Laserfiche WebLink
• • • � ' • � • • � <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Seaway Transit Center-Comfort Station Date 02/13/2017 <br /> Fenestration Area as%gross above-grade wall area Z•9� Max.Target: 30.0$ For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0$ <br /> Building Component Proposed UA Target UA <br /> Ins.R Plan/Detail# F-factor Source&Table#8 F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> � R= 0.540 <br /> � L R= Slab-On-Grade F-0.54 <br /> `o> _ <br /> c � R <br /> ° -o R= 0.550 <br /> � � <br /> � � R= Heated Slab-On-Grade F-0.55 <br /> 2 R= ! <br /> Schedule ID U-factor Source910 U-factor x Area(A) =UA(U x A U-factor x Area(A)= UA(U x A) <br /> � I 0.37 <br /> o, Opaque Swing Doors U-0.37 <br /> c <br /> � <br /> � � <br /> `o <br /> 0 <br /> O 0.34 <br /> � <br /> L Opaque rollup&sliding U-0.34 <br /> O <br /> � 0.30 <br /> � Non-Metal Frame U-0.30 <br /> c <br /> 0 <br /> Z <br /> � i i 0.38 <br /> c � Metal Frame,Fixed U-0.38 <br /> o — <br /> r- m <br /> m � <br /> N � <br /> N <br /> N a �.4� <br /> u- o <br /> � _ Metal Frame,Operable U-0.40 <br /> U �p <br /> C � <br /> � � <br /> °� �.60 <br /> f0 I Metal Entrance Door U-0.60 <br /> � I i <br /> °' I <br /> � <br /> N 0.50 <br /> L T All types U-0.50 <br /> O7 F <br /> T — <br /> � Q <br /> Area UA Area UA <br /> Page 2 Subtotal <br /> TO COMPLY-The Proposed Total UA shall not Page 7 Subtotal <br /> exceed the Target Total UA. Project Total <br /> Component Performance Compliance (UA) <br /> Note 1-!f vertical fenestration or skylight area exceeds maximum allowed per C402.4.l. then Target Area Adjustment of all applicable envelope <br /> elements will be calculated automatica/ly by the compliance form. Refer to Target Area Adjustments worksheet for this ca/cu/ation. <br /> Note 2-Opaque assemb/y U-factors shall come from Appendix A or calcu/ated per approved method as specified in C402.1.5.1. <br /> Note 3-Proposed CMU mass wall in non-Group R that meet Tab/e C402.1.4 Footnote D requirements can enter the target U-value of 0.014 <br /> Note 4-For semi-heated spaces utilizing the wall insulation exception, enter Target Wall U-factors under Proposed Wall U-factors so exterior <br /> walls are neutral to the calcu/ation. <br /> Note 5-Mass transfer s/ab edges musf be covered with an assemb/y having an overa/U-factor of 0.2. <br /> Note 6-Demising wal/s, doors,and vertical fenestration separating spaces with different degrees of space conditioning(unconditioned, semi-heated, <br /> fully conditioned)shall be inc/uded only on the ENV-UA form for the space with the greatest degree of space conditioning. <br /> Note 7-List Group R above grade mass walls here. List all other mass walls, Commercial and Group R,in the Opaque Wa/ls-Above Grade section. <br /> Note 8 -Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 9 -Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 10-Fenestration assembly U-Factors shall be the manufacturer's NFRC product rating, which includes the glazing and frame, or shal/be <br /> the default value per Section C303.1.3. <br /> �� � �'7 �� <br />