Laserfiche WebLink
• • � � . � � . � • � � <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> ProjectTitle: McDougall Date 2/26/2017 <br /> Calculation Q Q Addition - Q Addition For Building Department Use <br /> Area"oTE 9 stand alone +existing <br /> O Spaces where<50%of O Spaces where?50%of O <br /> luminaires are replaced luminaires are replaced <br /> L'PE� � Standard Q Additional Effciency Package Option Q <br /> Calculation C406.3 Reduced Interior Lighting <br /> To comply with C406.3, the Proposed LPD shall be 25%lovser than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage"oTE, <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height"orE z Area in f� Watts per ftz (watts/ftz x area) <br /> Warehouse Warehouse:Smaller,hand carried items 9.5 2604 0.760 1979 <br /> Meeting Room Conference/meeting/multipurpose 9.5 10� 0.980 106 <br /> Total Are 2712 <br /> Retail Display Allowance from LTG-INT-DISP <br /> Lobby ANExhibit Display Allowance from LTG-INT-DISPLA�TE� Allowed Watts 2085 <br /> Proposed Lighting Wattage"°TE` <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture DescriptionNore a,s,s Fixtures FixtureNorE� Proposed <br /> Warehouse LED Linear Industrial Surface Mount 43 42 1806 <br /> Meeting Room LED Linear Industrial Surface Mount 2 42 84 <br /> Proposed Retail Display Lighting from LTG-INT-DISP Y <br /> Total Proposed Watts may not exceed Total Allov�.ed Watts for Interior Lighting Total Proposed Watt 18 90 <br /> Interior Lighting Power Allowance <br /> Note 1-List all unique space types per Table C405.4.2(2)that occurin the project scope.Select space type category per from drop down menu. <br /> Nofe 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exemptlighting equ(pment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of/amps in the fixture, and ballast type(if included). <br /> For <br /> track lighting, list the length of the track(in feet)in addition to the fixture,lamp, and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1, note exception number and/eave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage tab/e in the same manner as new fixtures.Identify as <br /> existing <br /> in fixture description. <br /> Note 7-Forproposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp v✓attage). For low <br /> voltage <br /> lighting, enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached/uminaire wattage or <br /> 50 <br /> watts/lineal foot, or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> �/��.:. J d <br />