Laserfiche WebLink
1 <br /> � EI� ERA� � �TES : � <br /> � 1 . GYPSUM BQARD; ALL DIMENSlONS ARE NOMINAL =("0 <br /> PACKED MINERAL WOOL A361 A361 ���� �F STUD, UNLESS NOTED OTHERWiSE. <br /> INSI�LATION 2. ALL FIRE RESISTANT GYPSI�M BOARD (GB} TQ BE <br /> TYPE X cJR TYPE C CORE. <br /> dECK 3. MI(�IMUM ACCEPTABLE METAL STUD AND FURRI�lG <br /> 2 H4UR HORIZQNTAL SHAFT 2 HOUR HaRIZf�NTAL �HAFT �E�� _ _�� _ _ s_ __ __ __ __ _�; � � GHANNEL SIZES AND �AUGE T(� BE AS INDlCATED ON <br /> WALL: 60�CH-34 STUaS, 1 " WALL: 600GH-34 STUDS, 1" � ���r���"�°g' ' THE STRUCTURAL AND/aR ARCHITEGTIJRAL DRAWI�JGS <br /> (2} 5/8" TYPE X LINER PANEL AND (Zj 5/8" !a LINER PANEL AND 2} 5/8" . � SLUITED TRACK FOR FOR THE HEIGHTS INDICATED. <br /> TYPE X GYP B�. AER-�9a38 {2) 5/8 TYPE X ��E X GYP BD, AER-Q9038 � � � INTUMIESCENT STRIP FIRE 1 1/2" DEFLECTION 4. A7 SHOWER, TUB, LaCKER ROOM OR 1NET AREAS, <br /> GYP B� � � GYP BD C � ��� ���� RESIS��fIVE JQINT SF�,LANT ALL GB �CEILINGS OR PARTITIQNS) Ta BE M0ISTURE <br /> z ! RESISTANT T`(PE. AT CERAMIG QR STa�E TILE AREAS, <br /> � �, --- SLQTT D TRACK F(}R PROVIDED CEMENT BOARD IN LIEU OF MR/GWB TO <br /> R � 1 1 " DEFLEC i i0N 1 LA'�ER 5/8" GB <br /> � ' '� EACH SIDE (7F 6" RECEIVE CERAMIC OR ST(7NE TILE. <br /> � MTL STUDS 16" 0� �• WHERE PARTITION TYPE INDICATES STG-RATE� <br /> " CO�STRUCTION, PR(7VIQE AGOU5TICAL SEALANT AT <br /> _r , . , <br /> � � ALL PARTITIONS, PEftIMETERS, RUNNERS, ELECTRICAL <br /> CEILII�G SEE RCP ° °� °�� QU7LEfS, PENETRATIONS, AND OPENINGS. TO MINIMIZE <br /> � a. : SaUND TRANSMIS510N, ELECTRICAL �UTLETS SHALL <br /> �- ry ° .� . � BE SEPARATED BY MINIi�UM C�F QNE STUD. BA�K TQ <br /> '� a � BACK RECEPTACLES ARE NOT A�GEPTABLE. <br /> PARTITION HT OVER 21 ' �� �. PROVIDE FIRE-RATED PARTITIt7NS WHERE INDIGATED. <br /> DT6 7 � 4>' �` fi" 600CH-34 STUDS DE6 8 3 2" fi>' �005-34 STUDS �� 7 1 4,> } 6° DBL 6�OES20 STUDS � . , <br /> �° � ALL PENETRATIONS T� BE FIRE-STOPPE� WITH A <br /> � � , . <br /> x: � �AST IN PLACE lJL-APPROVED METHOD. <br /> . _ �'-- ' Q d . � CflNCRETE WALL. SEE 7. USE 5/8" MOISTURE-RESISTANT GYP�UM B�ARD ON <br /> � � 7 1 4" 6" 500GH-34 STUDS � o STRUCT. PARTITIONS EXPOSED TO RESTRQOMS AND JANITQR <br /> a � 1 " GYP LINER PANEL AND (2j � {2) 5/8" TYPE Xt GYP BD w �6 . � ; ° .: RQOMS. <br /> � , :t �/8 TYPE X GYP BD. SEE � EACH SIDE �F 6 METAL c.� � � � q 8. SEAL GYP5l1M LAYER(S) Ta FLQQR SLAB BEL�W AND <br /> 0 <br /> � PARTITI�N TYPE DS � STUDS C� 16" 0�, � 5 1 4" 4" CH-STUDS � ° �` ° T4 STRUCTURE ABOVE WITH A CC7NTINU4�lJS BEAD <br /> W r UL aES-U415 w L1L DES - U411 ; �4 v . „ <br /> � . <br /> (3/8 MIN.