Laserfiche WebLink
. NOTES: <br /> ). 12"TO 24" <br /> A -,� t' i 1. PROVIDE NO-OX GREASE AT CONTACT SURFACE BETWEEN LUG AND GROUND BAR <br /> ,`r. �7 qOn <br /> • �Lr WEATHERPROOFING 2. CONTRACTOR WLL VERIFY BUSS BAR GROUNDING TO THE TOWER OR RING. �`' �q- .f' <br /> tY I- RRU TO ANTENNAS KR(TYP.) ANTENNA CABLE N� :AS' ,7�y <br /> '`I 3. GROUND BARS AT BOTTOM OF WATERTANK SHALL USE EXOTHERMIC !,�COQ ,1//, <br /> TYPE HS TYPE 2-YA-2 TYPE XA TYP Yi.k TYPE - �■��■ \ CONNECTION. w C. <br /> \ ANTENNA,MOUNT,COVP,AND FRBG <br /> ® g GROUNDING KIT:#6 AWG STRANDED Cu ERE % <br /> WITH GREEN,600V,THWN INSULATION OR / <br /> ■ �:�8 �� WEATHERPROOFING KIT BLACK '� <br /> '1. 4�. ` �y fti w� JUMPER ■-.' -� ■ KIT(SEE NOTE 3) V ,� TWO-HOLE LUG,BOLTED `1 1 <br /> 4 ■ #6 AWG STRANDED Cu WIRE WITH TO GROUND BAR USING 40 �^1 <br /> TYPE TA TYPE VN TYPE NC TYPE SS TYPE Y �1 r-- GREEN,600V,THWN INSULATION OR - l 3/8"-16 x 1 1/4"STAINLESS 15 4).6' <br /> �.E_ui■jUI ,, �� BLACK(GROUNDED TO GROUND BAR) STEEL HEX UNIT BOLTS C} GiS 01- <br /> Ns <br /> �""'� /''� ANTENNA CABLE Q AND HARDWARE. SS'(TYP•) CABLE GROUND KIT TO ANTENNA CABLE CONNECTION NAL I$.14,17 <br /> J _� =` WEATHERPROOFING ) 0 Q Q Q 0 O O O 0' O ---EXISTING 4"xl2"xt/4" <br /> yy �R.� KIT(TYP.) THK.,TINNED <br /> IT lsnvwunoN OF LAW FOR ANY PERSON,UNLESS DIET <br /> ri‘ <br /> 4� ��_� �`��;, ■ #B AWO STRANDED COPPER GROUND O OO O 0 0 O O OO O GROUND BAR ON ARB ACTING UNDER THE DIRECTION OFAucExsEo <br /> `-- O O <br /> PROFESSIONAL ENGINEER.TOALTER THIS DOCUMENT. <br /> .14 <br /> TO PVP BOX OR TMA IIIWO WIRE(GROUNDED TO GROUND BAR) O O O O WALL,FLOOR OR ON <br /> (WHEN REQUIRED) (� II I, (SEE NOTE 1&2) N07E9: O 0 O O O O O O ANTENNA TOWER <br /> TYPE VV TYPE VS TYPE VB TYPE PT TYPE OR u u T <br /> (B)ANTENNA GROUND NEW#2 MO SOLID TINNED BARE CU 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS j, ••Mobile■ <br /> NOTE: BAR II WIRE TO TOWER GROUND BAR DIRECT GROUND WIRE DOWN 70 GROUND BAR. `,-� <br /> OR MAIN GROUND BAR - EXOTHERMIC WELD <br /> ERICO EXOTHERMIC"MOLD TYPES"SHOWN HERE ARE EXAMPLES.CONSULT WITH PROJECT 2. GROUNDING KIT SHALL BE WITH TWO-HOLE LUG. <br /> MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. .. 19807 NORTH CREEK PARKWAY NORTH <br /> 3. WEATHERPROOFING SHALL INCORPORATE PPC WEATHERPROOFING NEW(2)#2 AWG SOLID TINNED BOTHELL,WA 98011 <br /> TAPE KIT,COLD SHRINK SHALL NOT BE USED. BARE Cu WIRE TO WATERTANK <br /> GROUND BAR OR MAIN <br /> R <br /> SCALE GROUND SCALE � Associates <br /> EXOTHERMIC WELDING 1 CABLE GROUNDING N.T.S.AL2 SECTOR GROUND BAR I T®chnolo <br /> N.T.S. PNWMARKETOFFICE <br /> NOTES: 650 SOUTH ORCAS STREET,STE.R-103 <br /> SEATTLE,WA 98108 <br /> NEW#6 AWG STRANDED Cu NEW EQUIPMENT SHELTER&ALL ITS EQUIPMENT 1. PROVIDE NO-OX GREASE AT CONTACT <br /> WIRES TO NEW EQUIPMENT WITH GREEN,KIT:#6 AWG STRANDED Cu WIRE SURFACE