Laserfiche WebLink
_ i <br /> `•�• -- `` , <br /> I�J ' '' ; <br /> �p�7FliftATFf1 HFA�ff I <br /> - TENANTIMPROVEMENT - <br /> 15 SW Everett Mall Way, Everett, WA 98204 <br /> Evergreen Summit Retail Center <br /> _ RESPONSIBILTY SCHEDULE PROJECT DATA DRAWING INDEX SpaceG-H i <br /> 15 SW Everett Ma11 Way <br /> �L T°� CONSTRUCTION TYPE EXISTING CANSTRUCTION TYPE: <br /> � TYPEVB SPRINKLERED ARCHITECTURAL -- EVEI�ett, WA 98204 � <br /> DESCRIPTION NOTES/COMMENTS T-100 PLOT PLAN,GENERAL NOTES /j�/_ I <br /> i �� ��k �k OCCUPANCY GROUP PRIMARYOCCUPANCV:P MEDICAL CARE T-101 SITE PLAN �)�L1)/�� ��f y�/���� h��1� <br /> Z i <br /> �� <br /> _ zoNiNc T-102 EXAM ROOM AND RECEPTION TEMPLATES Y• ��� V , �V a�it}► c s <br /> , . T-103 CODE INFO � �If <br /> ; .�ae"`��o. APPLICABLE CADES: 20121NTERNATIONAL BUILDING CO�E ���,�w� ��� � • <br /> „"�,��., 20121NTERNATIONAL MECHANICAL CODES T-104 EGRESS PLAN r,` <br /> , ; �,„,.,:�m�k G-100 ADA NOTES AND DETAILS (v 1725 wenlake avenue n <br /> � --�^w--" 2012 UNIFORM PLUMBING CODES , A-100 FLOOR PLAN&PLUM8ING FIXTURE SCHEDULE suite 210 <br /> H"` """°`°" 2o12NATIONALELECTRICCODE � A-101 PARTITIONSCHEDULE seattle,washington 98109 <br /> i are woFx CHAPER 11 IBC AND OTHER IN7ERNATIONAL A-200 FLOOR REF�ECTED CEILING PLAN � <br /> BUIL�ING GO�E REQUIREMENTS FOR BARRIER- A-201 CEILING DETAILS,DOOR SCHEDULE � 206.838.5485 p <br /> ��� � �w�� FREE DESIGN INCLUDING ICCIAN51 A117.1-2009 A300 MISCELLANEOUS DETAILS `� � /„�//� 206.713.4076 m i <br /> '� uerus � 20'12 WASHINGTON ENERGY CODE A-400 FLOOR FINISH PLAN �����r�� /f iL/ �/ 206.464.0700 1 <br /> � 20�2NATIONALFIRECODEWITH A'401 WALLFINISHPLAN �'� � ksmith�smithco.org I <br /> �-�:�.3"'° A-4012 FINISHSCHEDULE I <br /> ._�^_�^d^ �+ WASHMGTONSTATEAMENDMENTS hY�:OWWW.Sn1i1F1CO.Of9/ <br /> —�_ °��"'° _. ALL LOCAL ORDINANCES HAVING JURISOICTION �� <br /> G� � Consultant <br /> �1 ����, OCCUPANCY B-MEDICALCARE <br /> � �... ,.�. r <br /> ��_�� S� � �� �• ���o - o � � � <br /> ���'"— SCOPE OF WORK <br /> � i <br /> �`_ - - THE WORK INCLUDES TENANT IMPROVEMEMS FOR A MEDICAL CARE FACILITY, � � � / / �g� � ���� I I <br /> WORK INCLUDES NON-STRUCTURAL WALLS AND DOORS,NEW FINISHES,NEW � V• V ! �o ' <br /> - CASEWORK,NEW HC TOILETS. I <br /> � �� '���"�`__:�•.�*.