <br /> Tenant: BOEIN6 COMPANY <br /> a��.a�te: s/Zs/zov <br /> Prapased Use: MFG <br /> Descriptian: REPLACE EXISTfN�FIRE ALARM&FIELQ <br /> QEVICES <br /> Reviewed 8y: Date: <br /> �Of�Fice Set 1ok�`�`�-�a*: Fire/Planning Set <br /> �..� �����`������� <br /> ��������������t��� <br /> S U B M I TTAL ������;������� ___ � <br /> PO BOX 1138 <br /> 8.� .�7 _� AUBURN, WA 98071 <br /> ���L�'� JOB N0. 253 DWG N0.O60 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE 111019 111019—E501-0 <br /> AccEPTaB���n SEATRON 7.24.17 FIRE DETECTION & ALARM SYSTEM CURRENT REVISION SYMBo� oATE <br /> suBM�rra� sPEciFicarioNNSAAPPR vE� �HE�KEo BILL OF MATERIAL & NOTES 111019-00 — <br /> SHEET <br /> �0���� � NGI R TITLE <br /> APPROVED BY DEPT. DATE ��0 � <br /> — CHECKED � <br /> — APPROVED �U I L D I N� �V�O� JOB N0. COMP N0. <br /> 111019 . <br /> APPROVED DWG N0. � <br /> ELECTRICAL MASTER — EVEREIT, WA 45-07—E501 <br />
The URL can be used to link to this page
Your browser does not support the video tag.