BETWEEN LUG AND GROUND BAR <br /> WIRE SIZE BURNDY LUG BOLT SIZE pp <br /> WITH 600V,THWN INSULATION OR BLACK 2. CONTRACTOR WILL VERIFY BUSS BAR TBVhnolOgy Associates <br /> GROUNDING TO THE TOWER OR RING. #6 AWG GREEN INSULATED YA9C-2TC38 3/8"-18 NC S 2 BOLT <br /> 3. GROUND BARS AT BOTTOM OF WATER TANKHEAT SHRINK BURNDY GROUND LUG <br /> #2 AWG SOLID TINNED YA3C-2TC38 3/6" - ARCHITECTURE&ENGINEERING <br /> SHALL USE EXOTHERMIC <br /> (CLEAR HEAT SHRINK INDOOR 8 (SEE TABLE FOR SIZE <br /> r- -1 J, - CONNECTION. #2 AWG STRANDED YA2C-2TC36 3B"-16 NC 82 BOLT BLACK HEAT SHRINK OUTDOOR) 1. AND MODEL) 3111 CAMINO DEL RIO NORTH,STE.400 <br /> BURNDY GROUND LUG SAN DIEGO,CA 92108 <br /> EE TABLE,...� l.�/-\, #2N AWG STRANDED YAZE-2TC38 3B"-18 NCS 2 BOLT AND MODEL)OR 812E I, 9BBARE WIRE <br /> OTH ENDS BE NO-OX A7 <br /> / 1 2 11/11/2018 ISSUED FOR 10046 CD MGM <br /> NEW MAIN GROUND BAR #4)0 AWG STRANDED YA26.2N 12"'16 NC 8 2 BOLT NUT(TYP.) ' <br /> 0 00000000 000000000000 LOCK WASHERll <br /> •. / OG1U2017 REMOVED LANDSCAPE PIAN SPL <br /> OO 00000000 O O O V © G O O 0000 OO NOTES: (TMP.) i. .. © 0027f2013 ADDED LANDSCAPE PIAN MGM <br /> FLAT WASHER .._ . A 03/112013 ISSUED FOR CITY REVISIONS MGM <br /> O �r O O O Q O O O O O O O Q O O x }� 1. ALL HARDWARE BOLTS,NUTS,LOCK WASHERS (TMP.) #141111 <br /> ,#-��' <br /> V tJ lJ SHALL BE STAINLESS STEEL. ALL HARDWARE o Os;temis ISSUED FOR 100%CDREVIEW MGM <br /> ARE TO BE AS FOLLOWS:BOLT,FLAT WASHER, s 07ni/207T RELOCATE LEASE AREA SPL <br /> 1111111111. <br /> 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 GROUND BAR,GROUND LUG,FLAT WASHER, GROUNDING <br /> LOCK WASHER AND NUT. °" "" CONDUCTOR <br /> �` GROUND BAR REV DATE DESCRIPTION BY <br /> L J ��V11/\ EXOTHERMIC WELD 2. COPPER SHIELD,ANTIOX CR NO-0X OR FLAT WASHER BOLT(TYP.) <br /> TWO-HOLE LUG,BOLTED TO 1.-. EQUIVALENT SHALL BE PLACE WHERE ALL (TYP) <br /> ...-- <br /> 1 <br /> DISSIMILAR METALS CONNECT. SE01}♦t /�/L <br /> I_ GROUND BAR USING Tx 1 L"' 8(�5A <br /> 1/4"STAINLESS STEEL HEX UNIT �_NE1N 2 3. ALL LUGS ARE TO BE INSTALLED PER <br /> 1 BOLTS AND HARDWARE. #2 AWO SOLID TINNED BARE Cu WIRE TO MANUFACTURER'S SPECIFICATIONS. <br /> �BNEW GROUND RING CASCADE HIGH <br /> 4. ALL LUGS MUST HAVE INSPECTION WINDOWS. <br /> SCHOOL N. <br /> MAIN GROUND BAR SCALE WATER TANK <br /> y� N.T.S. 4 MECHANICAL LUG CONNECTION N.T.S. 5 7410 OLYMPIC DRIVE <br /> S <br /> #2AWOGREENINSULATEDCOPpER EVERETT,WA 98203 <br /> NOTES: 1B MIN. <br /> STRANDED WIRE(MAIN)(HALO) WATERTANK <br /> 1. HALO GROUND SHALL BE#2 AWG STRANDED GREEN COPPER WIRE. 1/4"MAX. WIRE RETAINER HARNESS <br /> PANDUIT OR EQUAL <br /> 6"0x 24"DEEP INSPECTION SLEEVE, 2, VERTICAL DROPS SHALL BE#2 AWG STRANDED GREEN COPPER WIRE. pp''�� (P/T#RER.S-SB-X) <br /> #2 SOLID TINNED BARE S <br /> COPPER WIRE EXOTHERMIC = PVC OR 901E PIPE WITH CAP OR • <br /> WELDED TO THE I <br /> EQUIVALENT. 