�m-^ NEW MECHANICAL RTU S AND DISTRIBUTION OP NEW DUCTS,NENI CONTROLS. I <br /> NEWRTUSINSAMELOCATIONOFIXISTINGCURBS. VICINITY MAP PROJECT SITE MAP PROJECT DIRECTORY ; <br /> Conwlqnt Regisl2lion Archited Registra6on <br /> NEVJ ELECTRICAL LIGHTINGAND POWER,SWITCHING,NEW ELECTRICAL PANELS. LOCATION <br /> y � �J <br /> NEVJPLUMBINGFIXTURES,TOILETS,SINKS,HOTWATERTANK,NEVJWASTEAND = � '�.� `�fi� ARCHITECT: <br /> WATER PiPING,TAPPING INTO EXISTING WASTE LINE - fi re� <br /> smith co Ilc <br /> .,. ' . � � � °' �--_^ 1725WESTLAKEAVENUEN. <br /> ^s {-t,.: � �� � ;y� SUITE210 <br /> _ _ � _C>°` ts '�R�� _\ �p�.y �:.� SEATTLE,WA 98109 <br /> ...,.� .rp.,., ,x�:.� .:, .._t.�.,�... �,�„-.,::^._ �-; �� .. ,.t �' �.�" ��� �+3 -'� AR206T464.T�KLSMRH9 6294 �,.-, r <br /> � '��. :�-�4yr� � �� T:206383.5485 <br /> . .,,. � .:�,��:�F�3�-.;5 . ' �_.,.s... ��. ,,..d+'n �_._....� a. ' _ .i <br /> � i� � REGISTER-D <br /> �� { . ' y� � I E-Mall:ksmi[h smi[hcoor AR�F CT �I <br /> [f� <br /> ` °� LEGAL DESCRIPTION :�� � `� �� � � - °`""ER � <br /> Y � - I Vitla Inte9rated Heatth �� <br /> ' .t...�.n�..r, � _ ° E.�.�_...: � ,_ , V �F, &�. � 'I unn ioo ke-r: �. suirF <br /> �cu,��s ' _ __ '�fe�-�e �.' �a' t <br /> - R �'�� L' 2014 E Madison St#100 <br /> � - Parce�s ooasozollutaoo �' ` �1 STATE 0= WASHINGTON <br /> — 'rvy«.� i: � r r�.: �y,, .,,� SealUe.WA 98122 <br /> � INTERCITYDN18LK011P00-ALLLOT74&PTNLOTi58EGATNWCORL0T15TH is'. _ . ' 1�1.• .' ,�� ��y', <br /> S58'20 OOE ALG NLY LN 163.62FTTH S TO S LN OF SE7/4 SEC 73-2&4 TH W ALG SD 5 LN TO �+ ��.� ��': � TEL 208.726.9595 <br /> � �� }'�� ������� <br /> SWCORL0T15THNALGWWS�LOT75TOP08 : ��� � <br /> } <br /> — � Parcel# Odf3020L101300 � � � �+�, z� � <br /> � ��nr SEC 24 TWP 28 RGE 04RT4)E1/2 NW1l4 NE7/4 LY N OF BRDWY CUT-OFF LESS W 400 FT � �sr '" '^''�". , .. I � �� -° ' I <br /> p�5� C��+� � I AL50 LESS E 15 FT AS MEAS ALG N LN �I �_Sy,.-��F't.� �=., � .` ��� ,i� <br /> W I _ _. _- __ 4.�vi�.{,'yfi '�tl' I t Yv�� � ��V� �� .�' y � � Iss andRevisions I <br /> - PROJECT f ° <br /> I' `���' � ��^TnA' � �S i' '�' � .,� No.eS Date Issues By Chck �� <br /> � HVAC � /111VI`I S('./�LE: �f.T.S. ; I�'3�„rt���:_i h�,m„ � --�1 ) �' �'� 1 06.29.i6 PERMIT �C'-S � <br /> g c�;,i, - _ � _ +y,'�, t':�� � <br /> � <br /> �� � FORA�DRIONALABBREVIATIONS ARCHITECTURAL'ABBREVIATIONS ARCHITECTURAL SYMBOLS <br /> �u��� ' '—�,� SEE OTHER DESIGN DISCIPLINES <br /> —i _ <br /> � � I^ _"_"_"_—_— _ _— '_'—__ — I <br /> SYMBOLS <br /> �� ACOUS. ACOUSTICAL EIEV. ELEVATION L LONG,LENGTH PR. PAIR NORTH ARROW <br /> '��"^^ � ADJ ADJUSTABLE,AOJACENT ELEC. ELECTRICAL L4M. LAMINATE.LAMINATED PROJ. PROJECT DETAIL DETAIL IDENTIFICATION -PROJECT NORTH ' ITEM S.I.O <br /> �a�.... : A.F.F. AeOVE FINISHED FLOOR(SLAB) ENCL ENCLOSURE LF. LINEAR FOOT.LINEAL FOOT PRV PRESSURE REDUCING VALVE CUT LINE-DEFINES THE ARROW REVISION CLOUD � OR N.I.C. <br /> �'�"' -� • ALUM ALUMINUM E�. E�UAL LIQ. LIQUID P.T. PRESSURETREATED �\==�ETAILEDELEMEM � ��ANDDELTA L--J <br /> , q�,.��FY '� �. -'— qNOD. ANODiZED EXH. EXHAUST L.P. LOWPOINT Q.T. �UARRVTILE 3 2 <br /> APPROX. APPftOXIAMTE EXIST. EXISTING LTV✓�. LIGHTWEIGHT QTR. �UARTER (�Q� �TRUENORTH <br /> 8D. BOAftD EXP. EXPANSION MAS. MASONRV R RADIl15 SFIEET VNiERE INDICATOR �, j ITEM S.O.I.0 <br /> B.F.F. BEIOW FINISHED FLOOR(SLAB) EXT. EXTERIOR MAX. MAXIMUM R.C. REFRIGERATION CONTRACTOR ORAWN DOOR MARK ���'�PA.F.F. NqRK,COMROL ' - OR S.I.C. <br /> Y BL�G. BUILDING F.D. FLOOR ORAIN M.8.5. MErAL BUIIDMG SUPPLIER R.C.P. REFLECTED CEILING PLAN � I I <br /> • BLK. BLOCK FDN. FOUNDATION MECH. MECNANICAL R.D. ROOFDRAIN <br /> WALL SECTION DOOR CODE- � OR DATUM POINT - <br /> BLKG. BLOCKING FF FACTORY FINISH MFG. MANUFACTURING R.L. ROOF LEADER �ETAIL IDENTIFICATION �REFER TO . <br /> •.�� BM. eE4M FHS FLATHEADSCREVJ MFR. MANUFACTURER RECO. RECEIVED ��A SCHEDULE SLOPEDIRECTION NEVJCONSTRUCTION-SHOVvNSOLID <br /> � CUT LINE-DEFINES THE 1 <br /> 80T. BOTTOM Fl. FLOOR M.H. MANHOLE REFRIG. REFRIGERATION (/SLOPE OOWN I�WITH DATUM MARK <br /> BTNM. BETWEEN F.I.O. FURNISHEDANDINSTALLED MW. MINI0.IUM REINF. REINFORCING z DETAILEDELEMEM WINDOW,RELITEOR \�i18'PERFOOT 7 ' <br /> � 4 CB CATCNBASIN BYOWNER M.I.P. METALINSULATTEDPANEL ftEQD. RE�UIRED q],01 LOUVERNUIRK <br /> � C.G. CORNER GUARD FIN. FINISH MISC. MISCELLANEOUS R.O. ROUGH OPENMG ��$f{EET WHERE DRAWN <br /> C.I. CASTIRON F.R.P.P. FIBERREMFORCEDPLASTIC M.O. MASONRVOPENMG SCHED. SCHEOULE �"WINDOW �SPRINKLERMAIN ProjeciName �ICIO If1tQ9fOt2'� h20I',h <br /> C.I.P. CASTINPLACE PANEL(5) M.R. MOISTURERESISTANT � S.C. SOLIDCORE BUILDINGSECTION �y NUMBER-REFER <br /> m' C.L CENTERLINE FRT. FIRERETARDANTTREATED MULI. MULLION SHT. SHEET TOSCHEDULE - <br /> CLR. CLEAR FfG. FOOTING M70. MOUNTED SIM. SIMILAR DETAIL IDENTIFICATION <br /> — CLG. CEILING GA. GAUGE MTG. MOUNTING S.I.O. SUPPLIED AND INSTALLED � E�UIPMENT