My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7207 EVERGREEN WAY IGLESIA CRISTIANA PALABRA DE AMOR 2019-01-11
>
Address Records
>
EVERGREEN WAY
>
7207
>
IGLESIA CRISTIANA PALABRA DE AMOR
>
7207 EVERGREEN WAY IGLESIA CRISTIANA PALABRA DE AMOR 2019-01-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2019 11:50:53 AM
Creation date
5/15/2018 9:01:31 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7207
Tenant Name
IGLESIA CRISTIANA PALABRA DE AMOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<TLee @everettwa.�ov> <br /> Subject: Electrical deficiencies @ 7207 Evergreen Way(permit# E1607-037) <br /> Mr. Quintana, <br /> Thank you for your ongoing efforts to identify and correct the electrical concerns and deficiencies within the building <br /> located at 7207 Evergreen Way. (North building) <br /> Here is a summary of our continuing concerns and the required corrections relating to this matter. <br /> Inspection has identified numerous electrical deficiencies and code violations within this building, including but not <br /> limited to: <br /> Open electrical connections, incorrectly sized breakers and wiring, non-compliant electrical installations concealed <br /> behind ceilings. Unsafe wiring installed without required permits and approvals. <br /> A thorough investigation is necessary to identify and correct all electrical deficiencies throughout this building.This <br /> investigation and the associated corrections shall be conducted by the approved contractor of record. <br /> All necessary repairs and corrected work must be inspected and approved by the city's electrical inspector. <br /> This work and the associated investigation shall include, but is not limited to: <br /> 1.To properly assess, identify, and understand the electrical system, a "one line" drawing of the system for this building <br /> must be provided.This drawing must be prepared by a knowledgeable and qualified individual. <br /> 2. Properly and correctly separate all electrical circuits by occupancy throughout this building. <br /> 3. "Safe off" or remove all open electrical conductors and connections within the building. <br /> 4. Correctly size all electrical breakers and wiring throughout the structure. <br /> 5.Any additional electrical defects or code violations that are discovered through investigation or inspection must be <br /> corrected and approved. <br /> Thank you again for your efforts to address and correct the electrical concerns in this matter. <br /> Regards <br /> Ted de Budden <br /> Chief Inspecto'r <br /> Everett Building Department <br /> 425.257 7271 <br /> . <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.