Laserfiche WebLink
, t <br /> � • • : • • ` • • : � <br /> 2015 Washington State Energy Code Compliance Forms for Commerciai Buiidings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Planet Fitness-Everett Date 6/22/2017 <br /> Ca1CillStlOri (� O Addition- � Addition For Building Department Use <br /> L�Tea Nor�e stand alone +e�tisting <br /> �Spaces where<50%of 4 Spaces where z 50%of � <br /> luminaires are replaced luminaires are replaced <br /> LP`� � Standard O Additional Efficiency Package Option O <br /> Calculation 0406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall6e 25%lowerfhan the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximurn Allowed Lighting WattageNOTE � <br /> Location(plan#, Gross Interior Allowed Watts Allowed <br /> Building Area room#,or ALL) Area Description Area in ft2 Watts per ft2 (watts/ftZ x area) <br /> Exercise center ALL Fitness Area 28342 0.67 18990 <br /> Total 28342 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of watts per <br /> Building Area room#) Fixture Description NOTe z,s,a,e Fixtures Fixture Nore s Watts Proposed <br /> Exercise center Exercise Floor Type A LED High Bay 81 110 8 910 <br /> Exercise center Reception Type B Track with(5)LED heads 1 50 50 <br /> Exercise center Tanning Type G LED downlight 49 12 588 <br /> Exercise center Tanning Type H LED downlight 4 12 48 <br /> Exercise center Tanning Type M1 LED wall sconce 3 26 78 <br /> Exercise center Exercise Floor Existing Type L4 pendant 13 13 169 <br /> Exercise center Showers Existing Type L13 2XL fluorescent lay-in 36 62 2232 <br /> Exercise center Exercise Floor Existing Type L14 2x4 fluorescent lay-in 12 64 768 <br /> Exercise center Exercise Floor Existing Type L16 fluorescent downlight 14 17 238 <br /> Exercise center Exercise Floor Existing Type C14 2x4 fluorescent lay-in 12 64 768 <br /> Exercise center Change Room Existing Type L6 sconce 11 60 660 <br /> Compliance by Building Area"o�' <br /> Total Allowed Total Proposed Interior Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Exercise center 18990 14509 COMPLIES <br /> Note 1-List all unique building areas per Tab/e C405.4.2(1)that occur in the Totals 18990 14509 <br /> project scope.Select building area category from drop down menu. <br /> Note 2-Proposed fixtures must be listed in the building area in which they occur.List all proposed lighting fixtures including exempt <br /> lighting eguipment and existing-to-remain fixtures. <br /> Note 3-Forproposed Fixture Description,indicate fixture type,/amp type(e.g. T-8),number of/amps in the fixture,and ba//ast type(if inc/uded). <br /> For track lighting,list the/ength of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 4-For lighting equipment eligib/e for exemption per C405.4.1,note exception numBer and/eave Watts/Fixture blank. <br /> Note 5-Existing-to-remain fixtures shall he included in the Proposed Lighting Wattage taBle in the same manner as new fixtures.Identify as <br /> existing in fixture description. <br /> Note 6-Forproposed Watts/Fixture enter the/uminaire wattage for insta//ed/amp and ba//ast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the/amp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the/arger of the attached/uminaire wattage or <br /> 50 wattsAineal foot,or enter the wattage limit oi permanent current limiting device. <br /> „_�_� „_----��.,-u---�-----��..:,�:__^---...---�_��_._...-•----���_ ��,_.._��.,_u___r__.�_�,,..:,�:__ <br /> - ---...__ __�:__..•-u-_- <br /> � (``, <br /> �� � 1� <br /> �� <br />