Laserfiche WebLink
GENERAL Y NO <br /> 0 <br /> Bathroom doors are easily and quickly openable from the outside when locked 1110 <br /> Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. Q <br /> Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate ..,/ <br /> steeping area in the immediate vicinity of sleeping rooms(R314). 10 0 <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all 0' Q <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements. Q Q <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 12er0 <br /> Pocket doors shall have graspable hardware available when in the closed or open position. 0 <br /> 0313-8 WIMPS YES NO <br /> Inside Ramp N/Aidr <br /> D 0 <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) D 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes <br /> directions. 0 0 <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. Q 0 <br /> Outside Ramp N/A Q YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).{Exception R311.8.1 Not allowed in AFH) 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes {�a/ Q <br /> directions. <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. Er 0 <br /> �,r <br /> Guards below are depicted vertically as an example only.AR Ramps must have Guards 13 0 <br /> Handrail both sides <br /> Less than 4 34"-38" <br /> Guard <br /> 36"min <br /> --_ - 3`x 3'min <br /> -- landing <br /> 3'x 3'minlanding <br /> + 3' One unit vertical in twelve units horizontal I—3'--,.1 <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> 8331.2 Means of Egress. . . y NO <br /> R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). ef0 <br /> R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry O 0 <br /> without use of key,tool or special knowledge. Required exit door shall have no additional locking devices. <br /> 8311.7 Stas( N/A D_I: YES NO <br /> R311.7.4.1 Riser Height Max riser height shall be 7% inches(8 inches in structures built prior to July 1,2004) <br /> Er' 8 <br /> 8311.7. .2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built prior to July 1,2004) <br /> <R325lJandrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple e <br /> risers.Handrails shall be installed in accordance with R311.7.7.1—R311.7.7.4 <br /> Effective:2013 July 01 <br /> Updated:2013 June <br /> �3 <br />