My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2016 BLDG 40-23 Plans 2022-12-06 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
Plans
>
3003 W CASINO RD 2016 BLDG 40-23 Plans 2022-12-06 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 3:45:05 PM
Creation date
5/8/2018 9:47:01 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Permit
B1602-027
Year
2016
Notes
SLAB ON GRADE IN THE HIGH BAY FUNDATION FOR TOOLING AND EQUIPMENT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I�EG E�1 D <br /> BURIED GROUND CONDUCTOR. <br /> 7 p -� �- SOFTDRA 4/0 AWG,D U�NLESPPER <br /> � � NOTED� OTHERWISE <br /> MATCH LINE (DWG 4�-23- 1 E9d) <br /> �- — — — — — — — — 4/0 AWG GROUND TAP FROM <br /> -� X,�— — — _ — � — - - g - � — �°X � —;-dO�S--- � � � r -G� US�G BO��D CONN�ECTIONST <br /> � � V UNLESS NOTED OTHERWISE <br /> � � � � x — x — x — x — x — x — x — x — x — x — x — x — x — x — x — x — x <br /> #4�0 AWG EQUIPMENT GROUND <br /> � —G (� FOR �UT RIE CON ECT OINSED FLOOR <br /> 6 30'-0" x 3/4" ROUND COPPERWELD <br /> 1 GROUND ROD. TOP OF ROD TO BE <br /> v DRIVEN 2'-6" BELOW FIN. GRADE <br /> 0 � 0 GROUND TEST WELL <br /> 7 1 2 2 � 2 5 �, 2 <br /> SG STATIC GROUND POINT <br /> • G G G G G G G G G G G G G G G G G G G G <br /> S 4 I 3 SG <br /> � 3 " 1 . ALL GROUND CABLE SHALL BE #4/0 SOF—f <br /> " " DRAWN BARE STRANDED COPPER <br /> CONDUCTOR FOR THE MAIN GROUND LOOP <br /> 2 2 2 AND EQUIPMENT GROUNDS, UNLESS <br /> � c� � NOTED OTHERWISE. <br /> " " �J " 2. INSTALL GROUND CABLE AT THE BOTTOM <br /> e9i E5 3 OF THE GRADE BEAM OR A <br /> �, 3 3 TYP 3 3 � MINIMUM OF 2'-6" BELOW GRADE. <br /> 3. EXCEPT AT TEST WELLS, UNDERGROUND <br /> CONNECTIONS AT TAPS AND GROUND RODS <br /> SG SG SG SG SHALL USE CADWELD PROCESS. ' <br /> c� � � � � �, 4. GROUND RODS (3/4" x 10'-0" COPPER <br /> CLAD STEEL) SHALL BE INSTALLED A MINI— <br /> 2 2 OUTSIDE GROUND RODS AT E CTHLBUILDING <br /> PERIMETER COLUMN 5'-0" FROM BUILDING <br /> � � � <br /> � �' i PERIMETER MAXIMUM ,SPACING BETWEEN <br /> , RODS TO BE 150 —0 , <br /> 6 5. ALL GROUND CABLE SHALL BE INSTALLED <br /> � �, � <br /> WITH SUFFICIENT SLACK TO AVOID BREAKAGE. <br /> 6. GROUND CONDUCTORS LEAVING GRADE SHALL <br /> BE PROTECTED BY NON—MAGNETIC SLEEVES. <br /> � TUR �I � IXTURE � � <br /> � � 40-023—E583 STATIC GROUND DETAILS <br /> � <br /> � COf� STRUCT10 �1 NOTES <br /> � � �' ^ 1 PROVIDE AND INSTALL 3/4" X 10' GROUND <br /> � � <br /> � 1 � � w ROD. <br /> = 6 I � <br /> r �, � � � PROVIDE AND INSTALL 4/0 BARE COPPER <br /> z � I <br /> GROUND. <br /> r� � o <br /> � � PROVIDE 10' PIG TAIL FOR CONNECTION TO <br /> � � 8 6 8 6 5 6 6 5 � 5 c� <br /> � LRIP MACHINE