NU1RK EXISTINC�CONSTRUCTION TO RFMAIN Project Number 02016063.01 <br /> CMU CONCRE?EMASONRVUNIT GALV. GALVANIZEO �L MEfAL 9YOWNER 6 -SHOWDLtI��RIFIWO Descriptlon COVERSHEET <br /> COL. COLUMN G.C. GENERALCONTRACTOR N.I.C. NOTINCONTRACT S.I.V. SUPPLIEDANOINSTHLLEO �.01 EQUIPMENT � — � I <br /> CONC. CONCRETE GWB GYPSUM WALLBOARO.GYPSUM NOM. NOMINAL BY VENDOR SNEET 4NiERE DRANRJ 2d NUMBER-REFER � <br /> CONT. CONTINUOUS BOARD N.T.S. NOTTOSCALE S.O.I.C. SUPPLIEDBYOWNERWSTALLED TOSCHEDULE '! <br /> CONSTR. CONSTRUCTION H.B. NOSE BI88 OA. OVERALL BY CONTRACTOR EXTERiOR ELEVATION �FENCE �'/ Computer File T-100.DWG <br /> CONTR, CONTRACTOR H.C. HANDICAPPED O.C. ON CENTER 5�. SQUARE DETAIL IDENTIFICATION ROOM MARK � � <br /> CT. CERAMICTILE M.M. HOLLOWMEfAL O.D. OVERFLOWDRAIN 5.5. SERVICESMK,SANRARYSEWER - <br /> D8L DOt18LE HORIZ. HORIZONTAL O.H. OVERMEAD SST STAINLESS STEEL � ROOM—ROOM NAME IXISTING CONSTRUCTION TO BE SCdI6 AS NOTED <br /> DIM. DIMENSION H.P. HIGH POtNT OPG OPENING STD. STANDARD A3.02 6NEET WHERE DRAWN �pp BREAKLINE <br /> C_-I—ROOM NUMBER _�/ REMOVED�-SHONM�ASHED <br /> DTL. DETAIL HT. HEIGHT OPP. OPPOSITE STL. STEEL � . <br /> D.F. DRINKING FOUNTAIN HTR. HEATER PTN. PPRTRION STRUCT. STRl1CTURE,STRUCTURAL � TBRIPIB(C � <br /> D.S. �ONMSPOUT HVAC HEATING.VENTILATION.AND PERP. PERPENDICULAR SUSP. SUSPENDED MTERIORELEVATION COLUMNGRIDS WALLTYPEAh4RK �'�, � <br /> DWG. DRAWiNG AIRCONDRIONING PL PLATE.PROPERTV LINE SVS. SVSTEM �� All ideas, designs, anangements, and plans indinted or <br /> EA. EACH IBC INTERNATIONAL BUIIDWG CODE PL45.LAM. PLASTIC LAMINATE T TREAD,TOP �DE7AIL IDENTIFICATION � fepresented by thls drawing are owned hy and Me property of <br /> E.F.S. EXTERIOR FINISH SVSTEM INSUL. INSULATION PLYWD. PLYWOOD T.OJ. TOP OF JOIST .O3 6 WALL TVPE 9mlfh CO3 Ilt and We�e Created, evolved, and developed <br /> - E.LF.S. EXTERIORINSUL4TIONAND INT. INTERIOR PLBG. PLUMBWG T.OM. 70POFMASONRY D � O FE fIREEXTINGUISHER for use on antl in connection with the �ed t None of <br /> ' FINISHSVSTEM JT1.fTS. JOINT,JOINTS PNL PANEL,PANELING T.O.P. TOPOFPAftAPET �tSHEETWHEREDRAWN D �X-^NOTE �ec projec <br /> such Ideas, designs, artangemen[s plans shall 6e used <br /> . -- by or disclosed lo anp person, firtn,oro corporation (or any <br /> purpose whatscever wdhout the wrkten pertnisson of snAh w.Ilc. <br /> T- 100 ��f' � <br /> � <br />