Laserfiche WebLink
1 <br />` i tnxTower Job Page <br /> Buzz Inn (BU 880407) 3 of 13 <br /> Tower Engineering Project Date <br /> Professionals,Inc. TEP No. 51358.131860 21:34:29 09/10/17 <br /> 326 Tryon Road <br /> Raleigh,NC 2 760 3-52 63 Client Designed <br /> Phone:(919)661-6351 Crown Castle g by <br /> FAX:(919)661-6350 pstewart <br /> Tower Tower Face AR AF CAAA CAAA Weight <br /> Section Elevation In Face Out Face <br /> ft ft2 ft2 ft2 ft2 K <br /> Ll 88.00-42.25 A 0.000 0.000 0.000 0.000 0.08 <br /> B 0.000 0.000 0.000 0.000 0.00 <br /> C 0.000 0.000 3.317 0.000 0.18 <br /> L2 42.25-0.00 A 0.000 0.000 0.000 0.000 0.11 <br /> B 0.000 0.000 0.000 0.000 0.00 <br /> C 0.000 0.000 3.063 0.000 0.17 <br /> Feed Line/Linear Appurtenances Section Areas - With Ice <br /> Tower Tower Face Ice AR AF CAAA CAAA Weight <br /> Section Elevation or Thickness In Face Out Face <br /> ft Leg in ft2 ft2 ft2 ft2 K <br /> Ll 88.00-42.25 A 0.534 0.000 0.000 0.000 0.000 0.08 <br /> B 0.000 0.000 0.000 0.000 0.00 <br /> C 0.000 0.000 13.094 0.000 0.23 <br /> L2 42.25-0.00 A 0.478 0.000 0.000 0.000 0.000 0.11 <br /> B 0.000 0.000 0.000 0.000 0.00 <br /> C 0.000 0.000 12.092 0.000 0.22 <br /> Feed Line Center of Pressure <br /> Section Elevation CPR CPZ CPR CPZ <br /> Ice Ice <br /> ft in in in in <br /> Ll 88.00-42.25 0.0000 0.1042 0.0000 0.3441 <br /> L2 42.25-0.00 0.0000 0.1049 0.0000 0.3615 <br /> Shielding Factor Ka <br /> Tower Feed Line Description Feed Line K. Ka <br /> Section Record No. Segment Elev. No Ice Ice <br /> Ll 1 Step Pegs(5/8"SR)7-in. 42.25-88.00 1.0000 1.0000 <br /> w/30"step <br /> Ll 2 Safety Line 3/8 42.25-88.00 1.0000 1.0000 <br /> Discrete Tower Loads <br />