My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11114 EVERGREEN WAY RAZZALS SPORTS BAR 2018-06-01
>
Address Records
>
EVERGREEN WAY
>
11114
>
RAZZALS SPORTS BAR
>
11114 EVERGREEN WAY RAZZALS SPORTS BAR 2018-06-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2018 1:59:07 PM
Creation date
5/29/2018 1:56:15 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
11114
Tenant Name
RAZZALS SPORTS BAR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
yORIt <br /> Predator (342.5 Ton Package) Pager-4—. <br /> , ay° <br /> N524 <br /> York Single Package R-410A Air Conditioner <br /> Project Name: 112th St Diner Unit Model#: ZF120N18R2B1GAA1A2 <br /> Quantity: 1 Tag#:End System: ZF120N18R2B1GAA1A2 <br /> Cooling Performance _ <br /> Total gross capacity 135.3 MBH - !a4 ,"– <br /> Sensible gross capacity 96.4 MBH 1, ,'. '1YORK. <br /> Efficiency(at ARI) 11.00 EER i _ <br /> Integrated eff.(at ARI) 14.20 IEER – <br /> -. ,k <br /> Ambient DB temp. 86.1 °Fr <br /> Entering DB temp. 80.0 °Fiv . <br /> Entering WB temp. 67.0 °F i x; ;;r, <br /> Leaving DB temp. 57.7 °F <br /> « ; <br /> Leaving WB temp. 56.2 °F I i <br /> Power input(w/o blower) 8.30 kW ;f, <br /> Sound power 92 dB(A) J <br /> Refrigerant t <br /> Refrigerant type R-410A <br /> Sys1 6 lbs 8 oz . <br /> Sys2 6 lbs 8 oz <br /> Gas Heating Performance <br /> Entering DB temp. 60 °F 10 Ton <br /> Heating output capacity(Max) 144 MBH • York Predator units are manufactured at an ISO 9001 registered facility <br /> andHeaair 480 MFM <br /> Heating input capacity(Max) 180 MBHeach rooftop is completely computer-run tested prior to shipment. <br /> Leaving DB temp. 93.3 °F Unit Features <br /> Air temp.rise 33.3 °F <br /> SSE 80.0 % • Two Stage Cooling <br /> Stages 2 • 180 MBH Input Aluminized Steel,Two Stage Gas Heat <br /> Supply Air Blower Performance • Full perimeter base rails with built in rigging capabilities <br /> Supply air 4000 CFM • Unit Cabinet Constructed of Powder Painted Steel,Certified At 1000 Hours <br /> Ext.static pressure 0.6 IWG Salt Spray Test(ASTM B-117 Standards) <br /> Addl.Unit Losses(Options/Accessories) 0.56 IWG • Reciprocating Compressor <br /> Blower speed 1013 RPM • Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods(Bottom or <br /> Max BHP of Motor(including service factor) 3.45 HP Horizontal End Return Only)with Economizer Fault Detection&Diagnostic <br /> Duct location Side (Meets ASHRAE 90.1-2013,IECC 2015,California Title 24,AMCA 511). <br /> Motor rating 3.00 HP • Slide-out Blower/3 HP Belt Drive Motor Assembly <br /> Actual putred BHP 2.30 k • Unit Shi s with 2"Throwawa Filters <br /> Powerwer inrput 2.30 kW p Y <br /> Elevation 30 ft. • Solid Core Liquid Line Filter Driers <br /> Drive type BELT _ • Replacement Filters:4-(24"x 20").Unit accepts 2"or 4"wide filters. <br /> Electrical Data • Short Circuit Current:5kA RMS Symmetrical <br /> Power supply 208-3-60 • Through-the-Curb and Through-the-Base Utility Connections <br /> Unit min circuit ampacity 48.5 Amps • Single Point Power Connection <br /> Unit max over-current protection 60 Amps • Supply Air Smoke Detector <br /> Dimensions&Weight • Phase Monitor <br /> Hgt 51 in. Len 89 in. Wth 59 in. • Micro-Channel"all-aluminum"condenser coil,Copper tube/aluminum fin <br /> Weight with factory installed options 1255 lbs. evaporator coil <br /> Clearances • Composite Drain Pan-Front Connection <br /> Right 12 in. Front 36 in. Back 36 in. • Hinged Access Panels <br /> `Top 72 in. Bottom 0 in. Left 36 in. l BAS Controller <br /> Note: Please refer to the tech guide for listed maximum static pressures •• IntelliSpeed control of the VFD based on stages of cooling.Provides Single <br /> Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10. <br /> M AMERICAN/ e).L__4� 1 • Simplicity SE Controller including Discharge Air,Return Air,and Outdoor Air <br /> ry��'CERTIFIED,, auauTva .�w,A °. ° totiamoml llulr� U9 ---� Temperature Sensors <br /> Standard Unit Controller: Simplicity Control Board <br /> • Safety Monitoring-Monitors the High and Low-Pressure Switches,the <br /> Freezestats,the Gas Valve,if Applicable,and the Temperature Limit Switch <br /> on Gas and Electric Heat Units.The Unit Control Board will Alarm on Ignition <br /> Failures,Safety Lockouts and Repeated Limit Switch Trips. <br /> Warranty <br /> • One(1)Year Limited Warranty on the Complete Unit <br /> • Five(5)Year Warranty-Compressors and Electric Heater Elements <br /> • Ten(10)Year Limited Warranty-Aluminized Steel Heat Exchanger <br /> (..--'......\ <br /> Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 08/04/2017 ‘,...,. /4.)11' <br />
The URL can be used to link to this page
Your browser does not support the video tag.