My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
824 W CASINO RD BLDG L 2018-10-10
>
Address Records
>
W CASINO RD
>
824
>
BLDG L
>
824 W CASINO RD BLDG L 2018-10-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2018 2:02:46 PM
Creation date
5/29/2018 9:30:04 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
824
Tenant Name
BLDG L
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Er-11l Code Compliance Forms for Commercial, R2 over 3 stories and all R1 <br /> Mechanical Fan System Power Allowance MECH-FANSYS <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> 'Project Title: Avaire Apartments Renovation Date 2/13/2017 <br /> A separate MECH-FANSYS form must be completed for every HVAC system that exceeds the 5 hp threshold. For Building Dept.Use <br /> Fan System ID <br /> System Supply Fan Constant Volume(CV), Variable Air <br /> y pp y Volume(VAV),or Hospital/Lab CV <br /> Speed Control system that qualifies for VAV budget per <br /> C403.2.11.1,Exception,1 <br /> Compliance is based upon either the fan motor nameplate horse power <br /> ComllariCe O tion (Option 1),the fan brake horsepower(Option 2),or C403.7 high efficieny <br /> p p VAV fan brake horsepower(10%less than Option 2).The bhp calculation <br /> provides adjustments for special equipment per Table C403.2.11.1(2). <br /> In Fan Equipment Schedule below,provide maximum design supply airflow <br /> rate(CFM)of all supply fans serving the conditioned space in Fan <br /> Equipment Schedule below.Fan System CFM Total is the supply airflow of <br /> Fan System Supply the central air handler at peak design conditions.Additional volumetric air <br /> CFM Total - flow provided at zone fan terminals,booster fans,or through induction is <br /> not included in the supply CFM total.However,the fan power of this <br /> equipment is included in the HP and BHP calculations.Fan System <br /> Supply CFM Total is automatically calculated by the form. <br /> Fan Equipment Schedule <br /> Total CFM Total Nameplate Total BHP <br /> Fan ID and Location ' Fan Type Quantity of Fan Type (Note 1) HP(Note 2) (Note 3) <br /> Note 1-Total CFM is the maximum CFM of the listed fan(s)when Total Proposed: I <br /> operating at peak design operating conditions. <br /> Note 2-Total namplate hp of the listed fan(s). Total Allowance: <br /> Note 3-Total brake horsepower(bhp)of the listed fan(s)at peak , <br /> design operating conditions. Not required <br /> if Nameplate HP compliance option chosen. Compliance Message: <br /> Brake Horsepower Allowance Adjustments <br /> Calculated <br /> Assigned Pressure Adjustment, <br /> CFM thorough this Pressure Drop, <br /> Device Type Description and Location Drop,PD in w.c. A in bhp <br /> device(CFMD) PD in w.c. <br /> (Note 6) (Note 8)7) <br /> Note 4-Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment(bhp): <br /> streams,so the CFMD is the sum of the supply CFM and exhaust CFM if both go through <br /> the device. <br /> Note 5-Energy recovery effectiveness is defined as change in the enthalpy of the outdoor air supply <br /> divided by the enthaply difference between the outdoor air and return air at design conditions. <br /> Note 6-Assigned pressure drop(PD)adjustment per Table C403.2.11.1(2). <br /> Note 7-Pressure drop(PD)adjustment shall be calculated per the applicable method <br /> defined in Table C403.2.11.1(2)based on specific system conditions. <br /> Note 8-A=PD*CFMD/4131 where A is the allowed system brake horse power <br /> adjustment,PD is pressure drop allowance,and CFMD is the cfm through the device. <br />
The URL can be used to link to this page
Your browser does not support the video tag.