Laserfiche WebLink
�� Wiring MS-7AF <br /> a Gam��� Ne� Addressable Pull Station <br /> Document9001-0010 158-3555-000 <br /> �FIRE CONTROL AddreSSabie <br /> INSTRUMENTS From Device <br /> by Honeywell �A+ -}SLC <br /> SLC— <br /> VelocitiT"" Series -- <br /> MS-7AF Addressable Pull Station � � � ° � <br /> Patented,U.S.Patent No.Des.428,351;6,380,846;Other Patents Pending � 1 2 a a Q <br /> Document 9001-0010 156-3555-000 �,,,Q,,,,� � ° • . <br /> Description p p pM��p ° ° <br /> M ��. <br /> The MS-7AF Addressable pull station is a non-coded,dual-action manual pull station with a ���d o��� <br /> ke -lock reset feature.It rovides Gamewell-FCI intelli ent fire alarm control anels FACP '���'� �: <br /> Y P € P ( ) ' ' s�:.�{ .,;; <br /> with one addressable alarni initiating input.The addressable module is housed iuside the '' <br /> pull station.The MS-7AF meets the ADAAG controls and operating mechanisms guidelines <br /> (section 4.1.3[13]), and the ADA requirement far a 5 lb. maximum pull force to activate 0 � � � 0 <br /> the pull station.Operating instructions are molded into the pull station handle along with � <br /> Braille text.Molded Terminal numbers are also present. 8 �`. <br /> - Q a �(��'�� � $ <br /> Ratings O � � <br /> Normal Operating Voltage:24 VDC. �y <br /> Average Operating Current(LED Flash): 300 pA. <br /> Temperature Range:32°F- 120°F(0°C-49°C). . <br /> Relative Humidity Range: 10%-93°�o non-condensing. <br /> CAUTION!Do not detach the door of the pull station during installation.The door of <br /> Installatiun the pull station camiot be reattached to the backplate after the backplate has already been <br /> The MS-7AF Addressable pull station can be surface mounted to an SB-10 or SB-I/O sur- installed onto an electrical box. <br /> face backbox or semi-flush mounted on a standard single-gang,double-gang or 4" (]0.16 <br /> cm) square electricll box.The optional BG-TR trim ring can be used if the MS-7AF is to CAUTION! <br /> be semi-flush mounted. Install the Gamewell-FCI MS-7AF addressable pull station in accordance with these instructions, <br /> applicable NFPA standards,national and local Fire and Electrical codes and the requirements <br /> Operation of the AHJ(Authority Having Jurisdiction).Regular testing of the devices should be conduct- <br /> To activate the dual-action pull station, push in and pull down on the handle. The word ed in accordance widi the appropriate NFPA standards.Failure to follow these directions may <br /> `ACTIVATED'appears after the h�utdle is pulled down.This will remain until the pull sta- result in failure of the device to report an alarm condition.G�unewell-FCI is not responsible for <br /> tion is reset. devices that have been improperly installed,tested or maintained. <br /> The pull station indudes one Single Pole, Single Throw (SPSTj Norm111y Open (N/O) ADA Compliance <br /> switch which closes upon activation of the pull station. ForADA compliance,if the clear fioor space only allows forward approach to an object,the <br /> maximum forward reach height allowed is 48 inches(121.92 cm).If the clear floor space <br /> Resetting the Pull Station allows parallel approach by a person in a wheelchair,the maximum side reach allowed is <br /> 1.Insert the key into the lock and rotate 1/4 turn counterclockwise. 54 inches(137.16 cm). <br /> 2.Open the door until the handle returns to nonnal. <br /> 3.Close and lock the door. <br /> NOTE:Closing the door automatically resets the switch to the`Normal'position.Open- <br />' ing the door will not activate or deactivate the alann switch. (over for Programming i�tformutiorz)r► <br />