Laserfiche WebLink
GENERAL NOTES: <br /> LEGEND <br /> 1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DR4WINGS. ADDITIDNAL NOiES MAY BE INDICATED <br /> ON INDIVIDUAL DRAWWGS. <br /> GENERAL SYMBOLS PIPING <br /> 2. DRAWINGS INDICAiE CONNECTIONS FOR EQUIPMENT TO BE FURNISHED BY THE OWNER OR AS THE <br /> WORK OF OTHER'RADES. VERIFY LOCATION OF EQUIPMENT, ROUGH-IN LDCATIONS, AND TYPE OF EXISTING UNDERGROUND PIPING —fl� BALL VALVE <br /> CDNNEC�IONS PRIOR TO PREPARATION OF SHOP DRAWINGS OR SUBMITTALS, AND PRIOR TO <br /> INSTALLATION OF SERVICE CONNECTIONS. DD NOT INiERFERE WIiH ACCESS �OR MAMTENANCE AND � <br /> REIAOVAL OR RtPLACEA�ENT OF EQUIPMENT. LIGHT LINE INDICATES AUTOMATIC CONTROL VALVE - THREE WAY <br /> EXISTING WORK (ELECTRIC OPERATOR SHOWN) <br /> 3. COORDINATE THE PHASING AND WSTALLATION OF NEW WORK WITH THE WORK OF ALL OTHER TRADES. ---- NEW UNDERGROUND PIPING � MANUAL, LOCKABLE CONTROL VALVE - THREE WAY <br /> BEAR THE TOTAL EXPENSE FOR ANY ADDITIONAL WORK WHICH MAY BE CAUSED BY IMPROPER <br /> SEQUENCING OF CONSiRUCTION ACTIVITIES. <br /> HFAVY LINE INDICATES —�� F�GE <br /> 4. REFER TO ARCHfTECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING, BUT NEW WORK <br /> NDT LIMITED TQ EqUIPMENT HOUSEKEEPING PADS, PENETRATION DEfAILS, FLASHING AND SEALING �I� UNIDN <br /> DEfAILS, AND OTHER ELEMENTS OF GENERAL CONSIRUCTION. COORDINATE THE SIZE AND LOCATION OF EXISTING WORK <br /> 55;'r,'t<� fi TO BE REMOVED <br /> EOUIPMENT HOUSEKEEPING PADS WITN APPROVED E4UIPMENT SO THAT HOUSEKEEPING PADS ARE � ?U�1P <br /> NOMINALLY 4" HIGH UNLESS INDICATED OTHERWISE, AND EXTEND 6" MINIMUM IN ALL DIRECTIONS Q FLAG NOTE <br /> FROM THE HORIZDNTAL LIMITS OF THE EQUIPMENT WHICH THEY SUPPORT. �� PIPING DOWN <br /> 5. COORDINATE EQUIP�IENT PDWER CONNECTION REQUIREMENTS AND ELECTRICAL CHARACTERISTICS WITH NUMBER INDICATWG DETAIL <br /> ELECiRICAL DRAWINGS AND CONNECTION REQUIREMENTS. COORDINATE VARIATION W ELECTRICAL � DEfAIL IDEKTIFICATION —� ?IPE CAP <br /> CHARACTERISTICS FRON SCHEDULED VALUES. CHANGES TO ELECTRICAL CHAR4CTERISTICS (E.G. M3 Ma <br /> VOLTAGE, AMPS, HORSEPOWER, EfC.) SHALL BE SUBJECT TO APPROVAL. BEAR THE TOTAL EXPENSE _�SHEEf NUMBER WHERE ABBREVIATIONS <br /> FOR REQUIRED REVISION TO THE ELECTRICAL SCOPE OF WORK CAUSED BY VARIA?ION FROM THE DEfAIL IS DRAWN <br /> SCHEDULED R�QUIRE�IENTS. <br /> SHEET NUMB�R WHERE (E) EXISTING <br /> D^TAIL IS TAKEN <br /> 6. EQUIPMENT SHORT CIRCUIT CURRENT RATINGS (SCCR) SHALL BE NOT LESS THAN THE INTERRUPTING