3. ALL BENDS SHALL MAINTAIN A MINIMUM 8"BEND RADIUS. ..=._..:__________ <br /> ,�- TOP OF GRADE APPROPRIATE ITEMS F,ISH,+GRADE 4, APPLY ANTI-OOXIDATION COMPOUND TO ALL CONNECTIONS. <br /> .':/�� / Tye "v-P/ .r,..,,,-,,,,,,,-,,,-2,,,,,,,,;, �.��.; ^.,::.,,:.,,,,:.:.,,..,.,-._ ,.;.. COMPRESSION <br /> SI :EXOTHERMIC ,j i„, ,•>,:>>>,,Ate ��4-A7--,,,)›.- <br /> ( ,�'`�'` ��J �' 6. ALL GROUNDING WIRES FOR HVAC GRILLS,BOXES,DOORS.CABLE TRAYS,ETC.,SHALL BE#6 AWO GREEN CONNECTOR 'I <br /> F r- \,�`.\ G1 I.N�\ \a,\.yyf `- /��,.//��f\��\/\1 ,\�j,,, ,,\/.</ ,/. <br /> ,\/.</�,�r\�`�7.'/ 1 STRANDED COPPER WIRE AND A 2-HOLE LUG. (SPLIT-BOLT) <br /> g 1&144 `&���`'((��� `f\�. \\//\/' ../% \\�\//\.%�//1'//\\/�\ 8. •BARE COPPER CONDUCTORS SHALL NOT BE IN CONTACT WITH ANY DISSIMILAR MATERIAL PLACE ON �• <br /> v p EXOTHERMIC \`'''',,,(c/\�;\�j\% ���\‘/‘A\//;1\`�%'•yl' STANDOFFS IF NECESSARY TO ALLOW FOR PROPER INSTALLATION. <br /> XOTHERMIC TO EX.. Fi 73,,,,V...„\ <br /> \�\%���j` „, <br /> /\\\�'"`\7"WIDE SLOT FOR 7. ALL GROUNDING CONDUCTORS SHALL BE KEPT AS SHORT AS POSSIBLE.THE SHORTEST PRACTICAL ROUTE <br /> '� GROUND RING y /\�\/ / /�\ SHALL BE CHOSEN WITH THE LEAST AMOUNT OF BENDS AND SPLICES,USE THIS RULE AT ALL TIMES,EVEN IF <br /> M ( \\ \ S \\ GROUND WIRE,EXTEND ELEVATION PLAN CONFLICTS.PLANE ARE SOMETIMES UNCLEAR DUE TO SCALE. <br /> IX Iv- 1�1 I.I ■ ��� f•� 2'ABOVE GROUND WIRE JURISDICTION APPROVAL STAMP <br /> / `\\j �' r\\` \ 8. ALL CONNECTIONS TO GROUND BARS SHALL SE WITH A 2-HOLE LUG,UNO. DEPARTMENT <br /> FOR BUILDING TPOR LAND 4 CONSE <br /> STRUCTION <br /> ffi #2 SOLID TINNED BARE '' y�' /, CADWELD CONNECTION <br /> COPPER GROUND RING �' ��9 (SVP-GT) #2AWG GREEN INSULATED <br /> 30"BELOW GRADE / B. ALL SOLID WIRE SHALL USE A 2-HOLE LONG-BARREL LUG. COPPER STRANDED WIRE SHEET TITLE <br /> (TAP) <br /> _ _. - - 10. WHEN GROUNDING MORE THAN ONE PIECE OF EQUIPMENT,DO NOT USE THE EQUIPMENT AS A GROUNDING GROUNDING <br /> 5B"DIA.x 1d LONG 314"CRUSHED GRAVEL OR EQUAL FILL CONDUCTOR.DOUBLE STACKING OF LUGS IS NOT ALLOWED TO 8E USED. <br /> #2 AWG SOLID TINNED TEST WELL TO WITHIN 2'OF TOP OF DETAILS <br /> COPPER CLAD FROM TMO EQUIPMENT <br /> GROUND ROD COPPER WIRE GROUND LOOP 11. REMOVE ALL PAINT BENEATH THE SURFACE OF GROUND LUGS.INSTALL PANDUIT CLIP AN"Y"DROP AT CABLE <br /> EXOTHERMIC (EXTERIOR GROUND RING) TRAY TO AVOID CONTACT WITH CABLE TRAY. <br /> CONNECTION <br /> 20'-0"MAX COPPER CLAD GROUND 12. ALL GROUND WIRES CONNECTING TO THE HALO SHALL CONNECT IN THE SHORTEST DIRECTION TO THE MAIN <br /> 10'-0"MIN. ROD 5/8"0 X 10'-0"LONG GROUND BAR. SHEET NUMBER <br /> W 13. INSTALL GROUND BAR UNDER INSTALLED COAX.ALL WIRING AT GROUND BAR IS TYPICAL FOR ALL LOCATIONS. <br /> gG-2 <br /> = SGROUND ROD N.T.S.CE S6 TEST WELL N.T.S.CE 7 HALO GROUNDING SCALE. 8 <br /> . (fl"/4/173.\) <br /> i <br />