My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7621 EVERGREEN WAY PLANET FITNESS 2018-05-15
>
Address Records
>
EVERGREEN WAY
>
7621
>
PLANET FITNESS
>
7621 EVERGREEN WAY PLANET FITNESS 2018-05-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2018 9:31:53 AM
Creation date
5/15/2018 9:31:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7621
Tenant Name
PLANET FITNESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, t <br /> � • • : • • ` • • : � <br /> 2015 Washington State Energy Code Compliance Forms for Commerciai Buiidings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Planet Fitness-Everett Date 6/22/2017 <br /> Ca1CillStlOri (� O Addition- � Addition For Building Department Use <br /> L�Tea Nor�e stand alone +e�tisting <br /> �Spaces where<50%of 4 Spaces where z 50%of � <br /> luminaires are replaced luminaires are replaced <br /> LP`� � Standard O Additional Efficiency Package Option O <br /> Calculation 0406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall6e 25%lowerfhan the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximurn Allowed Lighting WattageNOTE � <br /> Location(plan#, Gross Interior Allowed Watts Allowed <br /> Building Area room#,or ALL) Area Description Area in ft2 Watts per ft2 (watts/ftZ x area) <br /> Exercise center ALL Fitness Area 28342 0.67 18990 <br /> Total 28342 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of watts per <br /> Building Area room#) Fixture Description NOTe z,s,a,e Fixtures Fixture Nore s Watts Proposed <br /> Exercise center Exercise Floor Type A LED High Bay 81 110 8 910 <br /> Exercise center Reception Type B Track with(5)LED heads 1 50 50 <br /> Exercise center Tanning Type G LED downlight 49 12 588 <br /> Exercise center Tanning Type H LED downlight 4 12 48 <br /> Exercise center Tanning Type M1 LED wall sconce 3 26 78 <br /> Exercise center Exercise Floor Existing Type L4 pendant 13 13 169 <br /> Exercise center Showers Existing Type L13 2XL fluorescent lay-in 36 62 2232 <br /> Exercise center Exercise Floor Existing Type L14 2x4 fluorescent lay-in 12 64 768 <br /> Exercise center Exercise Floor Existing Type L16 fluorescent downlight 14 17 238 <br /> Exercise center Exercise Floor Existing Type C14 2x4 fluorescent lay-in 12 64 768 <br /> Exercise center Change Room Existing Type L6 sconce 11 60 660 <br /> Compliance by Building Area"o�' <br /> Total Allowed Total Proposed Interior Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Exercise center 18990 14509 COMPLIES <br /> Note 1-List all unique building areas per Tab/e C405.4.2(1)that occur in the Totals 18990 14509 <br /> project scope.Select building area category from drop down menu. <br /> Note 2-Proposed fixtures must be listed in the building area in which they occur.List all proposed lighting fixtures including exempt <br /> lighting eguipment and existing-to-remain fixtures. <br /> Note 3-Forproposed Fixture Description,indicate fixture type,/amp type(e.g. T-8),number of/amps in the fixture,and ba//ast type(if inc/uded). <br /> For track lighting,list the/ength of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 4-For lighting equipment eligib/e for exemption per C405.4.1,note exception numBer and/eave Watts/Fixture blank. <br /> Note 5-Existing-to-remain fixtures shall he included in the Proposed Lighting Wattage taBle in the same manner as new fixtures.Identify as <br /> existing in fixture description. <br /> Note 6-Forproposed Watts/Fixture enter the/uminaire wattage for insta//ed/amp and ba//ast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the/amp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the/arger of the attached/uminaire wattage or <br /> 50 wattsAineal foot,or enter the wattage limit oi permanent current limiting device. <br /> „_�_� „_----��.,-u---�-----��..:,�:__^---...---�_��_._...-•----���_ ��,_.._��.,_u___r__.�_�,,..:,�:__ <br /> - ---...__ __�:__..•-u-_- <br /> � (``, <br /> �� � 1� <br /> �� <br />
The URL can be used to link to this page
Your browser does not support the video tag.