EBS EMU�SION BREAKING SYSiEM <br /> RATING Of THE BRANCH CIRCUIT OVERCURRENT PROTECTNE DEVICE SUPPLYING POWER TO THE IW INDUSTRIAL WASTE <br /> EQUIPMENT. REFER TO ELECIRICA_SCHEDULES FDR BRANCH CIRCUIT OVERCURRENT DEVICE O NORTH ARROW <br /> INTERRUPTING RAiINGS. OW OILY WASTE <br /> 7. COORDINATE THE LOCATIDN OF WORK TO PROVIDE CLEARANCES OVER LIGHTING FlXTURES AND OTHER PIW PUMPED INDUSTRIAL WASTE <br /> CANOPY MDUNTED DEVICES AS REQUIRED T�ALLDW FOR REMOVAL AND MAINTENANCE ACCESS. POC POINT OF CONNECTION <br /> 8. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES AND EQUIPMENT AS SPECIFlED, AS SD STORM DRAIN <br /> R�4UIRED, AND AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION OF PIPES AND SS SANITARY SEWER <br /> EQUIPMENT, DESIGN AND PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND <br /> STRUCTURAL fRAME TO MEEf SUPPORT AND SEISA�IC RESTRAINT REACTIONS (FORCES, MOA�ENTS, INSTRUMENTATION <br /> DERECTIONS). STRUCTURAL MEMBERS AND ANCHORAGES SHALL BE DESIGNED BY A PROFESSIONAL <br /> ENGI4EER UCENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. REFER TO STRUCTURAL <br /> DRAWINGS FOR DESIGN CRffERIA. SUBMIT STRUCTURAL MEMBER SHOP DRAWINGS AND CALCULATIONS FM FLOW MEfER <br /> FOR REVIEW. STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORCANCE WITH THE <br /> REQUIREMENTS SHOWN ON THE STRUCTURAL DRAWINGS AND INDICATED IN THE SPECIFICATIONS. NO pH pH SENSOR <br /> WELDING, BOLTING, OR OTHER MEANS OF ATTACHMENT TO THE STRUCTURAL MtMBERS SHALL BE MADE <br /> ON PORTIONS OF STRUCTURAL MEMBERS AT OR NEAR CONNECTIONS BEfWEEN STRUCTURAL MEMBERS FPT FREEZE PROTECTION IMMERSION HEATER <br /> ON ANY ELEM�NTS DESIGNATEC IN THE SEISMIC LOAD RESISTING SYSTEMS UNLESS APPROVED BY THE <br /> STRUCTURAL ENGI4EER. SUPPORTS SHALL NOT INDUCE TORSIONAL LOADS INTD SUPPORTING <br /> STRUCTURAL FRAM!NG. CR CONTROL RELAY <br /> 9. COORDINATE THE LAYOUT OF EQUIPMENT, PIPING, AND APPURTENANCES SO THAT IT RTS INTO THE AO ALARM <br /> SPACE ALLOTTED. PROVIDE SERVICE ACCESS AND CLEARANCES AS INDICATED ON DRAWINGS, AS <br /> REOUIRED BY CODES, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE INSTALL4TION,REMOVAL, <br /> ENTRY, SERVICING, AND MAINTENANCE OF EQUIPMENT. PRIOR TO INSTALLATION,CODRDINATE LAYOUT OF OT THERMOSTAT <br /> EQUIP�AENT, PIPING, AND APPURTENANCES WITH ALL OTHER TR4DES TO AVOID BLOCKING SERVICE OR <br /> R�PLACENEN7 ACCESS FOR NEW AND EXISTING EQUIPMENT INSTALLED BY OTHERS. <br /> 10. DRAWINGS ARE DiAGRAMMATIC AND SHOW APPROXIMATE