Laserfiche WebLink
Global Project Values: <br /> Project Name: Planet Fitness Standby Hours: 24 <br /> �� <br /> Project ID: Alarm Mins:�5 <br /> Prepared By: W estern States Fire Protection Derating Factor: 1.2 <br /> :�: - . Date: 9/20/2017 Voltage Drop Waming <br /> � �. �� Threshold%: 10 <br /> Panel ID: 5808 Model: 5808 Add.Fire Alarm Control Panel Max NAC Current: 3.0 Amps <br /> Location: Electrical Room Volts: 24 VDC Max Panel Current: 6.0 Amps <br /> Ckt.# Circuit Name QtY Current Draw WireAWG Ohms Per Length(ft) Acival Volts @ o/oDrop <br /> Standb Alarm &T e 1000 Ft. One-Wa Ohms EOL <br /> 5808 5808 CTRL Panel 1 0.170 0.365 <br /> SK Photo,Photo-T,PhotoR 1 0.000 0.000 <br /> SK lon 0.000 0.000 <br /> SK Heat,Heat-HT,ROR 0.000 0.000 <br /> SK Beam,Beam-T 0.000 0.000 <br /> SK Duct 0.000 0.000 <br /> SK Acclimate 0.000 0.000 <br /> SK FIRE-CO 0.000 0.000 <br /> SK Control 0.000 0.000 <br /> SK Control-6 0.000 0.000 <br /> SK RelayMon-2 0.000 0.000 <br /> SK Monitor,Minimon 19 0.007 0.007 <br /> SK ' Monitor-2 0.000 0.000 <br /> SK Monitor-10 0.000 0.000 <br /> SK Pull-SA,Pull-DA 0.000 0.000 <br /> SK ' Relay 0.000 0.000 <br /> SK Relay-6 0.000 0.000 <br /> SK Zone 0.000 0.000 <br /> SK Zone-6 0.000 0.000 <br /> SK Isolator Module 0.000 0.000 <br /> B224B1 Isolator Base 0.000 0.000 <br /> B200SR Sounder Base 0.000 0.000 <br /> 820DS Intelligent Sounder Base 0.000 0.000 <br /> B224RB Relay Base 0.000 0.000 <br /> RTS151 Magnetic Remote Test 0.000 0.000 <br /> RTS151KEY Ke Activated Test 0.000 0.000 <br /> RA100Z Remote LED 0.000 0.000 <br /> 5860 LCD Remote Annunc 1 0.020 0.025 <br /> 5824 Serial/Parallel Module 0.000 0.000 <br /> 5496 Power Expander 0.000 0.000 <br /> 5895XL Power Expander 0.000 0.000 <br /> 5865-4 LED Annunciator(4G) 0.000 0.000 <br /> 5865-3 LED Annunciator(3G) 0.000 0.000 <br /> 5880 LED Driver Module 0.000 0.000 <br /> 5883 Relay Module 0.000 0.000 #14 Solid 2.52 365 1.84 18.66 8.55% <br /> NAC#1 Notification Appl Circuit 0.000 0.948 #14 Solid 2.52 0.00 20.40 0.00% <br /> NAC#2 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% <br /> NAC#3 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% <br /> NAC#4 Notification Appl Circuit 0.000 0.000 Total Alarm Current(Amps) <br /> Total Standby Current(Amps) 0.197 1.345 Alarm Time In Minutes/60 (5 Mins) <br /> Standb Time In Hours 24 0.083 Total Alarm AH Re uired <br /> Total StandbyAH Required 4.738 0.112 Command Shortcuts <br /> Totai Combined AH Required 4.85 - -- - - - - <br /> Multiply By The Derating Factor 1.20 Configure Circuits Print Page i <br /> Minimum Battery AmpHours Required 5.82 <br />