3003 W CASINO RD 2017 BLDG 40-92 Plans 2022-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-92
>
Plans
>
3003 W CASINO RD 2017 BLDG 40-92 Plans 2022-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2022 3:02:24 PM
Creation date
5/8/2018 9:56:51 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-92
Permit
B1711-020
Year
2017
Notes
INSTALL SUPPORT FOR NEW REFRIGERATION EQUIPMENT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INCLUDED INCLUDED INCLUDED <br /> IN SET IN SET IN SET <br /> DRAWING N0. SHEET N0. DRAWING TITLE REV DATE DRAWING N0. SHEET N0. DRAWING TITLE REV DATE pRAWING N0. SHEET N0. DRAWING TITLE REV DATE <br /> GE�IERAL N1ECF-IA�IICA� E�ECTR CA� <br /> • 40-092—GO GO COVER SHEET B 1 1 .01 .17 O 40-092-1 M60R-13 1 M60R-13 HVAC PIPING PLAN — FIRST FLOOR — REMOVAL B 11 .�1 .17 � 40-092-1 E63R 1 E63R 208Y/120V POWER PLAN — FIRST FLOOR — REMOVAL C 11 .01 .17 SSU E LEGE�I D <br /> � 40-092—G1 G1 COVER SHEET B 11 .01 .17 O 40-092-1 M60R-14 1 M60R-14 HVAC PIPING PLAN — FIRST FLOOR — REMOVAL B 11 .01 .17 • 40-092-1 E65R 1 E65R 208Y/120V POWER PLAN — FIRST FLOOR — REMOVAL F 11 .01 .17 <br /> • 40-092—G2 G2 SYMBOLS AND GENERAL NOTES C 11 .01 .17 . 40-092-1 M60R-15 1 M60R-15 HVAC PIPING PLAN — FIRST FLOOR — REMOVAL B 11 .01 .17 � 40-092-1 E68R 1 E68R 208Y/120V POWER PLAN — FIRST FLOOR — REMOVAL D 11 .01 .17 NOT YET ISSUED <br /> � 40-092-1 M60R-16 1 M60R-16 HVAC PIPING PLAN — FIRST FLOOR — REMOVAL C 11 .01 .17 � 40-092-1 E115R 1 E115R 480Y/277V POWER PIAN — FIRST FLOOR — REMOVAL E 11 .01 .17 <br /> • 40—Q92-1M60R-17 1M60R-17 HVAC PIPING PLAN — FIRST FLOOR — REMOVAL B 11 .01 .17 O PREVIOUSLY ISSUED, <br /> A R� H I T E CT U RA� • 40-092-1 M 115R 1 M 115R PLUMBING PIPING PLAN — FIRST FLOOR — REMOVAL F 11 .01 .17 � 40-092-1 E63 1 E63 208Y/120V POWER PLAN — FIRST F�OOR C 11 .01 .17 NOT IN THIS ISSUE <br /> � 40-092-1 E65 1 E65 208Y/120V POWER PLAN — FIRST FLOOR F 11 .01 .17 • IN THIS ISSUE <br /> • 40-092—RFA168 RFA168 ROOF PLAN A 11 .01 .17 O 40-092—M511 R M511 R DETAILS — REMOVAL B 11 .01 .17 � 40-092-1 E66 1 E66 208Y/120V POWER PLAN — FIRST FLOOR B 11 .01 .17 <br /> . 