� � � � � � � � ■ <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Seaway Transit Center-Comfort Station Date 02/13/2017 <br /> Fenestration Area as%gross above-grade wall area 2•9� Max.Target: 30.0$ For Building Department Use <br /> Skylight Area a5%gross roof area Max.Target: 3.0$ <br /> If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1,then the project must compl <br /> via Component Performance and provide ENV-UA and ENV-SHGC forms. <br /> Buildin COIll onent R-Value Method for U-Factor/F-Factor Method for <br /> g p Prescriptive Compliance Prescriptive Compliance <br /> Perim. Ins. Full Slab CI <br /> Provide plan/detail#of assembly and description R-Value R-Value F-Factor F-Factor Source'o <br /> � DETAIL 2/A2.5 <br /> � L 2"RIGID INSULATION 24"AT PERIMETER 10.0 I <br /> m � <br /> c <br /> o -o <br /> � � <br /> m m <br /> � = I <br /> ns. ssem y <br /> Provide ID from door schedule and description R-Value U-Factor U-Factor Source" <br /> N �' DOORS 001-004 <br /> o .a' SOLID CORE � <br /> o � , <br /> a� <br /> � i <br /> 6 L <br /> N N <br /> a � <br /> O Q <br /> Solar Heat Gain Coefficient(SHGC) U-Factor for Prescriptive Compliance <br /> ro�ec ion rien a ion <br /> Factor(PF) (N or Assembly Assembly <br /> Provide ID from wlndow schedule and description if applicable12 SEW)13 SHGC14 U-Factor U-Factor Source" <br /> @ 6 GLASS BLOCK FRAME UNITS-20"X20" SEW 0.40 <br /> � I <br /> � <br /> c ' <br /> Z I <br /> o � 4 DOOR TRANSOM UNITS-36"X18" N ! 0.40 ' <br /> � ,x <br /> w - <br /> N (6 <br /> C C� <br /> � G <br /> (0 Q <br /> U p <br /> r — <br /> � � <br /> N <br /> � <br /> � <br /> N I <br /> � <br /> y � <br /> L n <br /> � T I <br /> � <br /> Y — I <br /> (� Q I <br /> Note 1-Insulation that is continuous except for fasteners may be entered here if the cross-sectional area of ineta/penetration through otherwise <br /> continuous insulation is/ess than 0.12%. <br /> Note 2-Alternate prescriptive continuous insulafion R-values per Table C402.1.4,Footnote F inay be used if the cross sectional area of inetal <br /> penetrations exceeds 0.04%but is less than 0.12%. Calculations are required to use these alternate R-values. <br /> Note 3-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. Specify the <br /> table number or calculation page number. <br /> Note 4-Thermal spacer blocking and liner system are required for prescriptive R-Value compliance in metal building roof assemblies. <br /> Nofe 5-Intermediate framing is required for prescriptive R-Value compliance in wood-framed wall assemblies. <br /> Note 6-Proposed CMU mass walls in non-Group R that meet Tab/e C402.1.4 Footnote D requirements can enter the target prescriptive <br /> U-va/ue of 0.104. <br /> Note 7-Mass transfer slab edges must be covered with an assemb/y having an overal U-factor of 0.2. <br /> Note 8-Refer to Table C402.1.3.Footnote E for prescriptive R-Value requirement for stee/floor joist assemblies. <br /> Note 9 -Prescriptive s/ab-on-grade insulation shall extend from top of slab to minimum length per an approved method as defined in C402.2.6. <br /> Nofe 10-Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 11-Opaque door U-factors sha/l come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 12-Refer to Equation C4-6 Projection Factor Calculation. <br /> Note 13-N=Oriented within 45 degrees of true north, SEW=All other orientations. <br /> Note 14-Fenestration assembly U-Factor and SHGC shall be the manufacturer's NFRC product rating, which includes the glazing and frame, or <br /> shall be the default value per Section C303.1.3. <br /> Note 15-List all above-grade Group R mass walls and steel frame wal/s in Group R Walls section. List commercia/above grade walls and all other <br /> Group R above grade walls in Opaque Walls-Above Grade. <br />