PARTS LIST <br /> iTEM QTY. PART N0, MANUFACTURER DESCRIPTIDN . <br /> 1 1 CSD302412 HQFFMAN Wall-Mount Type 4/12 Enclosure 30A�x24.00x12.00in <br /> 2 1 CP3024 HOFFMAN Panel, 28.20x22.20 <br /> 2 '� 3 1 194R-NU30-1753 AB 30AMP Non-Fused Disconnect <br /> 20 . 3 � <br /> 3 1 194R-S1 AB Disconnect Shaft (12") <br /> ��. .� 4 1 194R-PY AB Disconnect Handle <br /> 5 1 20F11 ND�22AAONNNNN AB Drive, 753 Series, 7.5HP <br /> � <br /> 5 1 20-HIM-C6S AB Door Mounted HIM <br /> 5 � 20-750-2262G2R AB Network Communications Option Module <br /> F 'rs 1 5 1 20-750-2000MM AB Communication Carrier Cards <br /> 5 1 20-COMM-H AB HVAC Communication MODBUS RTU <br /> 1 � 1 6 1 ISG-KPC-AB-C6S ISG HIM Keypad Protection Cover <br /> � � � � � ITTAL Fan-and-filter unit 115 V 50/60 Hz <br /> 1 q. 7 1 3239.110 R , , <br /> 2 Q Q 2 8 1 3239.200 RITTAL �utlet filter <br /> 2 a o 2 9 1 3110.000 RITTAL Fan Thermostat <br /> 17 3 O 3 10 1 E500WB SOLA Transformer, SBE - 2401480Pri to 120VSec <br /> O � � MERSEN 3AMP Class "CC" Time Dela Fuse 600V <br /> 1 5 10 2 ATQR3 <br /> 4 � �i � 4 y � <br /> 10 1 TRM6 MERSEN 6AMP Midget Time Delay Fuse, 250V <br /> � � 5 5 11 1 2$1-611/281-418 WAGO 8MM Fused(5x20mm) TB 110/220VAC 6.3Amp Indicating <br /> � � � <br /> '� $ 6 � � � 6 12 1 281-311 WAGO 8MM Fused Terminal Block End Cover <br /> 7 7 13 1 GSC2 MERSEN 2AMP Slow Acting Fuse <br /> 0 � � 14 1 281-631 WAGO Gray 6MM Terminal Block 30A (3-Conductor) <br /> 8 O � � 8 15 1 281-312 WAG� Gray 6MM & 8MM End Section (3-Conductor) <br /> g O � � g 16 37 281-601 WAGO Gray 6mm Terminal Block 30A <br /> 10 Q 10 17 1 281-316 WAGO Gray 6MM & 8MM End Section <br /> � � 1 g 6 281 402 WAGO Ad�acent Jumper . <br /> 11 Q � � 11 �g 4 249-117 WAGO End Anchor <br /> � � � 12 O 12 20 AIR STANDARD ANY 35MM Din Rail <br /> 0 � <br /> 8 � 13 � � a 13 21 2 1492-GM35 AB Group Marlung Carner _ <br /> 22 1 281-637 WAG4 Ground Terminal Block(3 Conductor) <br /> 14 a � O 14 23 1 281-313 WAGO 4range Cover �3-Cond�uctor) <br /> 15 O � � 15 24 AIR F1x2WH6 PANDUIT White Wireduct 1"x2" High <br /> N b, z � 16 O � � 16 24 AIR C1WH6 PANDUIT White Cover 1" <br /> 20 � �,.. 25 A/R F1x2LG6 PANDUIT Light Gray Wireduct 1"x2" High <br /> 1— 17 � � O �7 <br /> 25 A/R C1LG6 PANDUIT Light Gray Cover 1" <br /> � � 18 O Q 18 26 1 RL-01202 MTE LINE REACTOR, 3% Impedance, 7.5HP , <br /> F � � <br /> �9 O � �9 27 1 2AS2-3 ALTECH Black w/ White Knob Insert, 3-Position Sel Switch <br /> � � 20 20 27 4 S1 ALTECH NO Contact Block <br /> � � � 27 1 HW9Z-KL1 IDEG Selector Switch Guard <br /> � � � �1 21 <br /> � � � <br /> 22 � � � 22 <br /> 23 � � � 23 <br /> 24 � � � 24 <br /> 25 � � 0 25 <br /> � 26 Q � Q 26 <br /> 27 O � � 27 <br /> 19 �8 28 <br /> � � � <br /> 11 2 2 29 0 � 0 29 � <br /> 300 � o �o <br /> 31 O O 31 <br /> 12 32 � � �� <br /> 23 <br /> 33 O � 33 <br /> 34 � � 34 <br /> 1 � 35 O O 35 <br /> 35 O � 35 <br /> � <br /> 19 <br /> 2 BOEING VFD Ct�NTR4L PANEL BaM & TB DETAIL <br /> - SCALE: NTS <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAwN DATE SUBTITIE CURRENT REVISION SYMBOL Dnr� <br /> ACCEPTABII.ITY s�o 0525.17 CHILLER 1 CHWSP VFD BOM &TB DETAfL 2a999�g� NEW o5.25." <br /> THISDESIGNANDIdR CHECKED <br /> - - - - SPECIFICATION IS APPROVED sHE�r -��- <br /> �� ENGINEER TITLE �^- <br /> ���,� APPROVEDBY DEPT. DATE CH�ECI�R 05.25,�� E544� 1 � � o <br /> � <br /> �PRo�� B U I L D I N G 40�0�� • .IOB N0. COMP NQ � <br /> a <br /> m <br /> nPPRavEn ELECTRICAL MASTER EVERETT,WA °wc No. 40-Q41-E544-10-2 <br />