40-092—A514 A514 MISC. SECTIONS AND DETAILS — 11 .01 .17 � 40-092—M515R M515R HVAC SECTIONS, KITCHEN — REMOVAL B 11 .01 .17 • 4Q-092-1 E68 1 E68 208Y/120V POWER PLAN — FIRST FLOOR D 11 .01 .17 <br /> • 40-092—FS1 .1 R FS1 .1 R CAFETERIA EQUIP. & UTILITIES SCHEDULE — REMOVAL C 11 .01 .17 • 40-092—RFE68 RFE68 208Y/120V POWER PLAN — ROOF A 11 .01 .17 PREL PRELIMINARY ISSUE <br /> • 40-092—FS1 .6R FS1 .6R CAFETERIA EQUIP. & UTILITIES SCHEDULE — REMOVAL C 11 .01 .17 FOR REVIEW OR <br /> • 40-092-1 FS15R 1 FS15R FOOD SERVICE EQUIPMENT PLAN — REMOVAL A 11 .01 .17 INFORMATION ONLY <br /> � 40-092-1 FS18R 1 FS18R FOOD SERVICE EQUIPMENT PLAN — REMOVAL A 11 .01 .17 NOT FOR CONSTRUCTION <br /> � 40-092-1 M60-13 1 M60-13 HVAC PIPING PLAN — FIRST F1.00R B 11 .�1 .17 ORIG ORIGINAL ISSUE <br /> � 40-092-1 M60-16 1 M60-16 HVAC PIPING PLAN — FIRST FLOOR C 11 .Q1 .17 FOR PERMIT, BID, <br /> • 40-092-1 M60-18 1 M60-18 HVAC PIPING PLAN — FIRST FLOOR A 11 .�1 .17 PROCUREMENT OR <br /> • 40-092—RFM68 RFM68 HVAC PIPING PLAN — ROOF A 11 .01 .17 CONSTRUCTION <br /> • 40-092—FS1 .1 FS1 .1 CAFETRIA EQUIP. & UTILITIES SCHEDULE C 11 .01 .17 <br /> • 40-092—FS1 .6 FS1 .6 CAFETRIA EQUIP. & UTILITIES SCHEDULE C 11 .01 .17 A DRAWING REVISION — <br /> 40-092-1 FS13 1 FS13 FOOD SERVICE EQUIPMENT PLAN A 11 .01 .17 SEE SPECIFIC DRAWING <br /> � 40-092-1 FS15 1 FS15 FOOD SERVICE EQUIPMENT PLAN A 11 .01 .17 FOR NATURE OF <br /> ! 40-092-1 FS18 1 FS18 FOQD SERVICE EQUIPMENT PLAN A 11 .01 .17 REVISION <br /> STR U CTU RA� <br /> • 40-092—S502-1 S502-1 SECTIONS AND DETAILS ORG 11 .01 .17 <br /> � �� �� <br /> �� �� �ti� � ���" <br /> �i � O U P <br /> 600 Stewart St., Ste 1400 <br /> Seattle, Washington 98101 <br /> ISSUE F�R PERMIT -re� 206.267.1700 <br /> 11 .01 . 17 FaX 206.267.17�1 <br /> SAZAN #543-1759 <br /> SYM REVISION 8Y APPROVED DATE SYM REVISION BY APPROVED DATE "�� ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> �'� �'�t�'�� THIS DESIGN AND OR CHECKED CUVER SHEET 21241763 g 11 .01 .17 <br /> A 40-87 AND 4Q-88 DATA ROOM COOLING W2048642 SAZAN/AEM PMJ 11.01.17 ��' �r `Y''SrrJ �5=� � <br /> ���' ,, ��0� SPECIFICATION IS APPROVED SNE� <br /> B 40-92 WALK-IN MACHINERY REPLACEMENT & GLYCOL LOOP DEMO 21241763 SAZAN 11.01.17 � �'r �� ';��''���.,���'tl,1'���� APPROVED BY DEPT. DATE ENGINEER T�T�E 40-92 WALK—IN MACHINERY REPLACEMENT & GLYCOL LOOP DEMO <br /> �'� .� �'.�������s �" � CHECKED � � <br /> �� fl41 TLE��'°-t��� APPROVED �U I LD I N G �0-�92 JOB N0. COMP N0. <br /> �S"lONAL T��' <br /> �'�r� <br /> 11/01/2017 APPROVED ARCHITECTURAL MASTER EVERETT, Wq °wc No. 40-092—G1 <br />