My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
811 SE EVERETT MALL WAY TRADER JOES 2018-05-14
>
Address Records
>
SE EVERETT MALL WAY
>
811
>
TRADER JOES
>
811 SE EVERETT MALL WAY TRADER JOES 2018-05-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2018 2:19:22 PM
Creation date
5/14/2018 2:19:17 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
811
Tenant Name
TRADER JOES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> , , <br /> JOB SITE ADDRESS <br /> Trader Joe' s Building *Everett* <br /> 811 SE Everett Mall Way <br /> Everett, WA <br /> APPROVED UL MONITORING COMPANY <br /> Alarm Center, Inc. /FPI <br /> 4300 3rd Ave. SE Lacey, WA 800-429-0991 <br /> UL CERT #902799-02 <br /> CONTRACTUAL RESPONSIBLE PARTIES <br /> Installation; Monitoring; Service; Testing; <br /> Fire Protection, Inc. <br /> AMBIENT TEMPERATURES <br /> No area with alarm service equipment shall <br /> fall below 40 degrees, common areas shall <br /> be at 68 degrees per builder <br /> AN�IENT NOISE RANGE <br /> Al1 areas serviced by the Fire Alarm Control and <br /> notification system will be as listed for <br /> per UBC listings, per builder. <br /> SEQUENCE OF OPERATIONS <br /> Al1 Alarm and Trouble conditions shall enunciate at FACP as well <br /> as remote notify UL listed Central Station. Zones of alarm shall <br /> cause for all notification circuits to activate, send alarm zone <br /> to CS, re-dispatch to Fire and dispatch FPI runner service. <br /> Trouble and supervisory signals shall transmit to CS which will <br /> dispatch FPI runner service to site, (no notification circuits <br /> shall activate. ) On site emergency contact personnel shall be <br /> notified. Wet Waterflow ALARMS shall be retarded by a period of <br /> not more than 45 seconds . Low air shall activate at 251bs, <br /> causing for a supervisory signal. A short on FACP smoke, Waterflow <br /> Switches, (wet and dry) and pull station shall cause alarm. Shorts <br /> on PIV, tamper and Hi-low air zones shall cause a Supervisory <br /> condition. Opens on any zones shall cause for a trouble signal. <br /> Should you have any further questions, please feel free to contact <br /> me directly. <br /> DAVID MOW <br /> V.P. of OPERATIONS / DESIGNER <br /> NICET-III #120904 - CITY OF REDMOND DOR #16-B-141 <br />
The URL can be used to link to this page
Your browser does not support the video tag.