My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3402 MCDOUGALL AVE SNO CO PW 2018-11-14
>
Address Records
>
MCDOUGALL AVE
>
3402
>
SNO CO PW
>
3402 MCDOUGALL AVE SNO CO PW 2018-11-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2018 1:07:59 PM
Creation date
5/23/2018 9:44:36 AM
Metadata
Fields
Template:
Address Document
Street Name
MCDOUGALL AVE
Street Number
3402
Tenant Name
SNO CO PW
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • � � . � � . � • � � <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> ProjectTitle: McDougall Date 2/26/2017 <br /> Calculation Q Q Addition - Q Addition For Building Department Use <br /> Area"oTE 9 stand alone +existing <br /> O Spaces where<50%of O Spaces where?50%of O <br /> luminaires are replaced luminaires are replaced <br /> L'PE� � Standard Q Additional Effciency Package Option Q <br /> Calculation C406.3 Reduced Interior Lighting <br /> To comply with C406.3, the Proposed LPD shall be 25%lovser than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage"oTE, <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height"orE z Area in f� Watts per ftz (watts/ftz x area) <br /> Warehouse Warehouse:Smaller,hand carried items 9.5 2604 0.760 1979 <br /> Meeting Room Conference/meeting/multipurpose 9.5 10� 0.980 106 <br /> Total Are 2712 <br /> Retail Display Allowance from LTG-INT-DISP <br /> Lobby ANExhibit Display Allowance from LTG-INT-DISPLA�TE� Allowed Watts 2085 <br /> Proposed Lighting Wattage"°TE` <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture DescriptionNore a,s,s Fixtures FixtureNorE� Proposed <br /> Warehouse LED Linear Industrial Surface Mount 43 42 1806 <br /> Meeting Room LED Linear Industrial Surface Mount 2 42 84 <br /> Proposed Retail Display Lighting from LTG-INT-DISP Y <br /> Total Proposed Watts may not exceed Total Allov�.ed Watts for Interior Lighting Total Proposed Watt 18 90 <br /> Interior Lighting Power Allowance <br /> Note 1-List all unique space types per Table C405.4.2(2)that occurin the project scope.Select space type category per from drop down menu. <br /> Nofe 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exemptlighting equ(pment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of/amps in the fixture, and ballast type(if included). <br /> For <br /> track lighting, list the length of the track(in feet)in addition to the fixture,lamp, and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1, note exception number and/eave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage tab/e in the same manner as new fixtures.Identify as <br /> existing <br /> in fixture description. <br /> Note 7-Forproposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp v✓attage). For low <br /> voltage <br /> lighting, enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached/uminaire wattage or <br /> 50 <br /> watts/lineal foot, or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> �/��.:. J d <br />
The URL can be used to link to this page
Your browser does not support the video tag.