} QF ACOUSTICAL SEALANT. ACOUSTICAL <br /> F :: a 4: . �. <br /> `� �' � 1 GYP LINER PANEL AND 2 . .a SEALANT Ta BE �Y USG, W.H. HENRY, PECQRA OR <br /> N�T REQUIRED FQR RATED �. fVOT REQUIRED FOR RATED ( ) <br /> ASSEMBLY: 5/8" GYP BD � A S S E M B L Y: 5 8" G Y P B D ' S/8" TYPE X GYP BQ. SEE a � ; EQUAL. REFERENCE TO "CAULK" SHALL INDICATE USE <br /> FINISH WHERE LINER AND A�O U S T I C A L I I�S U L A T I U N A C O U S T I C A L I N S U l A T I O N f — <br /> � ,'� FINISH WHERE LINER AND : P TI 10 TYPE DS ° �; , OF ACQUSTICAL SEALANT. , <br /> STl1DS ARE EXPOSE� TO • `"' STIfDS ARE EKPQSED TQ u ° , 9. SEAL AROUND ALL PENETRATIONS. WHERE V41Q5 <br /> INTERIOR OC�UPAN�Y. � I�JTERI(}R OC�UPANCY. ---------��-.._____� ; ACOUSTICAL INSULATION ;� 4 , ` GREATER THAN 1/4" EXIST, �A�K WITH � .5 PCF <br /> AC�}USTICAL SEAIANT, TYP. ACOUSTICAL SEALANT, TYP. FI�ERGLA5S AND SEAL AIRTIGHT. <br /> � Q d� — 1 U.STAGGER ALL JOINTS ON SINGLE LAYER (�R BASE <br /> ` ° LAYER �YPSUM PANELS ON EACH SIDE SO THAT <br /> :� FLOOR FINISH AND BASE, � FLflQR FINISH AND BASE, � , — AL SEAIANT, TYP. : � FLOC}R FINISH A�lfl BA�E, � <br /> JOINTS ARE ON ALTERNATING STtJDS. ON DUUBLE <br /> SEE FINISH SGHEDULE SEE �I�11SH SCHEDULE � � FLOUR FINISH AND BASE, .° SEE FINISH SCHEDULE �qYERS STAGGER �101NTS QF FACE LAYER ONE STUD <br /> �, - ,, .. _ . � �r . .. ,< _ ., . . <br /> SEE FINISH SCHEDULE � � WIDTH FROM BASE LAYER. STAGGER BACK—Tt7-8ACK <br /> �' �.t ` :�, ` , . ' �l ,��i' r�. ,;: •- .� L' ,�. 1'-, • ,t'- _`` .i , ��,i . -/�.- .. ., _;_ .� <br /> .. ,� � ' °�� �� .` ,r'" OUTLEf BOXES ON OPPOSITE SIDES BY TWO STUD <br /> 1NIDTHS. <br /> 11 .WHERE PARTITION IS NOT INSULATED, SEAL ALL 80X � <br /> 2 HQUR RATED - SHAFT WALL AND SHAFT �ALL CEILING 2 HOUR ftATEQ - GYP BD WALL ANQ SHAFT WALL CEILING 2 H�U� RATED - GYP. BOAR� SHAFT WALL TO STRUCTURE CAST IN PLACE OPENINGS AND PENETRATIONS WITH ACC}USTiCAL <br /> DS MG SEALANT. WHERE PARTITION HAS IN�ULATIQN Dt� N�T <br /> T� a" = �' - a" UL: U415 AND AER-(19038 E� �" _ �' - au UL: U411 AND AER-O�Q38 1° e �� _ �n UL: U415, U417 �" _ �' - a" PACK. I�JSIJLATION SH�IJLD BE LQOSE PREFERABLY <br /> , <br /> NOT IN CONTACT WITH BOTH SIOES OF PARTITIQN. <br /> 12.ALL STUDS AT D40R OPENIf�GS SHALL BE DOUBLED <br /> AND CONTINUQUS TO TOP TRACK ABOVE. <br /> 13.REFER T� MATERIAL FINISH SCHEDULE AND <br /> - SPECI�ICATIONS FflR ADDITIQNAL I�lFORMATI�JN <br /> PACKEd MINERAL W(JOL REGARDING FINISH MATERIAL AND SUBSTRATE ON ANY <br /> INSULATIC?N <br /> � PA�TITIQN TYPE. <br /> 14.ALL INTERIUR STUD PARTITIONS SCHEDULED T� <br /> DECK DEc� RECEIVE INSULATION SHALL HAVE SfJUND <br /> - - - - --- - --- - - - - -- -- - - -- - - --- - --- - --- - --- - --- - --- - --- - --- -- -- -- -- -- -- -- --- - - -- - -- <br /> ��.