STEEL STRUCTURE, COORDINATE <br /> � G G G —$-- G G G G G G G G G G G G Q-- G G G G G G G � G G � FINAL LOCATION WITH EI PRIOR TO ROUGH (N. <br /> o � ►1► <br /> I z 4� PROVIDE 10' PIG TAIL FOR CONNECTION TO <br /> w I �' � � � � � � = LRIP MAIN CONTR�L PANEL. COORDINATE <br /> � U <br /> FINAL LOCATION WITH EI PRIOR TO ROUGH IN. <br /> F-- <br /> `��-° 6 � � BOND GROUND WIRE TO EXISTING BUILDING <br /> " 8 8 � � �, �' GROUNDING SYSTEM <br /> � REPAIR ANY REMOVED GROUNDING CUT OR <br /> � � PULLED UP DURING SLAB ENHANCEMENT FOR <br /> c, LRIP MACHINES <br /> � � 7�' PROVIDE AND INSTALL STATIC GROUND TEST <br /> c� �, POINT +48" AFF ON TOOL AND BOND TO <br /> � GROUNDING PIGTAIL. COORDINATE FINAL <br /> 2 LOCATION WITH EI PRIOR TO ROUGH IN. <br /> 2 <br /> � c� 8�' PROVIDE AND INSTALL 4/0 BARE COPPER <br /> � � " GROUND FOR ROBOT BEDS. COORDINATE <br /> FINAL LOCATIONS WITH EI PRIOR TO ROUGH <br /> IN. <br /> � c-> <br /> � ' � ' 9. 4TH POSITION LRIP WORK TO BE COMPLETED <br /> 1 3 5 7 9 11 � ❑ AFTER THE REMOVAL OF THE TURNSTYLE <br /> " 9 2 4 6 8 1 11 ' � � FIXTURE. <br /> 0 � �' <br /> 1E9c � 1E9d � 1E9e __�� <br /> F' � 6 <br /> 1 E9a � 1 E9b -�------ v � � <br /> � I I ����%��----- �.J <br /> 1 E9f � 1 E9g i 1 E9h �� 1 E9i 1 E9j <br /> ------+-------;--------��������----- <br /> � � <br /> 1 E9k I 1 E91 I 1 E9m i 1 E9n I s E• <br /> .. . <br /> � � � ( � 1 E90 c� c� �4`�oF was�Ltl� <br /> � � "� , � �� <br /> 1 E9p -�-- 1 E9q -'--1 E9r--'-- 1 E9s --'--1 E9t H I ��,� �o� � <br /> � - <br /> KEY PLAN BLDG. 40-23 � ' <br /> c� SCALE: NONE N � � � � "°�o �P 2s2�s � �' www.brph.com Copyrighto2015 <br /> ��, pIST ���' \ `� Architects, Engineers, Constructors <br /> I — — — — — — — — � ss NAL � ���O <br /> � G 5 19020 33rd Ave W,Suite 530 Lynnwood Office <br /> Lynnwood,Washington,98036 <br /> I 4 - 3-1 rl Main#425-255-1095 <br /> N 8' 4' 0 4' 8' 16' CASNE ENG1 NEERI NG, I NC. <br /> S CALE: 1 /8��_ � �—O�� ELECTRICAL AND TECHNOLOGY CONSULTANTS <br /> 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 <br /> SC/��E: �/8��-� �—Q�� (425) 522-1000 WWW.CASNE.COM JOB N0. 151-090 <br /> SYM REYISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY H. �I� �2�s.�5 GROUNDING 16123 � 12.16.15 <br /> 0 ISSUE FOR CONSTRUCTION (WING LRIP ONLOAD) 16123 CASNE EEK 12.16.15 THIS DESIGN AND/OR c cK�a <br /> SPECIFICATION IS APPROVED E. KRISPIN 12.16.15 SHEEi' <br /> � aPPRovEo aY DEPT. DATE C. CLUTE 12�6.�5 TITLE FACTORY TRANSFORMATION 40-23 WING LRIP ' <br /> CHECKED 1 E 9� <br /> APPROVED B U I L D I N� 40��� JOB N0. COMP N0. <br /> WO 15/2899-200 <br /> aPPRov � ELECTRICAL MASTER COL G-G.5/7-9 EVERETT, Wq °wc No. 40-23-1 E9i <br />