' • • <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Proj ect Info Project Title: Seaway Transit Center-Comfort Station Date 02/13/2017 <br /> Compliance forms Applicant Information. Provide contact information for individual who can For Building Department Use <br /> do not require a respond to inquiries about compliance form information provided. <br /> password to use. Company Name: IBI Group <br /> Instructiona/and Com an Address: <br /> ca/culating cells are p Y 801 Second Ave,Seattle WA 98104 <br /> write-protected. Applicant Name: Mark Millett <br /> Applicant Phone: 206 521-9091 <br /> Applicant Email: mark.millett@ibigroup.com <br /> Project Description ❑� New Building ❑ Addition ❑Alteration <br /> Occupancy Type � <br /> � All Commercial � Group R-All R1 and R2, R3, R4 over 3 stories � <br /> Selection required fo enable forms. <br /> Envelope Compliance Path � Prescriptive � Component Performance <br /> Selection required to enab/e forms. <br /> Component Performance O Standard � Change of Occupancy/Conditioning � <br /> Calculation Type <br /> Selection required to enab/e ENV-UA ❑ Additional Efficiency Package Option-C406.8 Enhanced Envelope <br /> and ENV-SHGC forms. To comply, demonstrate building thermal enve/ope performance is 15%lower than the Target UA. <br /> � Air barrier testing per Section C402.5.12 Q Air barrier testing not required <br /> included in project scope <br /> Air Barrier Testing � Additional Efficiency Package Option-C406.9 Reduced Air Infiltration <br /> To comply, demonstrate that measured air leakage of building envelope does not exceed 0.25 <br /> cfm/ft2(air barrier surface area)under test pressure of 0.3 inch w.g. <br /> Vertical Fenestration and Total Vertical Gross Exterior <br /> Skylight Area Calculation Fenestration Above Grade %Vertical <br /> (rough opening) divided by Wall Area times 100 equals Fenestration <br /> Prescriptive Path-Enter va/ues for <br /> vertical fenestration, skylights, gross walls 3 4 . 7 _ 12 0 7 . 4 )( �QQ — 2 . 9$s <br /> and roof on this ENV-SUM worksheet. ' <br /> Component Performance-Enter va/ues Gross Exterior <br /> in ENV-UA and/or ENV-UA-GROUP-R Total Skylight divided by Roof Area times 100 equals %Skylight <br /> worksheet. These values auto-fill from <br /> ENV-UA and are write-protected on ENV- O . O — S27 . O )( ��� — � . �$ <br /> Vertical <br /> Fenestration VERTICAL FENESTRATION AREA COMPLIES <br /> Fenestration Area Compliance Area <br /> Skylight Area SKYLIGHT AREA COMPLIES <br /> Vertical Fenestration � High performance fenestration U-factors and SHGC per C402.4.1.3 <br /> Alternates 0 Dedicated outdoor air system per C402.4.1.4 and C403.6 <br /> Show locations of qualifying daylight zone O In buildings>_3 stories, 25%or more of NET floor area is in daylight zones per <br /> areas and ft2 on project plans. <br /> O In buildings<3 stories,50%or more of CONDITIONED floor area is within daylight zones per <br /> For Daylight Zone Area Calculations- C402.4.1.1 <br /> a)Sidelight areas include primary+ Daylight Zone Calculations <br /> secondary daylght zone areas. Daylight Zone Fenestration Alternate Sidelight Daylight Toplight Daylight Percent Daylight <br /> b)Include overlapping toplight and Not Selected. No Calculations Required Zone Area Zone Area Zone Area <br /> sidelight daylight zone areas under <br /> Toplight. <br /> c)Refer to Chapter 2 for net floor area <br /> Spaces in Single Story List all enclosed spaces that exceed 2,500 ftz, have ceiling height greater than 15 ft, and are space <br /> Building Requiring Skylights types required to comp/y with this provision. <br /> Code requires a minimum of 50%of the f/oor Space Area(ft2) DLZ Area(ftZ) SRR or Aperature Exception <br /> area to be within a skylight daylight zone for <br /> snar.ifir..cnar.P tvna.c Rafar tn C;4lJ�4�fnr <br />