Laserfiche WebLink
♦4 � � <br /> - M <br /> � � � �:� � � • • � � . <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Planet Fitness-Everett Date 6/22/2017 <br /> The foliowing information is necessary to check a permit appiication for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> MOTORS&TRANSFORMERS <br /> C405.6 Electrical tranformers �nclude electrical transformer schedule on electrical plans; <br /> indicate transformer size,efficiency,or exception taken <br /> Dweliing unit Indicate on electrical plans that each dwelling unit in Group R-2 <br /> C405.7 electrical energy has a separate electrical energy meter <br /> consumption <br /> Electric motor �nclude all motors,including fractional hp motors,in electric <br /> C405.8 efficiency motor schedule on electrical plans;indicate hp,rpm,rated <br /> efficiency,or exception applied <br /> For luminaires in each elevator cab,provide calculated average <br /> efficacy of combined fixtures that indicates efficacy is not less <br /> than 35 lumens per watt; <br /> C405.9.1 Elevator cabs Indicate rated watts per cfm for elevator cab ventilation fans do <br /> not exceed 0.33 watts per cfm; <br /> Indicate automatic controls that de-energize lighting and <br /> ventilation fans when elevator is stopped and unoocupied for a <br /> period of 15 minutes or more <br /> Escalators and �ndicate escalators comply with ASME A17.1/CSA B44; <br /> C405.9.2 moving walks automatic controls are configured to reduce operational speed <br /> to the minimum permitted when not in use <br /> C405.9.3 Regenerative drive �ndicate all one-way down or reversibie escalators are provided <br /> with a variable frequency regenerative drive <br /> Identify all controlled and uncontrolied receptabies on electricai <br /> plans in each space in which they are required;include <br /> Controlied receptacle configuration such as spacing between controlled <br /> C405.10 receptacles and uncontrolled,duplex devices,etc; <br /> Indicate on plans whether the method of automatic controi for <br /> each controlled receptable zone is by occupant sensor or <br /> programmable time-of-day controi <br /> If"no"is selected for any question, provide explanation: <br /> End of Lighting,Motor&Transformer Permit Documents Checklist <br /> __� <br /> t <br /> �� <br /> , � , <br /> �� <br />