My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
15 SW EVERETT MALL WAY BASE FILE 2018-05-16
>
Address Records
>
SW EVERETT MALL WAY
>
15
>
BASE FILE
>
15 SW EVERETT MALL WAY BASE FILE 2018-05-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2018 9:56:10 AM
Creation date
5/16/2018 9:56:06 AM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
15
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br /> . <br /> • • • • . � ' - ' • <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised July 2016 <br /> Project Title: Evergreen Summit Retail Center-Suite E and F Date 7/1/2016 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS <br /> Lighting controls, For all lighting fixtures,indicate lighting control method on plans <br /> xes C405.2 A7.0 <br /> general for spaces and lighting zone(s)served,or exception taken <br /> Luminaire level Indicate on plans ali fixtures provided with LLLC in lieu of <br /> C405.2 lighting controls C405.2 lighting controls;provide description of control <br /> (LLLC) capabilities and performance parameters <br /> For permanently installed lighting fixtures in dweliing units, <br /> C405.1 Lighting in dwelling indicate lighting control method on plans for spaces and <br /> units lighting zone(s)served,or demonstrate compliance with high <br /> efficacy exception <br /> C405.2.3 Indicate on plans the method of manual lighting control(whethe <br /> C405.2.1.1 <br /> xes C405.2.2.2 Manual controls combined with occupancy sensor,automatic light reduction, A7.0 <br /> C405.2.4 daylight responsive or specific application controls),location of <br /> C405.2.5 manual control device and area or specifice application it serve <br /> C405.2.2.1 Indicate on plans which method of manual 50%lighting load <br /> Yes C405.2.2.2 Manual interior reduction is provided,or whether lighting load is reduced via A7.0 <br /> C405.2.3 lighting controls occupancy sensors or daylight responsive controls <br /> Indicate on plans the method of automatic shut-off control <br /> during unoccupied periods(occupancy sensor or time switch) A7.0 <br /> Yes C405.2.2 Method of automatic for all lighting zones; <br /> shut-off control Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor or digital timer switch)or which A7.0 <br /> time switch control exception appiies <br /> Indicate on plans the spaces served by occupancy sensors; <br /> — ---- - ----- ---- _.__._._ _._.--. _-- _ ____ _ --__ <br /> xes C405.2.1 Occupancy sensor Indicate whether occupancy sensor controls are configured to <br /> C405.2.1.1 controls be manual-on,automatic 50%-on,or serve a space eligible for A7.0 <br /> automatic 100%-on per exception <br /> Occupancy sensor Indicate aisleways and open areas in warehouse spaces <br /> C405.2.1.2 controls- provided with occupancy sensor controls that reduce lighting <br /> warehouses power by 50% <br /> C405.2.6 Digital timer switch Indicate required digital timer switch control function when <br /> control is used <br /> Yes C405.2.2.1 Automatic time Indicate locations of override switches on plans and the lighting A7.0 <br /> switch controls zone(s)served,include area sq.ft. <br /> Indicate primary and secondary sidelight daylight zone areas on <br /> plans,include sq.ft.; <br /> C405.2.4.2 Daylight zones- �ndicate toplight daylight zone areas on plans,include sq.ft.; A7.0 <br /> Ye8 For small vertical fenestration assemblies(rough opening less <br /> C405.2.4.3 Sidelight and toplight <br /> than 10 percent of primary daylight zone)where daylight <br /> responsive controls are not required,provide fenestration area <br /> to daylight zone calculation(s) <br /> Indicate on plans lighting zone(s)served by daylight responsive <br /> controls; <br /> _ . _ __ _ <br /> Identify sidelight and toplight daylight zones that are not <br /> provided with daylight sensing controls and the exception(s) <br /> C405.2.4 Daylight responsive that apply; <br /> controls Indicate on plans the lighting load reduction method- <br /> continuous dimming,or stepped dimming that provides at least <br /> two even steps between 0%-100%of rated power; <br /> Indicate that daylight sensing controls are configured to <br /> completely shut off all controlled lights in the lighting zone <br /> Additional controls- Identify spaces and lighting fixtures on plans that require <br /> C405.2.5 Specific application specific application lighting controls per this section <br /> lighting controls <br /> Indicate on plans that display and accent lighting,and display <br /> C405.2.5- Display and accent case lighting are controlled independently from both general <br /> Items 1&2 lighting area lighting and other lighting applications within the same <br /> space; <br /> Indicate manual and automatic li htin control method <br /> r1�� <br /> ��y � % <br /> �� s,P��. � <br /> �� : <br /> \ <br />
The URL can be used to link to this page
Your browser does not support the video tag.