My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1203 SE EVERETT MALL WAY BENT YOGA 2018-05-14
>
Address Records
>
SE EVERETT MALL WAY
>
1203
>
BENT YOGA
>
1203 SE EVERETT MALL WAY BENT YOGA 2018-05-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2018 3:51:45 PM
Creation date
5/14/2018 3:51:37 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1203
Tenant Name
BENT YOGA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�� PUBL/C L�l/O/ZKS <br /> �� <br /> r`�� <br /> December 6, 2017 <br /> Sean Barquist <br /> Corstone Contractors <br /> PO Box 2280 <br /> Snohomish, WA 98290 <br /> sean@coi�stonellc.com <br /> Owner: Everett Mall 11 LLC <br /> Job Address: 1203 SE Everett Mall Way <br /> Plan Check No: B1711-025 <br /> RE: Building Permit Review Letter <br /> Dear Mr. Barquist, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond 1:o the comments below. <br /> General <br /> 1. The following information should be shown/provided on the plans per Section 107.2.1: <br /> a. The drawings should be draw to conventional standards — to include wall <br /> thicknesses and a conventional scale. <br /> b. A diagram should be provided showing where the tenant space is within the <br /> overall building on the site. <br /> c. The plans should state the type of construction, whether the building is <br /> sprinklerd, has a fire alarm and codes in effect. <br /> 2. Elevations and plans should be provided for the accessible toilet rooms and fi�ures that <br /> include the following per Section 1109.2: <br /> a. Mounting heights and lengths of each required grab bar at the toilets and <br /> showers, <br /> b. Toilet seat height, location from wall and clear floor space requirements, <br /> c. Lavatory mounting heights, clearances, clear floor spaces and guarding <br /> requirements, <br /> d. Shower type (roll-in or transfer), seat and clear-floor space requirements. <br /> 3. An exhaust fan should be shown in each toilet room, vented to the outside. IMC Section <br /> 403.3.1.1 <br /> 4. The water fountains (hi-lo are required per Section 1109.5.1) should be detailed on the <br /> plans with mounting heights, elevations and clearances. Section 2902.5.1 <br /> r j,� �; � <br /> ,� <br />
The URL can be used to link to this page
Your browser does not support the video tag.