Laserfiche WebLink
• • • • . � • . � � � � <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2.R3.R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Seaway Transit Center Date 12/19/2016 <br /> Calculation � p Addition - 0 Addition For Building Department Use <br /> NOTE 9 stand alone +existing <br /> Area � Spaces where<50%of Q Spaces where>_50%of 0 <br /> luminaires are replaced luminaires are replaced <br /> L'P`� ! Standard � Additional Efficiency Package Option Q <br /> Calculation C406.3 Reduced Interior Lighting <br /> To comply with C406.3. the Proposed LPD shall be 25%lovtier than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage"°TE, <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room# S ace T e Hei htNore z Area in f� Watts er ft2 watts/ftZ x area <br /> RESTROOM Restroom:all other 9 270 0.780 211 <br /> MAINTENANCE Workshop 9 138 1.270 175 <br /> KITCHEN Lounge/breakroom:all other 9 35 0.580 20 <br /> Total Are 443 <br /> Retail Display Allowance from LTG-INT-DISPL <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLA�TE� Allowed Watts 406 <br /> Pro osed Li htin Watta F NOTE 3 <br /> Location(plan#, Number of Watts/ Watts <br /> room# Fixture Descri tionNorE a,s,s Fixtures FixtureNorE� Pro osed <br /> RESTROOM L2 6 45 270 <br /> MAINTENANCE L1 2 45 90 <br /> KITCHEN L2 1 45 45 <br /> Proposed Retail Display Lighting from LTG-INT-DISP Y <br /> Total Proposed Watts may not exceed Tota!Allov�ed Watts for Interior Lighting Total Proposed Watts 4 O5 <br /> Interior Li htin Power Allowance <br /> Note 1-List all unique space types per Table C405.4.2(2J that occur in the project scope.Se/ect space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exemptlighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture, and ballast type(if included). <br /> For <br /> track lighting, list the length of the track(in feet)in addition to the fixture,lamp, and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shal/be included in the Proposed Lrghting Wattage table in the same manner as new fixtures.Identify as <br /> existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input�ttage of the fixture(not the lamp v✓attage). Forlow <br /> voltage <br /> lighting, enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or <br /> 50 <br /> v✓attsAineal foot. or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allov�ed Lighting Wattage. <br /> Note 9-Calculation Area Detai/s: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building <br /> linhtinn.Sv.ttPm.t t�rlamnn.strata r.mm�/ianr.a Rafar in C;5(J�1 <br /> �� � yIr <br /> ��_, <br />