Laserfiche WebLink
' Predator (3-12.5 Ton Package)YORK <br /> N524 <br /> • <br /> York Single Package R-410A Air Conditioner <br /> Project Name: 112th St Diner Unit Model#: ZF120N18R2B1GAA1A2 <br /> Quantity: 1 Tag#:End System: ZF120N18R2B1GAA1A2 <br /> Seismic Certification <br /> 725672-UAD-A-0911 <br /> SPECIAL SEISMIC CERTIFICATION <br /> ((s)) DCL Dinar icCe,,f,,,:,,n OF NON-STRUCTURAL Johnson <br /> Controls <br /> COMPONENTS AND SYSTEMS <br /> CERTIFICATE OF COMPLIANCE <br /> Dynamic Certification Laboratories has qualified the listed packaged rooftop units as CERTIFIED for seismic <br /> applications in accordance with the following codes and standards: <br /> CBC 2010, IBC 2009, ICC-ES AC-156 2010, ASCE 7-05 <br /> The following model designations are included in this certification. A complete list of certified models,options, <br /> and installation methods are detailed in report number 90300-1107 by Dynamic Certification Laboratories, <br /> provided by the equipment manufacturer upon request. <br /> Unitary Product Group Packaged Rooftop Units (UPG) <br /> Seismic Qualification Testing was conducted in accordance with and in strict adherence to the standards set <br /> forth within the American Society of Civil Engineers(ASCE 7)by the independent approval agency,Dynamic <br /> Certification Laboratories. The above referenced equipment is APPROVED for seismic applications when <br /> properly installed and used as intended. <br /> The basis of this certification is through testing of the active and energized components per AC156. This <br /> certification covers multiple UPG brands,including York,Johnson Controls,Coleman,Luxaire,Evcon,Fraser- <br /> Johnston and Ready Ship. <br /> The seismic values are obtained from the Maximum Considered Earthquake Short Period Spectral Response <br /> Acceleration,Sds,as determined by the ASCE 7 seismic maps. Various installation locations/isolation <br /> configurations are covered under this certification,limited by the Sds value stated in the following table. A <br /> seismic importance factor,Ip,of 1.5 applies to this certification to include essential facility requirements and life <br /> safety applications for post event functionality. The units are approved for both a 14"rigid and 22"spring isolated, <br /> seismically approved roof curbs,or slab(on grade)mount. <br /> Maximum Design Sds Values of UPG Packaged Rooftop Units <br /> Series Model Tons Sds(g) Fp/Wp <br /> ZR/ZJ/ZH/ZK/ZW/ZU/JA3* 037 3 2.5 1.88 <br /> ZR/ZJ/ZH/ZK/ZW/ZU/JA4* 049 4 2.5 1.88 <br /> ZR/Z1/ZH/ZK/ZW/ZU/JA5* 061 5 2.5 1.88 <br /> ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J06* 078 6.5 2.5 1.88 <br /> ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J07*/T* 090 7.5 2.5 1.88 <br /> ZR/Z1/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J08* 102 8.5 2.5 1.88 <br /> ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J 10*/T* 120 10 2.5 1.88 <br /> ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J12*/T* 150 12.5 2.0 1.50 <br /> Page 1of2 <br /> Dynamic Certification Laboratories 1315 Greg Street,Suite 109,Sparks,NV 89431—ph:775-358-5085 www.shaketest.com <br /> Johnson Controls Unitary Products 1 <br /> 77/0)1/ <br /> Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 08/04/2017 <br />