Laserfiche WebLink
t 1 T� <br /> . PUBL/� L�Y�R/�C5' <br /> �uiy 3, Zoi� <br /> Ms I/anessa Stephenson <br /> vstephensonC�washingtvnenergy,com <br /> Permit Scope: RE:PLACE GAS WATER HEATER - LONGHORN RESTAURANT <br /> Owner/ Tenant: E��ERGREEN BURG LLC/ LONGHORN RESTAURANT <br /> Job Address: 7�09 EVERGREEN WAY <br /> Permit Number: M:L706-085 <br /> RE: CORRECTIONS Ft�R BUILDING PLAN ARCHITECTURAL REVIEW <br /> The permit application h�s been examined and the drawings are incomplete. Revisions are necessary <br /> before a permit can be i<.�sued. Please review and respond to the comments below. Plan review will <br /> resume when the reques.ted information is submitted and sufficient detail and information is shown to <br /> ensure that the proposed structures will be constructed in compliance with all adopted codes. Additional <br /> revisions may be required for structural comments, or by Public Works, Utilities, Planning, or Fire <br /> departments. <br /> Please provide two replacement sets. If revisions are coming directly from the blue-printer, please make <br /> arrangements with them to print two replacement sets. <br /> General <br /> 1. The permit appliration indicates that new water heater will be installed to replace the existing. <br /> Please identify the size category of the input, per WSEC table C404.2, and the equipment type. <br /> Please use the attached excerpts from the Washington State Energy Code to circle how the new <br /> water heater complies with the performance requirement. <br /> 2. The installation rE�quirements are listed on the second page. Please confirm that the installation <br /> will conform to ef'ficient heater water supply piping, unless the piping is not being altered per <br /> WSEC C404.3. <br /> 3. The water heater should be shown to be installed on an incompressible insulated sur�ace with a <br /> minimum therma� resistance of R-10, per WSEC 404.5. <br /> 4. Please confirm that insulation will be provided on the piping, per WSEC table C403.2.9. <br /> All codes cited refer to the 2015 International Building Code (IBC), the 2015 International Existing <br /> Building Code (IEBC), the 2015 International Property Maintenance Code (IPMC), the 2015 International <br /> Fire Code (IFC), the 201'i International Mechanical Code (IMC), and the 2015 Washington State Energy <br /> Code (WSEC), as amend�d by the State of Washington and adopted by the City of Everett. The current <br /> IBC referenced standard for accessible design is the 2009 "Accessible and Usable Buildings and Facilities" <br /> (ICC/ANSI A117.1). Fed�ral ADA regulations and standards may be more restrictive. Compliance with <br /> these regulations is the responsibility of the tenant and owner of the building. Upon resubmittal of the <br /> drawings, your applicatian will be given priority and plan review will recommence. <br /> CITY OF EVERETT PERMIT SERVICES 3200 CEDAR ST, EVERETT, WA 98209 425-257-8810 <br /> website: www.everettwa.qov/permit ���� general email: everettep�everettwa.qov <br /> �',�i```� <br />