MATCHLINE - SEE DWG 45-YD-M110-11
<br /> � _,� -�� - _ -=-Z.,�- ;�_ - - � -- -- -- -- -- - -- - � -- -- ; -- -- - Q �EGEND
<br /> PROFILE 3
<br /> X ¢ 7005 C-3.5 � �
<br /> 7404 C-3.5 � � / ❑ ea I N
<br /> 1 O , � cw WATER
<br /> 7009 C-3.2 � � 3
<br /> (�. 7Q08 C-3.3 � � I ;Q � � Q o I� �
<br /> � � � � QI , (� I I --- A ---- A AIR
<br /> . M 110 16 M5 6 I � � 45-295 2•A s �
<br /> 7011 C-3.9 0 � 26090 C-X.X � � 26091 C-X.X 3"CW � I �
<br /> X 1 TIE-IN POINT TO EXISTING
<br /> 7010 C-3.6 _' __ __ 4�q I 26092 C-X.X 26093 C-X.X "d' I
<br /> ' � CAPS TYP. - A - - A ---- ---- A --- - A � - A ---- A --�W- A -- ---- A ---- --�� - ---- ----
<br /> .
<br /> � x � 110-16 M556 .� �"w $„W A ,--��=�4 q M� q _ _ ___ 4 A
<br /> , ,� BUILDING 45-247 I - A� M� A - A
<br /> SEE PROFILE 5 I �
<br /> X 70�2 c-3.3 � M110-16 M478 � I
<br /> � I I 3 3
<br /> CAPS TYP. 2 7019 C-3.6 I
<br /> � 70�3 C-3.2 � 7 0 1 7 C-3.7 7 0 1 8 C-3.3 M 1 1 0-1 1 M 5 5 8-1 M 1 1 0-1 1 M 5 5 8-1
<br /> I
<br /> � x � � 7015 C-3., -293 -287 I 4 4
<br /> � 7014 C-3.2 3"W -
<br /> x AIR RELEASE & NR � I M 110-11 M55 1 M 110-11 M558-1 �
<br /> 45-247 B
<br /> BLOW-OFF VALVE PIT �°,6 �-3., + � G E N E RA L N OT E S
<br /> I N337,101� E1285250 I
<br /> I 1
<br /> FIRE LANE
<br /> 1 � 4 'rJ-2Z3 FIRE LANE IRE 1 , COMPRESSED AIR RISER. CQNNECT TO EXISTING 2" ANODELESS
<br /> I � RISER REDUCING TO 1" CA UP TQ HOSE STATION COMPRISED OF
<br /> - 110 3/4" VALVE AND 1/2" AND 1 j4" QUICK DISCONNECT HOSE
<br /> �~ -I 1 � 1 COUPLINGS. TERMINATE AT APPRQXIMATELY 3 Ff AFF. SEE
<br /> � I � 45-204-1 A10 FOR LOCATION.
<br /> I R + I � -X X X X X X X X � X X X /\ � � �/ /I�
<br /> I � '
<br /> ' 2"A q __ _ _ �°��2$ � '' /\ � BEUILDING245-�202ERSEETDEfAILP3/45PI202I M 00 FOROX TO
<br /> 9 I � CONTINUATION.
<br /> X � ,� - - ---�, ---_ - �,
<br /> � � I �' a �
<br /> I I � COMPRESSED AIR RISER. CONNECT TO EXISTING 2 ANODELESS
<br /> X � � •N � X � RISER REDUCING TO 1" CA UP TO HOSE STATION COMPRISED OF
<br /> I (
<br /> I 1 I � N 3/4" VALVE AND 1/2" AND 1/4" QUICK DISCONNECT HOSE
<br /> � �i � � I � a ,a COUPLINGS. TERMINATE AT APPROXIMATELY 3 Ff AFF. SEE
<br /> � ^ � x 45 204 1A10 FOR LOCATION.
