Laserfiche WebLink
ICC A117.1-2009 Chapter 9. Built-in Furnishings and Equipment <br /> �pter � uilt-in Furnishings and Eq i rr,ent <br /> 901 General 903 Benches <br /> 901.1 Scope. Built-in furnishings and equipment 903.1 General. Accessible benches shall comply with <br /> required to be accessible by the scoping provisions Section 903. <br /> adopted by the administrative authority shall compiy g03.2 Clear Floor Space. A clear floor space comply- <br /> with the applicable provisions of Chapter 9. ing with Section 305, positioned for parallel approach to ' <br /> 902 Dining �ur�aces and Work Surfaces <br /> the bench seat, shall be provided. <br /> 903.3 �ize. Benches shall have seats 42 inches (1065 <br /> 902.1 General. Accessible dining surfaces and work mm) minimum in length, and 20 inches (510 mm) mini- <br /> surfaces shall comply with Section 902. mum and 24 inches (610 mm) maximum in depth. <br /> EXCEPYION: Dining surfaces and work surfaces pri- g03.4 Back Support. The bench shall provide for back <br /> marily for children's use shall be permitted to comply support or shall be affixed to a wall. Back support shall <br /> with Section 902.5. be 42 inches (1065 mm) minimum in length and shall <br /> 902.2 Clear Floor Space. A clear floor space comply- extend from a point 2 inches (51 mm) maximum above <br /> ing with Section 305, positioned for a forward approach, the seat surface to a point 18 inches (455 mm) mini- <br /> shall be provided. Knee and toe clearance complying mum above the seat surface. Back support shall be 2'/2 <br /> with Section 306 shall be provided. inches (64 mm) maximum from the rear edge of the <br /> EXCEP710NS: seat measured horizontally. <br /> 1. At drink surfaces 12 inches (305 mm)or less in 903.5 Height. The top of the bench seat shall be 17 <br /> depth, knee and toe space shall not be inches (430 mm) minimum and 19 inches (485 mm) <br /> required to extend beneath the surface beyond maximum above the floor, measured to the top of the <br /> the depth of the drink surface provided. seat. <br /> 2. Dining surfaces that are 15 inches (380 mm) EXCEPTION: Benches primarily for children's use <br /> minimum and 24 inches(610 mm) maximum in shall be permitted to be 11 inches (280 mm) mini- <br /> _ height are permitted to have a clear floor mum and 17 inches (430 mm) maximum above the <br /> space complying with Section 305 positioned floor, measured to the top of the seat. <br /> for a parallel approach. 903.6 Structural Strength.Allowable stresses shall not <br /> be exceeded for materials used where a vertical or hori- <br /> 902.3 Exposed Surfaces. There shall be no sharp or Zontal force of 250 pounds (1112 N) is applied at any <br /> abrasive surfaces under the exposed portions of dining point on the seat, fastener mounting device, or support- <br /> surfaces and work surfaces. ing structure. <br /> 902.4 Height.The tops of dining surfaces and work sur- g03.7 Wet Locations. Where provided in wet locations <br /> faces shall be 28 inches (710 mm) minimum and 34 the surface of the seat shall be slip resistant and shall <br /> inches (865 mm) maximum in height above the floor. not accumulate water. <br /> 902.5 Dining Surfaces and Work Surfaces for Chil- <br /> dren's Use. Accessible dining surfaces and work sur- 904 Sales and Service Counters <br /> faces primarily for children's use shall comply with g04.1 General. Accessible sales and service counters <br /> Section 902.5. and windows shall comply with Section 904 as applica- � <br /> EXCEPTIOIV: Dining surfaces and work surfaces ble. <br /> used primarily by children ages 5 and younger shall EXCEPTION: Drive up only sales or service counters <br /> not be required to comply with Section 902.5 where a and windows are not required to comply with Section <br /> clear floor space complying with Section 305 is pro- g04. <br /> vided and is positioned for a parallel approach. <br /> 902.5.1 Clear Floor Space. A clear floor space com- 904.2 Approach. All portions of counters required to be <br /> plying with Section 305, positioned for forward accessible shall be located adjacent to a walking sur- <br /> approach, shall be provided. Knee and toe clearance <br /> face complying with Section 403. <br /> complying with Section 306 shall be provided. 904.3 Sales and Service Counters. Sales and service <br /> EXCEf'TION: A knee clearance of 24 inches (610 counters shall comply with Section 904.3.1 or 904.3.2. <br /> mm) minimum above the floor shall be permitted. The accessible portion of the countertop shall extend <br /> the same depth as the sales and service countertop. <br /> 902.5.2 lieight.The tops of tables and counters shall 904.3.1 Parallel Approach. A portion of the counter <br /> be 26 inches (660 mm) minimum and 30 inches (760 surface 36 inches (915 mm) minimum in length and <br /> mm) maximum above the floor. 36 inches (915 mm) maximum in height above the <br /> -I ) <br /> � / <br /> si%'� <br />