Laserfiche WebLink
ENG/NEER/NG <br /> � ��°�� PUBL/C SERV/CES DEPARTMENT <br /> �uiy i4, 2oi� <br /> Kimberly Peaden <br /> Kimberly@aesmech.com <br /> AES Mechanical Services Group, Inc. <br /> 2171ALHwy229S <br /> Tallassee, AL 36078 <br /> RE: Owner: Walgreen's <br /> Job Address: 6807 Evergreen Way <br /> Plan Check Number: M1707-014 <br /> Dear Ms. Peaden, <br /> In response to your application for a construction permit, your plans have been examined and you <br /> are advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. These comments address building issues only. Additional <br /> revisions or additions may be required by other departments (such as Public Works, Planning, or <br /> Fire). All references refer to the 2015 International Building Code (IBC), as amended by the State <br /> of Washington and adopted by the City of Everett. The current IBC referenced standard for <br /> accessible design is the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI A117.1). <br /> Federal ADA regulations and standards may be more restrictive. All required submittals must be of <br /> sufficient detail and information to ensure that the proposed structure will be constructed in <br /> compliance with all adopted codes. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of construction documents <br /> reflecting the corrections requested. All revisions require the person delivering the <br /> drawings to replace the revisions into the two sets here at our offices. For significant <br /> revisions, or if the revisions are coming directly from a document printing facility, <br /> please make arrangements with them to print and deliver two replacement sets. <br /> Structural <br /> 1. Please show the changes in weight between the existing mechanical units versus the new <br /> mechanical units. Per IEBC 2015 Sec 707.2, strengthening of structural elements may be <br /> required per the IBC 2015 code forces if the dead load of the units increase stresses in <br /> existing members by more than 5%. Please have a registered engineer in the state of <br /> Washington provide stamped details and calculations if strengthening is required. <br /> Sincerely, i <br /> �:� .�-� _-�— <br /> �.--�-� �'�— <br /> J4�mes Bronder, PE <br /> Associate Engineer <br /> Plans Examiner <br /> Page 1 of 1 <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax (425) 257-8857 <br />