My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
500 SE EVERETT MALL WAY A BASE FILE 2018-05-14
>
Address Records
>
SE EVERETT MALL WAY
>
500
>
BASE FILE
>
500 SE EVERETT MALL WAY A BASE FILE 2018-05-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2018 11:33:05 AM
Creation date
5/14/2018 11:33:02 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
500
Unit
A
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' FIRE AIARM �UMMUNICAT�R <br /> NFPA72 (2013ed) 26.6.3.3.2 COMPLIANCE(COIV'T): <br /> 26.5.3.3.2.4 —Transmission Channeis: <br /> 26.6.3.3.2.4(f) <br /> 26.6.3.3.2.4(�—GSS Satisfaction(Con'tj: The requirements of 26.6.3.3.2.4(f)additionally are i�net via <br /> pre-testing of RAT's are the future protected premises by GSS technicians to deterrr�ine suitable <br /> locations of RAT and its respective antenna.GSS technicians before and after instaliation,as well as <br /> acc�ptance testing shail verify compliance by communicating with central station and obtaining the <br /> praper information.It should be noted that proprietary information is utilized to demonstrate <br /> compliance. Proprietary information is acceptable per manufacturers UL compliance. <br /> 26.6.3.3.2.5—System Categories: <br /> Two-way radio a/arm systems shall be divided into two categories on the basis of the following number <br /> of RASSRs present in the system. (Z)A Tvpe 6 System shall have one RASSR and at least two RARSRs. (2j A <br /> Type 7 system shall have more than one RASSR and at least two RARSRs.(3)In a type 7 system,when <br /> more than one RARASR is out of service and,as a resu/t,anKRATs are no longer being supervised, the <br /> affected supervising station shatl be notified.(4)In a Type 6 system,when any RARSR is out of service,a <br /> troubJe signa!shall be annunciated at the supervising station. <br /> 26.6.3.3.2.5—GSS Satisfaction:Guardian Security network is a Tvpe 7 system.As such,the compliance <br /> of line item(3)notification is automatic,as part of the proprietary software of the manufacturer. <br /> Furthermore,procedures are initiated to troubleshoot and rectify any unexpected outages. <br /> 26.6.3.3.2.6—Laading Capacities: <br /> 26.6.3.3.2.6(a) <br /> Allowable loading capacities shall be in accordance with Tab/e 26.6.3.3.2,6(aJ <br /> 26.6.3.3.2.6(a)—GSS Satisfaction:Compliance shall be checked prior to installation.As with other <br /> reporting formats(IE DACR Hunt Groups),Guardian Security Systems maintains own compliance:At <br /> request of AHJ,Guardian Security Systems can provide documentation of compliance. <br />
The URL can be used to link to this page
Your browser does not support the video tag.