. <br /> ; <br /> PUBL/C `l/O/?J�CS" <br /> ENGINEERING /PUBLIC SERVICES DEPARTMENT <br /> December Z1, 2015 <br /> Yoshua Angersbach <br /> yoshadventure@gmail.com <br /> RE: Owner: Angersbach, Yoshua <br /> Job Address: 2314 Hoyt Ave <br /> Plan Check No: BW1511-006 <br /> Dear Mr. Angersbach, <br /> In response to your application for a construction permit, your plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and respond to the <br /> comments below. These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the 2012 <br /> International Building Code (IBC), the 2012 International Fire Code (IFC), the 2012 International <br /> Mechanical Code (IMC), and the 2012 International Energy Conservation (IECC), as amended by the <br /> State of Washington and adopted by the city of Everett. The current IBC referenced standard for <br /> accessible design is the 2009��Accessible and Usable Buildings and Facilities"(ICC/ANSI A117.1). Federal <br /> ADA, FHA, and HUD regulations and standards, including the Fair Housing Accessibility Guidelines may be <br /> more restrictive. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two complete new sets of construction documents reflecting the <br /> corrections requested. <br /> 1. Records and site inspections indicate the prior existence of an NFPA 13R fire suppression <br /> (sprinkler) system throughout the building. The fire code and International Property <br /> Maintenance Code (IPMC) require this system to be maintained and in an operable condition <br /> (IPMC 704.1.). Any plans to repair or �Iter this buildinc� and maintain a m�ilti-family use must <br /> include the provisions for a fully operable NFPA 13R sprinkler system. 1-he alteration and <br /> repair to the existing system must be accomplished by a licensed sprinkler contractor under a <br /> deferred submittal. The plans should include this requirement. <br /> 2. IBC 107.2.1 states`�Construction documents shall be of sufficient clarity to indicate the <br /> location, nature and extent of the work proposed and show in detail that it will conform to <br /> the provisions of this code and relevant laws, ordinances, rules and regulations, as <br /> determined by the building official." The submitted plans do not accomplish this. The scope, <br /> location and detailing of all construction must be included. The code compliance department <br /> reported the recent installations of several new windows. These need to be included. All <br /> references to code should be made to the IBC for new or altered construction and the IMPC <br /> for repairs to existing elements. All references to the IRC should be removed. <br /> 3. The plans should include the requirement for deferred mechanical, electrical, and plumbing <br /> permits for all repairs, alterations, and confirmation of IPMC compliance. <br /> If you have any questions, please call me at 425-257-7264. <br /> 4 /! ./r � <br /> CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (425) 257-8200 • Fax (425) 257-8856 <br />