Laserfiche WebLink
GENERAL YES NO � <br /> Bathroom doors are easily and quickly openable from the outside when locked � <br /> Carbon Monoxide alarms are installed as required in R315.1 on each level ofthe home. � <br /> Smoke alarms are installed on all levels of the dwelling, in each resident sleeping room,outside each separate <br /> sleeping area in the irremediate vicinity of sieeping rooms(R314}_ �; ❑ <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible wa�ar�,��a�a��be heard in all � � <br /> parts of the dwelli�ng upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requsrements. 0 <br /> R325_4 Operable parts of door handles,pulls,latches,bdcs anei other devices installed in AFH shall be operable aWu�e one hand <br /> and shall not require tight grasping,pinching or twisting of the varrist(levee-type). 0 <br /> Pocket doors shatl have graspable hardware availabte when in the dosed or open position. Q <br /> R37.1B Ramps YES NO <br /> I�sside Ramp N�p � <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizorrtaB(8_3%slope)_(Excepteon R31L8_i PJot allovored in AFH) <br /> R31L8.2 Landing Requirecrnenfs:min_3X3 foot landing at top/boftoaro,e�ahere doors open orrto ramps,and morFeere ramp changes <br /> direc6ouas. - <br /> R3259_i Handrails required on both sides of ramp in accordance with R311.83.1—Ed331.8.33_ <br /> outside Ramp N/A� YES NO <br /> R31L8.1 Ma�dmum Slope one unit verlical in twelve un"rts horizor�al(83%slope).(Excepflion R311.8.i BVot altowed in AFH) <br /> R31L8_2 Landing Requirementr:min.3X3 foot landing at top/bottom,where doors open orto rasnps�and where ramp changes � � <br /> direc6ons_ <br /> R3259.1 Handrails required on botfi sides of ramp in acoordance with R311.83.1—R31�8.3.3. � 0 <br /> Guards below are depicted vertiralfy as an example only.All Ramps must have 6uards Q <br /> Handrail both sides <br /> I occ than 4' 3q.-_38� <br /> Y <br /> Guard <br /> 36'min <br /> � 3'x 3°mim <br /> I 9areding <br /> 3'x 3'min <br /> landing <br /> 3' One unit vertical in twetve units horizorrtal �--- ---� <br /> minimum is an 8396 slope all along surface of the ramp_ ' min mum " <br /> R31L2 Means of Egress YES NO <br /> R31�2 Door must be side-tainged with min.wfidtFe o�32 inches betenreen face of door anai stop.Heig9rt cnot 9�ss tfr�ue 78 inches_ <br /> l�325.4 Operable parts of door handles,pulls,la$ches,lodcs and other deeei�s installed in AFH shall l�e operable�e one hand <br /> and shall not require tight grasping,pinching or twsisting of the wrist(lever-type)_ � <br /> R375.4 Required exit door hardvvare shall unlodc ieuide and outside mechanisms when e�atingthe buildBng allowing re-errtry (] <br /> witl�out use of key,tool or special knowledge. Required e�t door shall have no additional locldng devices_ <br /> R311J Stairways NJA YES NO <br /> R311.7.4.1 Riser Height_Max riser height shall be 7�: inches(8 inches in structures built prior to luly 1,2009) " <br /> R3llJ_4_2 Tread Depth:Min_tread depth shall 6e in 10 inches(9 inches in structures built priorto July 1,2004) Q Q <br /> R325_10_l Handrails for Treads and Risers shall be irtsialled on both sides oftreads and risers numbering fnom one riser to muF�iple � � <br /> risers.Handrails shall be installed in accordance with R31L7.7.1—R311.7.7_4 <br /> Effective:2013 July Ol <br /> Updated:2013 June <br /> � <br /> �. <br /> � <br />