Laserfiche WebLink
Model 1011T <br /> TESTANDRAIN® <br /> Sectional Floor Control Test and Drain Valve with Pressure <br /> Gauge for Systems Requiring Pressure Relief Valve <br /> Sizes: ;u 175 <br /> , <br /> 3/4" 1" 11/4" 11/2 2" J 75° ., • <br /> 50 w t5• <br /> 25 775 <br /> The AGF Model 1011T TESTANDRAIN' ® w.:E, � . <br /> provides the test and express drain functions • <br /> for wet fire sprinkler systems on multi-story <br /> installations requiring pressure relief (NFPA <br /> 13 and NFPA 13R). The Model 1011A fea- <br /> tures a Model 7000 Pressure Relief Valve <br /> with drain pipe, 31/2" Model 7500 Pressure <br /> Gauge and 3-Way Globe Valve. TEST 43, <br /> The Model 1011T is available in a full range " R <br /> of sizes (3/4" to 2") with NPT connections • ' •, <br /> tl. O f it <br /> (BSPT available).The Model 7000 Pressure <br /> Relief Valve (UL/FM) features a flushing ® <br /> handle and a 175 PSI factory rating (other <br /> pressure ratings available). )•)-2:)7 WAY/ • <br /> • Complies with NFPA 13 Requirements <br /> • Compact, Single-Handle Ball Valve <br /> • Tamper-Resistant Test Orifice and Sight Glasses <br /> • 300 PSI rated. <br /> • Specifiable orifice sizes:3/8" (2.8K), 7116" (4.2K), 1" (5.6K), 17/33" (8.0K), 5/6" (11.2K, ELO), 3/4" (14.0K, ESFR), and K25 <br /> • Relieves Excess System Pressure caused by Surges or Temperature Changes <br /> • Includes Model 7500 Pressure Gauge and UL/FM Model 7600 Globe Valve <br /> • Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing <br /> • Locking Kit Available <br /> Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), <br /> Stem Packing (1), and Stem Washer(1). Valve and orifice size must be specified when ordering. <br /> NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. <br /> Standard relief valves are required to OPEN in a range of pressure between 90%and 105%of their rating.The valves are required to CLOSE at a pressure <br /> above 80%of that rating.The relief valve should be installed where it is easily accessible for maintenance.Care should be taken that the relief valve CANNOT <br /> be isolated from the system when the system is operational.A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. <br /> Reliability, Versatility, Code Compatibility <br /> SS-M1011T_V001 06/13 TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. <br />