<br /> X � � i �
<br /> it y - 4. INSTALL 0.008-INCH THICK LINEAR LOW-DENSITY
<br /> I _� M 110-16 M556 l � � � � � POLYETHYLENE FILM AROUND BURIED COPPER WATER LINE AND
<br /> � x 1 � . � � X � � � EXTEND 6-INCHES PAST CONNECTION TO BURIED DUCTILE IRON
<br /> - --- - � �" '8' '� �' � x. � WATER LINE.
<br /> +a rs tic r� ,r�e s�,, �
<br /> �r, 1 � • - r,
<br /> � & 3"WATER • � �
<br /> o � +. � � � 0 5. PROVIDE LINK-SEAL MECHANICAL SLEEVE AT ALL WATER AND
<br /> � 2 01 P OFILE ,¢ � COMPRESSED AIR PIPE PENEfRATIONS OF CONCRETE PANEL
<br /> 1 I 3 56 C-3. � � ON GRADE.
<br /> � w 25002 G-3.1 - - - � ��
<br /> , ,� � a- M110-1 M4�� � REFERENCE DRAWINGS
<br /> � � � 3757 C-3.9 I
<br /> x �.n
<br /> 1 45-231 45-533 • ¢
<br /> o '< � 1 �1.P I � o
<br /> �- �Q � x w CONSTRlJCT101� NOTES
<br /> w 250o c-3.o N M 110-16 M 56 I w
<br /> � CW 2"AIR � 6" N
<br /> I I & 3"NNIATER I x � � � � 1�j' PROVIDE NEW FORWARD HARDSTAND. EXTEND EXISTING DOMESTIC
<br /> WATER AND COMPRESSEQ AIR PIPING AND CONNECT TO NEW
<br /> w � 3735 -3.9 ,a � � w HARDSTANO.
<br /> z 3732 C-3.7 PROFILE 2 I � 6 W Z
<br /> N 3733 C-3.7 l /� "' 3 = 2 PROVIDE NEW REDUCED PRESSURE BACKFLOW PREVENTER AT
<br /> c.=� x W O 4008 -3.2 -16 M4 7 "fi ��06 x � � � FORWARD HARDSTAND.
<br /> a � 4009 -3.3 ---
<br /> I � ¢
<br /> � I 4010 -4.2 � 2 I X �X X X X X �` '�` " 'a � x► � � 3. REFER TO DEfAIL 1 ON DRAWINGS 45-YD-M360 AND
<br /> "7�' 4 ��'j n FWD H S 202 X X X X �
<br /> b< , 4111 -3.9 � ����•2 �"'� "� SE PR FILE I X 45-YD-M361 FOR SIZES OF EXISTING WATER AND AIR PIPING
<br /> f - , 4 I 9� BETWEEN MAIN LINES AND HARDSTANDS. CONFIRM SIZES IN
<br /> � 4021 C-4.9 M 110-16 47 I � FIELD.
<br /> 4022 C-4.8 � �
<br /> _� 40 4 C-4.3 I � _ ° p � 4. INSTALL 0.008-INCH THICK LINEAR LOW-DENSITY POLYETHYLENE
<br /> � FILM AROUND BURIED COPPER WATER LINE AND EXTEND
<br /> 2 C-3.9 q,p - .3 �--11 A-�,wr- --- - - .__ e _ 6 A
<br /> � 4023 C-4.7 � „ - A ' 6-INCHES PAST CONNECTION TO BURIED DUCTILE IRON WATER
<br /> �1 C-4.3 - ?� � I 5 �W � LINE. PROVIDE DIELECTRIC FLANGE AT CONNECTION POINT.
<br /> � � 401 C-4.3 '9 40 7 C-4.0 I
<br /> � »A =Q� 40 6 C-3.8 I 5. PROVIDE LINK-SEAL MECHANICAL SLEEVE AT ALL WATER AND
<br /> �� q �__� ,,._� A `�I _.r_�q��2�A,_ q I ¢
<br /> COMPRESSED AIR PIPE PENEfRATIONS OF CONCREfE PANEL ON
<br /> 2� 40 1 C-4.3 I 1/2"W -�W -_ I � I GRADE.
