My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4921 EVERGREEN WAY TROPICAL TAN 2018-05-15
>
Address Records
>
EVERGREEN WAY
>
4921
>
TROPICAL TAN
>
4921 EVERGREEN WAY TROPICAL TAN 2018-05-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2018 8:23:42 AM
Creation date
5/15/2018 8:23:38 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4921
Tenant Name
TROPICAL TAN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 <br /> � . . <br /> . . . • • . <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: Tropical Tan Date 4/3/2017 <br /> A separate MECH-FANSYS form must be completed for every HVAC system that exceeds the 5 hp threshold. For Building Dept.Use <br /> Fan System ID <br /> S stem Su 1 Fa11 Constant Volume(C1�, Uariab/e Air <br /> y pp y CV Vo/ume(VAt�,or HospitaGLab CV <br /> SpeeC� COritY'OI C403.2.>1.9qExceptonr�AVbudgetper <br /> Compliance is based upon either the fan motor nameplate horse power <br /> Com liance O tion Nameplate HP (Option?), the fan brake horsepower(Opfion 2),or C403.7 high efficieny <br /> P P VAV fan brake horsepower(10%/ess than Option 2). The bhp calculation <br /> provides adjustments for special eguipment per Table C403.2.11.9(2). <br /> In Fan Equipment Schedu/e below,provide maximum design supp/y airflow <br /> rate(CFM)of aU supp/y fans serving the conditioned space in Fan <br /> Equipment Schedule below.Fan System CFM Total is the supply airf/ow of <br /> Fan System Supply 2�000 the central air handler at peak design condifions.Additional volumetric air <br /> CFM Total. f/ow provided at zone fan terminals,booster fans,or through induction is <br /> not included in the supp/y CFM totaL However,the fan power of this <br /> equipment is included in the HP and BHP calculations.Fan Sysfem <br /> Supply CFM Total is automatically calculated by the form. <br /> Fan E ui ment 5chedule <br /> Total CFM Total Nameplate Total BHP <br /> Fan ID and Location Fan Type Quantity of Fan Type (Note 1) HP(Note 2) (Note 3) <br /> Unit Supply 1000 2,000 1 1 <br /> Note 1-Total CFM is the maximum CFM of the listed fan(s)when Totai Proposed: 1.0 1.0 <br /> operating at peak design operating conditions. <br /> Note 2-Total namplate hp of the listed fan(s). Total Allowance: 2.2 1.9 <br /> Note 3-Total brake horsepower(bhp)of the listed fan(s)at peak <br /> design operating conditions. Not required <br /> ifNameplate HP compliance option chosen. COIT1pIlanCe Message: COMPLIES <br /> Brake Horsepower Allowance Adjustments <br /> Calculated <br /> Assigned Pressure Adjustment, <br /> CFM thorough this Pressure Drop, <br /> Device Type Description and Location Drop, PD in w.c. A in bhp <br /> deyice(CFMD) (Note 6) PD in w.c. �Note 8) <br /> (Note 7} <br /> Note 4-Bhp atlowance for energy recovery devices and run around coil loops includes both air Total Adjustment(bhp): 0.00 <br /> streams,so the CFMD is the sum of the supply CFM and exhaust CFM if both go through <br /> the device. <br /> Note 5-Energy recovery effectiveness is defined as change in the enthalpy of the outdoor air supply <br /> divided by the enthaply difference between the outdoor air and return air at design conditions. <br /> Note 6-Assigned pressure drop(PD)adjustment per Table C403.2.19.9(2). <br /> Note 7-Pressure drop(PD)adjustment shall be calculated per the applicable method <br /> defined in Table C403.2.11.1(2)based on specific system conditions. <br /> Note 8-A=PD"CFMD/4131 where A is the allowed system brake horse power <br /> adjustment PD is pressure drop allowance,and CFMD is the cfm through the device. <br />
The URL can be used to link to this page
Your browser does not support the video tag.