My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 SE EVERETT MALL WAY BRICKS AND MINIFIGS 2018-05-14
>
Address Records
>
SE EVERETT MALL WAY
>
607
>
BRICKS AND MINIFIGS
>
607 SE EVERETT MALL WAY BRICKS AND MINIFIGS 2018-05-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2018 1:33:14 PM
Creation date
5/14/2018 1:33:07 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
607
Tenant Name
BRICKS AND MINIFIGS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
h� <br /> IVew Cor�rv�ent: Egress doors should swing out towards the path of egress. See TBC <br /> 2015 Sec 1010.1.2.1. <br /> 6. Previous Comment: Tenant space 29 has a kitchen in it. Please provide <br /> documentation that the kitchen and equipment was permitted, inspected and approved. <br /> New Comment: Space 29 appears to have a newly instailed kitchen, please provide <br /> documentation. <br /> 8. Previous Comment: The lavatories have been removed from the wall in both toilet <br /> rooms <br /> b. Full grab bars should be shown in each toilet room. IEBC Section 705.2 <br /> c. New or re-installed lavatories should be shown fully accessible for mounting <br /> heights and clearances. IEBC Section 705.2 <br /> New Comment: Full grab bars (including the vertical grab bars) are to be provided. <br /> Please revise drawings to indicate these requirements. Also, it appears that the sink hot <br /> water line and drain is not wrapped. Please clarify and revise drawings. <br /> All codes cited refer to the 2015 International Building Code (IBC), the 2015 International <br /> Existing Building Code (IEBC), the 2015 International Fire Code (IFC), the 2015 International <br /> Mechanical Code (IMC), and the 2015 Washington State Energy Code (WSEC), as amended by <br /> the State of Washington and adopted by the City of Everett. The current IBC referenced <br /> standard for accessible design is the 2009 "Accessible and Usable Buiidings and Facilities" <br /> (ICC/ANSI A117.1). Federal ADA regulations and standards may be more restrictive. These <br /> comments address building issues only. Additional revisions or additions may be required by <br /> other departments (such as Utilities, Traffic, Planning or Fire). All required submittals must be <br /> of sufficient detail and information to ensure that the proposed structure will be constructed in <br /> compliance with all adopted codes. <br /> Sincerely, <br /> Tony Lee <br /> Building OfFicial <br /> -.. <br /> ,�,"�,.�.. _ <br /> ��Zz�`�", .�"". <br /> � <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8813 • P�2'�� �,,, } <br /> �� � <br /> ,�,,,,.. <br />
The URL can be used to link to this page
Your browser does not support the video tag.