� `3`` - - - - -- -- -- -- -- ATfENUATING �LANKETS, UNLESS �I�TED OTHER4VISE. <br /> ,:, <br /> � ` ;i' _ 15.WHERE GB PARTITION EDGE ALIGNS WITH GMU, <br /> � N ADJUST ALIGNMENT SO THAT GB SURFACE LAMINATES <br /> — AC�USTICAL SEALANT � SLOTTED �' C7VER CMU, EXTEND GB T� NEAREST CORNER. ' <br /> 361 A3�1 80TH SIDES ' � � DEFLECTI�N TRACK ° �r <br /> � �-- DEFLEGTIO� TRACK �- �— 16.A�D 4 HIGH, TOUCH—SA�JDED, A—C, 3/4 PLYWOOD <br /> � <br /> STEEL STUDS C� 16" OC � STEEL STUaS C� 16" OG WAINSC�T (FIRE RETARDANT) O�fER ALL EkPOSED <br /> SLOTTED TRACK FOR - WALLS FACING FACTORY FLOOR. <br /> 1 1 f 2'° DEFLECTI01� � <br /> �TE�A� ��aci�c II`�ITER.IC►R P� TITI LL <br /> SCH� UL <br /> MAXIMUM WALL ��AL STI�Q SIZE STUD SECTIQN MAXIMtJM STUD � <br /> HEIGHT sPAc��� <br /> 1 5 8?' TYPE K GYP BD. � � �3'� TYPE k GYP BD. �1'—p�� 3-5 f 8" — 22 3625125-27 16" t?.C. <br /> � � � ----� � � � GAUGE <br /> � „ _ <br /> 13'—Q�� 3-5 8 20 �625162-33 16" 4.C, <br /> 6"' STUDS, 5/8" G�P BC?ARD GAu�E � <br /> �..►/I� 1 I � l"'1 � E � c 16'-0" 6„ _ 22 GAUGE 600S125-2T 16" O.C. <br /> ACOUSTICAL INSULATION � ���� � t�.J�TI�� � �C�� L�� <br /> C�E�`L.E�TI C.�1�1 TRAC I�C Q E F'LE�TI C:�1\l TRAC.�`.� 2o�—�'s 6'� — 22 GAUGE �oos��2—�� ���� a.G, , <br /> 25'-0,> 8° _ 20 GAUGE �OOS162-33 16" O�C. <br /> ACOUSTICAL SEALANT D�FL.E��I�� Tfl/A►��'\ �PTI�11��,7 � <br /> BQTH SIDES � <br /> 3,> _ � '—o" <br /> A36Q A363 <br /> � FLOt�R FINISH AND BRSE, <br /> � 5EE FINISH S�HEDI�LE <br /> � �� „ _ �,. , .. <br /> 1' 6" U 6" 1' 2' <br /> ,�� ,_ ., t <br /> �'",=, '� lr,�.� � , <br /> �aa�a <br /> SCALE: 1 „ � 1 �_a,� ��cis����� <br /> ARCHITEC7 <br /> r ��7 i�ir=na��� ' <br /> �34:11 P:t 4�-t��-2oZv(-05'!3(�'GP�t7j <br /> GYP. BQARD PARTITION TO STRUCTURE — STC 5� �,� � �„ 6i, �" <br /> D5 „ , �, � <br /> � _ � — o WP 1021 <br /> cR cc �. � �� j` t� <br /> SCALE: ��, _ � �_Q,s ��;� �� '����1 ���'��� ����� �Q� - Q . <br /> � <br /> �.������ V����ir����r� �����' � <br /> � <br /> � <br /> 5YM REVISION BY APPRQVED �ATE �YM REVISION B'! APPROVED UATE RAW� � SUBTI7LE CURRENT REVISIt�N SYMB�L DATE � <br /> �� ��5,�, ACCEPTABILITY ��w „ 2� �� PARTITIt��I TYP�S w� ����s5� � 11/26/14 4 <br /> �'�� uT THIS DESIGN AND OR <br /> f� ISSUE FOR CONSTRUCTION RVK GRK 05/22/14 �� °� � GRK KE� 11 26 14 � ` <br /> SPECIFICATtON IS APPROVED SHEET <br /> i ��ciN�siric$ 1 APPROVED BY DEPT. DATE ��K 1 1 26 14 <br /> 1 pCN 1 �VK GRK 05/34/14 ��4� � TITLE 40-27 BUILDING� :`' <br /> Ha.a13� GHECkED <br /> 2 REVISION RELEASE 2 RVK GRK 06/25/14 " _ �_ ��, D�I���I V l7 �V'��7 � <br /> ��'f� �o APPR�VED JOB NQ. CdMP Nf�. Y <br /> 3 REVISION RELEASE 13 KEB GRK 11/26/14 , 15477651 <br /> ��rF oF AUT'���'��P APPRQVED DWG N0. � <br /> ARCHITEGTURAL MASTER EVERETt, WA 40-027-A361 . <br />