<br /> I
<br /> � 40 2 C-4.2 � 'N� � � � CONNECT NEW WATER LINE TO EXISTING DOWNSTREAM FRQM
<br /> k 1 3 C-4.3 5 I � � N � EXISTING VALVE.
<br /> � M110-16 M477 I a � a
<br /> ��.
<br /> " R I I
<br /> 15 C-4.5 & 3"WATER �1 10-1 M566 ! 2"CW �
<br /> 202 PROFILE I - A ----- A �W-- A -- _ cw ---
<br /> ' 16 C-4.2 I Q 2"A A A � � � 00 Q1
<br /> 17 C-4.5 SEE PROFILE I � I °
<br /> � � .�. �_
<br /> � I � B a2 � � 03� � . oa r� � � o os
<br /> M 1 1 0-1 6 M 5 5 6 I a O � ° l
<br /> 1 B i 3 c� a� = � �
<br /> � as ep o�� - � os. os
<br /> I � N �„� CONN. BLDG 45-215 � `
<br /> k 1 I
<br /> , I ! i � � SEE DETAIL � .o
<br /> r ( 2 D 2 10 m11 I� 12� 13 14
<br /> I ,a I 2 � � � o
<br /> 1 a M11 -11 M558-2 �� EMERGENCY EYEW M110-16 M360 �� 16� 17 �8 i19
<br /> � � .-� M 110-11 558- ��
<br /> I .
<br /> � � �i o 4 a
<br /> t � + I � M11 -11 M558-2 D �'I 2p � 21 � 22 � 23� 24- 25
<br /> � � I � M110-11 558- ''
<br /> I � �- 1 1/2"A I
<br /> f . I -- --� - ---- --- 2s . - -2� � 2s
<br /> 1 1 2 A � �s c-xx - -
<br /> -- a -- - --- I ___ ?/?"a ° > >/2°cw __ ��_
<br /> A - q � � A ----- A� -- A - - 1 R� � 6 I 9� _ `'+ 30
<br /> � Z CW 1 1/2"W I � 1 1�2•Cyy 2 � �
<br /> 11 a 2 ` `
<br /> 1 J
<br /> � � I �
<br /> I � � � ,
<br /> -- -- -- -- -- -- -- -- -- -- -- -- -- -- � i -- -- � K EY P LAN
<br /> MATCHLINE - SEE DWG 45-YD-M110-21 �
<br /> N G I N E E R S 9�% SU BM ITTAL SCALE: NONE
<br /> PARTAI � P �AI� 40 20 0 20 4o so -
<br /> 1601 Fifth Avenue, Suite 900�Seattle,WA 98101 0
<br /> SCALE: , �� - 40� ►� ph 206.623.0717�fax 206.624.3775 I S S U E D F 0 R P E R M I T .
<br /> �
<br /> coffman.com
<br /> LAST7NG crea�ivity�resups�rela�ionships . . C
<br /> C
<br /> A SUBTITLE CURRENT REVISION SYMBOL DATE «
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE L S ACCEPTABILITY J. O�MALLEY 01.10.10 �
<br /> �� °T AIR AND WATER W4535737 05.09.» �
<br /> � SI,�I � THIS DESIGN AND/OR
<br /> A STALL 110 NEW WATER LINE & VALVES JM 3.1.15 ti, s�, «
<br /> �, � SPECIFICATION IS APPROVED SHEEf
<br /> , o y TITLE 77�X STALL MODIFICATI4NS - PHASE 2 �
<br /> B 777X STALL MODIFICATIONS - PHASE 2 W4535737 CEI MS 05.09.17 �0�,��� � �, APPROVED BY DEPT. DATE M 110 16 �
<br /> CHECKED
<br /> S ITE 45-YD =
<br /> � 36611� APPROVED JOB N0. COMP N0. Q
<br /> C
<br /> � EGiSTEg ��
<br /> s�j�L � APPROVED MECHANICAL MASTER EVERETf, Wq °wc No. 45-YD-M110-15
<br /> 5/9/17 IPAPFR SPAf'.Fl SFF� 45-Yn-���n_nwr,
<br />
|