) <br /> Instailation Specifications <br /> ASD-PL2F plug-in sensors use a separate base to ASD-PL2F,ASD-PTL2F,ASD-PL2FR: <br /> simplify installation, service, and maintenance. A Dimensions: 2.1"(5.1 cm)height <br /> special tool allows maintenance personnei to plug-in Diameter: 4.1"(10.4 cm)installed in the B501 base <br /> and remove sensors without using a laddec 6.1"(15.5 cm)installed in the B210LP base <br /> Shipping UVeight:5.2 oz. (147 g) <br /> Mount the base on a box which is at least 1.5"(3.8 cm) Operating ASD-PL2F: <br /> deep. Suitable mounting base boxes include: <br /> Temperature: 32° F to 120° F(0°C to 49°C) <br /> ASD-PTL2F: <br /> • 4.0"(10.2 cm)square box. 32°F to 100°F(0°C to 38°C) <br /> • 3.5"(8.9 cm)or 4.0"(10.2 cm)octagonai box. UL�-Listed 0-4000 ft./min. (1,219.2 m/min.), <br /> • Single-gang box(except relay or isolator bases). Velocity Range: suitable for installation in ducts. <br /> • With 6200S or 6200SR base, mounted on a 4.0" Relative <br /> (10.2 cm)octagonai or square box. Humidity: 10-93%(non-condensing) <br /> Thermal Ratings: Fixed-temperature setpoint <br /> • With B224RB or B224BI base, mounted on a 3.5" 135° F(57°C) <br /> (8.9 cm)octagonal box, or a 4.0"(10.2 cm)octagonal or <br /> Spua�e boX. Electrical Specifications <br /> NOTE: Because of the inherent supervision provided Voltage Range: 15-32 volts DC peak <br /> by the SLC, end-of-line resistors are not required. Standby Current: (max.avg.): .0003 A@ 24 VDC <br /> Wiring "T-taps" or branches are permitted for Style 4 (One communication every 5 <br /> seconds with LED blink enabled . <br /> (Class"B")wiring. Maximum Alarm- ) <br /> Sensor Spacing Current: .0065 A@ 24 VDC(LED)lit). <br /> Gamewell-FCI recommends that the spacing sensors B8S@S atlt� �pt10t1S <br /> be used in compliance with NFPA 72. 6501 Plug-in sensor base without flange <br /> Dimensions: 4.1"(10.4cm)diameter <br /> B210LP Flanged mounting base <br /> Dimensions: 6.1"(15.5 cm)diameter <br /> B210LPBP Flanged mounting base bulk pack <br /> Dimensions: 6.1"(15.5 cm)diameter <br /> 6224R6 Plug-in sensor base with auxiliary <br /> Relay Base relay, SPDT, rated 2 amps @ 30 VDC <br /> (resistive). <br /> Screw terminals: <br /> Up to 14 AWG(2.0 mm2) <br /> 2 coil latching relay 1 Form C contact <br /> UUCSA Rating: <br /> 0.9 A@ 125 VAC, inductive <br /> 0.9 A@ 110 VDC, inductive <br /> 3 A@ 30 VDC, resistive <br /> Dimensions: 6.1"(15.5 cm)diameter <br /> Maximum:25 devices between <br /> isolator bases. <br /> 6200S Intelligent sensor sounder base <br /> Dimensions: 6.875"(17.5 cm)diameter <br /> 6200SR Standard sounder base,UL 8649th <br /> Edition compliant, ULC Listed <br /> Dimensions: 6.875"(17.5 cm)diameter <br /> RA100Z Remote LED Annunciator <br /> BCK-200 Black detector covers(box of 10) <br /> DNR Duct smoke housing <br /> --------- ------------ --____----------- <br /> GAMEWELL-FCI <br /> 12 Clintonville Road,Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 <br /> 9020-0617 Rev.J page 2 of 2 www.gamewell-fci.com <br />