. <br /> • � • <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Seaway Transit Center Date 12/19/2 016 <br /> Exterior Lighting For Building Department Use <br /> � Zone 1 p Zone 2 Q Zone 3 lZone 4 <br /> Zone Table C405.5.2(1) <br /> Specified by junsdiction. Zone selection required to enable LTG-EXT form <br /> Calculation Area � d Addition- � Addition <br /> stand alone +existing <br /> � Alteration with <50% 0 Alteration with >_50%ext. <br /> ext. wattage replaced wattage replaced <br /> Building Grounds p Effcacy>80 lumens/watt � Exemptio <br /> Appliesto luminaires> <br /> 100 Watts 0 Controlled by motion sensor <br /> Tradable Maximum Allowed Lighting Wattage"oTE, Base site Allowance: �s o0 <br /> Area( ),perimeter(I � <br /> Tradable Surfaces Surface Description or#of items per fi2 or per If x ftz(or x If) <br /> Uncovered Parking and drives BUS DRIVE LANE 114800 0.10 W/ft2 11480 <br /> GroundsWalkways >10'wide WALKWAYS 20500 0.20 W/ft2 4100 <br /> Entry Canopies FULL SHLETER 2160 0.4 W/ft2 864 <br /> Entry Canopies NARROW SHELTER 240 0.4 W/ft2 96 <br /> Entry Canopies ENTRY CANOPY 3 0 0 0.4 W/f t 2 12 0 <br /> Entry Canopies COMFORT STATION 192 0.4 W/ft2 77 <br /> Total Allowed Tradable+Site Allowance Watt : 18037 <br /> Tradable Proposed Lighting Wattage"oTE 2 <br /> Number of a s per Watts <br /> Tradable Surface Fixture DescriptionNOTE 3.a Fixtures FIXlUf6NOTE 5 proposed <br /> Uncovered Parking and drives L5 14 213 2982 <br /> Uncovered Parking and drives L7 6 528 3168 <br /> Grounds Walkways >10'wide L4 35 50 1750 <br /> Entry Canopies L6A(FULL SHLETER)7 EACH 35 56 1960 <br /> Entry Canopies L6A(NARROW SHELTER)4 EACH 8 56 448 <br /> Entry Canopies L9(ENTRY CANOPY) 4 54 216 <br /> Entry Canopies L10(ENTRY CANOPY) 7 33 231 <br /> Entry Canopies L3(COMFORT STATION) 3 40 120 <br /> Total proposed tradable vietts may not exceed the sum of total allo�ed tradable Total Proposed Tradable Watts 10875 <br /> �netts plus the base site allo�nence. Any base site allovtiance not needed to <br /> make tradable�tts comply can be applied to individual non-tradable <br /> Non-Tradable Maximum Allowed Lighting Wattage"oTE, SiteAllowance Remaining: 1300 <br /> Area( ), perimeter(If owe atts AI owe atts <br /> Non-Tradable Surfaces Surface Description or#of items per ftz or per If x flz(or x If) <br /> Non-Tradable Proposed Lighting Wattage"oTE` <br /> Number of a s per Watts <br /> Non-Tradable Surface Fixture DescriptionNOTE 3,a Fixtures FixtureNOTE 5 Proposed <br /> Non-tradable proposed�etts may not exceed allo�ned�etts for any individual Non-Tradable Watts Exceeding LPA: 0 <br /> surface unless the total excess v�etts for all non-tradable surtaces are/ess than <br /> the remainingsite allo�ence. Remaining Site Allowance: 1300 <br /> Exterior Lighting <br /> Note 1-List all unique exterior sufaces per Table C405.5.2(2)that occur in the project scope. Select extenor surface categories from drop <br /> dov�n menu. <br /> Note 2-List all proposed/ighting fixtures inc/uding existing-to-remain fixtures. <br /> Note 3-For pr000sed Fixture Descnption.indicate fixture tvoe. lamo tvoe. number of lamps in the fixture. and ballast tvQe(if apolicablel. <br />