Laserfiche WebLink
,� -�� Small Sunline (3-6 Ton Page:3 <br /> Package) N543 <br /> Single Package R-410A Air Conditioner <br /> Project Name: CLAREMONT 921 Unit Modei#: ZE060H12A2C1AAA1A1 <br /> Quantity: 1 Tag#:IN STOCK System: ZE060H12A2C1AAA1A1 <br /> Coolin Performance ����:� <br /> �' i a � r - a .>S'� <br /> Total gross capacity 61.1 MBH � � .������, �� ��y, , <br /> Sensible gross capacity 45.4 MBH '�� <br /> Total net capacity 57.8 MBH •b>. � � '� q <br /> Sensible net capacity 42.1 MBH '" <br /> Seasonal Efficiency(at ARI) 14.00 SEER ��' <br /> Efficiency(at ARI) 11.80 EER <br /> Ambient DB temp. 95.0 °F <br /> Entering DB temp. 80.0 °F <br /> Entering WB temp. 67.0 °F <br /> Leaving DB temp. 59.0 °F <br /> Leaving WB temp. 57.3 °F <br /> Power input(w/o blower) 4.28 kW <br /> Sound power 82 dB A �`� <br /> Refrigerant �'��:,� <br /> Refrigerant type R-410A � <br /> Gas Heating Performance <br /> Entering DB temp. 60 °F 5 Ton <br /> Heating output capacity(Max) 100 MBH <br /> Supply air 2000 CFM • York Units are Manufactured at an ISO 9001 Registered Facility and Each <br /> Heating input capacity(Max) 125 MBH Rooftop is Completely Computer-Run Tested Prior to Shipment. <br /> Leaving DB temp. 106.3 °F Unit Features <br /> Air temp.rise 46.3 °oF . Sin le Sta e Gas Aluminum Steel <br /> SSE 80.6 /0 9 9 <br /> Sta es 1 • Single Stage Cooling <br /> Supply Air Blower Performance • Single Stage Cooling <br /> Supply air 2000 CFM ' 125 MBH Input <br /> Ext.static pressure 0.6 IWG • Unit Cabinet Constructed of Powder Painted Steel,Certified At 1000 Hours <br /> Addl.Unit Losses(Options/Accessories) 0.15 IWG Salt Spray Test(ASTM B-117 Standards) <br /> Blower speed 1103 RPM . Either Supply and/or Return can be Fieid Converted from Vertical to <br /> Duct location Bottom Horizontal Configuration without Cutting Panels. <br /> Motor rating 1.00 HP . Full Perimeter Base Raiis with Buiit in Rigging Capabilities <br /> Actual required BHP 1.02 HP <br /> Power input 0.95 kW • Scroll Compressor <br /> Elevation 0 ft. • Dry Bulb Economizer and Hood(No Barometric Relief Damper)with <br /> Drive type DIRECT Economizer Fault Detection&Diagnostic(Meets ASHRAE 90.1-2013,IECC <br /> Speed tap 5 2015,California Title 24,AMCA 511) <br /> Electrical Data • 1 HP Direct Drive Blower <br /> Power supply 230-3-60 • Unit Ships with 1"Throwaway Filters <br /> Unit min circuit ampacity 32 Amps . Solid Core Liquid Line Filter Driers <br /> Unit max over-current rotection 40 Am s . Replacement Filters:2-(15"x 20"x 1"or 2")and 1-(14"x 25"x 1"or 2"). <br /> Dimensions&Wei ht Unit accepts 1"or 2"wide filters. <br /> Hgt 33 in. Len 83 in. Wth 45 in. • Through-the-Curb and Through-The-Base Utility Connections <br /> � Wei ht with facto installed options 4 Ibs. . Short Circuit Current:5kA RMS Symmetrical <br /> Clearances • Single Point Power Connection <br /> Right 24 in. Front 32 in. Back 36 in. • Microchannel All Aluminum Condenser Coii,Copper tube/Aluminum fin <br /> Top 72 in. Bottom 0 in. Left 36 in. Evaporator Coil <br /> Note: Please refer to the tech guide for listed maximum static pressures • Galvanized Steel Drain Pan <br /> • Standard Access Doors <br /> AMERICAN, � � Standard Unit Controller: Simplicity Controi Board <br /> .�nuaun'� cq��,g`-'-M1�{�� <br /> ' °�� � ��Fius , .��� • Safety Monitoring-Monitors the High and Low-Pressure Switches,the <br /> Freezestats,the Gas Valve,if Applicable,and the Temperature Limit Switch <br /> on Gas and Electric Heat Units.The Unit Control Board will Alarm on ignition <br /> m��n�� t^��� �'� � �t'i Failures,Safety Lockouts and Repeated Limit Switch Trips. <br /> 1 fi���-� • An Integrated Low-Ambient Control,Anti-Short Cycle Protection,Lead-Lag, <br /> t i ,� Fan On and Fan off Delays,Low Voltage Protection,On-Board Diagnostic <br /> �,� r�L�l.�'rJpl� .vit"�— and Fault Code Display.Allows all units to operate in the cooling mode down <br /> to 0°F outdoor ambient without additional components or intervention. <br /> BAS Controller <br /> • Simplicity SE Controller including Discharge Air,Return Air,and Outdoor Air <br /> Temperature Sensors <br /> Warranty <br /> • One(1)Year Limited Warranty on the Complete Unit <br /> • Five(5)Year Warranty-Compressors and Electric Heater Elements <br /> • Ten(10)Year Warranty-Aluminized Heat Exchanger <br /> Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 03/30/2017 <br />