My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11114 EVERGREEN WAY RAZZALS SPORTS BAR 2018-06-01
>
Address Records
>
EVERGREEN WAY
>
11114
>
RAZZALS SPORTS BAR
>
11114 EVERGREEN WAY RAZZALS SPORTS BAR 2018-06-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2018 1:59:07 PM
Creation date
5/29/2018 1:56:15 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
11114
Tenant Name
RAZZALS SPORTS BAR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, ill Predator (3-12N524.5 Ton Package) Page: 11 <br /> yoRK <br /> York Single Package R-410A Air Conditioner <br /> Project Name: 112th St Diner Unit Model#: ZF120N18P2A1AAA1A2 <br /> Quantity: 1 Tag#:Side System: ZF120N18P2A1AAA1A2 <br /> Cooling Performance <br /> Total gross capacity 123.8 MBH l <br /> Sensible gross capacity 74.9 MBH l <br /> Efficiency(at ARI) 11.00 EER t" <br /> Integrated elf.(at ARI) 14.20 IEER -.i <br /> Ambient DB temp. 86.1 °F I ,: fi <br /> Entering DB temp. 80.0 °F ( » <br /> Entering WB temp. 67.0 °F <br /> Leaving DB temp. 53.3 °F l iy <br /> Leaving WB temp. 51.1 °F a �`:_ _ <br /> Power input(w/o blower) 8.29 kW • <br /> Sound power 92 dB(A) I <br /> Refrigerant � <br /> Refrigerant type R-410A - - <br /> Sys1 6 lbs 8 oz .•,•. <br /> Sys2 6 lbs 8 oz <br /> Gas Heating Performance <br /> Entering DB temp. 60 °F 10 Ton <br /> Heating output capacity(Max) 144 MBH • York Predator units are manufactured at an ISO 9001 registered facility and <br /> Supply air 26001CFM each rooftopis completely computer-run testedprior to shipment. <br /> Heating input capacity(Max) 180 MBH p y p p <br /> Leaving DB temp. 111.3 °F Unit Features <br /> Air temp.rise 51.3 °F <br /> SSE 80.0 % • Two Stage Cooling <br /> Stages 2 • 180 MBH Input Aluminized Steel,Two Stage Gas Heat <br /> Supply Air Blower Performance • Full perimeter base rails with built in rigging capabilities <br /> Supply air 2600 CFM • Either supply and/or return can be field converted from vertical to horizontal <br /> Ext.static pressure 0.6 IWG configuration without cutting panels. <br /> Addl.Unit Losses(Options/Accessories) 0.14 IWG • Unit Cabinet Constructed of Powder Painted Steel,Certified At 1000 Hours <br /> Blower speed 809 RPM Salt Spray Test(ASTM B-117 Standards) <br /> Max BHP of Motor(including service factor) 2.30 HP • Reciprocating Compressor <br /> Duct location Side • Slide-out Blower/2 HP Belt Drive Motor Assembly <br /> Motor rating 2.00 HP <br /> •Actual required BHP 1.07 HP Unit Ships with 2"Throwaway Filters <br /> Power input 0.99 kW • Solid Core Liquid Line Filter Driers <br /> Elevation 30 ft. • Replacement Filters:4-(24"x 20").Unit accepts 2"or 4"wide filters. <br /> Drive type BELT • Short Circuit Current:5kA RMS Symmetrical <br /> Electrical Data • Through-the-Curb and Through-the-Base Utility Connections <br /> Power supply 208-3-60 • Single Point Power Connection <br /> Unit min circuit ampacity 45.7 Amps • Micro-Channel"all-aluminum"condenser coil,Copper tube/aluminum fin <br /> Unit max over-current protection 60 Amps evaporator coil <br /> Dimensions&Weight • Composite Drain Pan-Front Connection <br /> Hgt 51 in. Len 89 in. Wth 59 in. • Hinged Access Panels <br /> Weight with factory installed options 1165 lbs. BAS Controller <br /> Clearances • IntelliSpeed control of the VFD based on stages of cooling.Provides Single <br /> Right 12 in. Front 36 in. Back 12 in. Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10. <br /> `Top 72 in. Bottom 0 in. Left 36 in. , • Simplicity SE Controller including Discharge Air,Return Air,and Outdoor Air <br /> Note: Please refer to the tech guide for listed maximum static pressures Temperature Sensors <br /> �(�p�[nn ev5 <br /> (/ Standard Unit Controller: Simplicity Control Board <br /> AMEPKA '"""'" per,n.*9 CERTIFIED..nUUITY� • Safety Monitoring-Monitors the High and Low Pressure Switches,the <br /> ,„„,. ,, coil' ITus i^_\T/ Freezestats,the Gas Valve,if Applicable,and the Temperature Limit Switch <br /> on Gas and Electric Heat Units.The Unit Control Board will Alarm on Ignition <br /> Failures,Safety Lockouts and Repeated Limit Switch Trips. <br /> • An Integrated Low-Ambient Control,Anti-Short Cycle Protection,Lead-Lag, <br /> Fan On and Fan off Delays,Low Voltage Protection,On-Board Diagnostic <br /> and Fault Code Display.Allows all units to operate in the cooling mode down <br /> to 0°F outdoor ambient without <br /> Warranty <br /> • One(1)Year Limited Warranty on the Complete Unit <br /> • Five(5)Year Warranty-Compressors and Electric Heater Elements <br /> • Ten(10)Year Limited Warranty-Aluminized Steel Heat Exchanger <br /> 40- <br /> ' <br /> Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 08/04/2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.