LOCATIONS OF EQUIPMENT, PIPING, AND <br /> APPURTENANCES. DRAWINGS DD NOT SHOW REQUIRED TRANSITIONS, OFFSEfS, FlTTINGS, AND DEVICES. <br /> REFER TO DEfAILS, DIAGRANS, AM1D SPECIFICATIONS FOR REQUIRED SYSTEM APPURTENANCES, CONTROL <br /> DEVICES, EfC. INSTALL DEVICES IN ACCORDANCE WITH DEVICE MANUFACTURER RECOMMENDATIONS. <br /> CAREFULLY INVESTIGATE ELEMENTS OF CONSTRUCTION THAT COULD AFFECT THE WORK TO BE <br /> PERFORMED AND ARRANGE NEW WORK ACCORDINGLY.PREPARE COORDINATION DRAWINGS FOR NEW <br /> g WORK, WHICH ARE COORDINATED WITH THE APPROVED AND INSTALLED WORK Of OTHER TRADES. <br /> � PROVIDE REQUIREC OFFSETS, FITf1NG5,TRANSITIONS, SUPPORTS AND OTHER APPURTENANCES AS <br /> E REQUIRED. BFAR THE TOTAL EXPENSE OF RE-WORK THAT IS CAUSED BY FNLURE TO COORDINATE. <br /> z <br /> 11. PROVIDE MAXIMUA� HEADROOIA AND CLEARANCE BELOW PIPING AND EQUIPMENT AND ASSOCIATED <br /> � SUPPORTS AND RESTRAINTS. WHERE WALL MOUNTED, INSTALL AS CLOSE TO WALL AS <br /> 3 POSSIBLEPROVIDE ADD'TIONAL FfTTINGS AND OFFSEfS AS REQUIRED. <br /> � 12 REFER TO EQUIP�IENT SCHEDULES FOR DESIGN CAPACITIES. SCHEDULED VALUES SHALL BE <br /> c CONSIDERED DESiGN CAPACITIES. PROVIDE EQUIPMENT WHICH MEETS OR EXCEEDS THE SCHEDULED <br /> < <br /> VAWES. MARK THE CONTR4CT DR4WING EQUIPMENT SCHEDULES TO IN�ICATE THE MANUFACTURER, <br /> N MODEL AND CAPAC(fY OF THE ACTUAL APPROVED EQUIPMENT PROVIDED AND SUBMIT THIS <br /> r INFORMATION WITH RECOR� DRAWINGS AS PART OF PROJECT CLOSEOUT. <br /> � <br /> � <br /> 0 13. TO ENHANCE THE CLARIiY OF PLAN �RAWINGS, AND WHERE NOT NECESSARY TO DESCRIBE THE <br /> � REQUIRED SIZE, INDIVIDUAL SEGMENTS OF PIPE BE�WEEN CONNECTIONS MAY BE SHOWN WITHOUT A <br /> � SIZE INDICATED. WHERE S!ZE IS NOT SHOWN DN PLANS, THAT SEGMENT SHALL BE THE SAME SIZE AS <br /> THE NEXT UPSTREAM SEGMENT WITH A SIZE INDICATED. <br /> � 14. WHERE NOT INDICATED ON PLANS, REFER TO EQUIPMENT SCHEDULES, DIAGRAMS, AND DEfAILS FOR <br /> - INLE�AND OUTLEf PIPE SIZES. <br /> � <br /> _ <br /> E _WOOd ae��<��°wa�aoa� c o . , �q��� g�'�- . �� �. COMMUNITY TRANSIT °'°"��,�. <br /> 3009 z n u= . . � ��'Y� �Q�1�--�—Q}/18/17 . . n A O.0 <br /> a � Y _ �t �'I'� B I D S ET T� �1eaz INDUSTRIAL WASTEWATER PRE—TREATMENT SYSTEMS �v' <br /> communit tCdt15 � �� KASCH PARK SITE �"""°'� <br /> � ��:� �- Har in�er w�ob.aboo°,�m � � , <br /> o� t 9 0 ;'��,�° .�s�`, r�, �fueuz <br /> = �� � R� � � ' ��^::=��° '�'�"°°" o'�,��`MECHANICAL GENERAL NOTES, LEGEND AND ABBREVIATIONS 3 '�T�, <br /> < — _- - -- — <br />