|
LEGEND
<br /> POINT OF CONNECTION
<br /> 11 11� � x���(�� PHASE 2 DEMO
<br /> 11 .5 12 12.5 � 13
<br /> �
<br /> � E � � �
<br /> �
<br /> � � � � ' ! FOR CONTtNUATION SEE TOOLING
<br /> I ( � ,
<br /> I , , i I � FOR CONTIN�UATION � 0 DRAWING FME 141W0000-1, SH M16 �
<br /> � I I � SEE TOOLING�DRAWING 1
<br /> � FME 141W0000-1, SH M16 ��
<br /> � i � I � � � � 8 FIRE RISER(REF)
<br /> I � � 2I' SAN FROM TOOLWG 2 A�P �� R �REF> GEN ERAL NOTES
<br /> I ( I � I I 4° SAN DOWN � I I 1/2 CW DOWN FOR CONTINUATION SEE „ � SEE TOOLING DRAWING FME 146W0002,SH M16 FOR HYDRAULIC TUBING
<br /> , � ' 2°VUP
<br /> O � I I � I EWC-1 TOOLING DRAWWG 1 1/2 SAN INSTALLATION AND MATERIAL REQUIREMENTS.
<br /> � I � � I � � ( FME 141 WOOOO-1, SH M19 3 3°V UP 2. COLD WATER(CV1�PIPING:TYPE L COPPER WITH COPPER SOCKET JOINT
<br /> I � ( ; -- 1-1 �°= - "�A D WN FITTINGS. INSULATE WITH 1"FIBERGLASS WITH FACTORY-APPLIED ALL-
<br /> I ---`� i � I ,f.., -- _ 1° CW UP , � � -__ - , 1/2° CW ;�, 1 1/4" CW DN SERVICEJACKET.PROVIDE FACTORY-MOLDED PVC COVERS FORVALVES
<br /> � � I � � f � � _ � � _ �� �_ �� -- - - - � AND FITTWGS.
<br /> � � _ � _ _ I _ � �� I — — �
<br /> t�� — � � — — — — — — — �r_: 2" BOP EL '� " i � , � ��_ TO SSEW nA
<br /> �"- I , I ��`_'t���r I — , � — — —� — — — �— — - — I I� , � �r` -r _ �2 BOP EL 116 6 — � _ - - c � � '� �� �_ ��
<br /> � � ,� � — � — i - i; _ �� 1_. -+,, _, i i � � _ � � CW 'V' 3. DRAIN(D)PIPING:ASTM A53 BLACK STEEI.SCH 40 WITH 150#MALLEABLE
<br /> � � + I - i i - - ( - ��1 '� '— — — � IRON I T NGS.
<br /> - �- - - - - ' � I �_ -- - - - - ___ -_ -- - -- - -- - - - --- - - - - - - - - - - - -- - --- -- - - - -- -- - - - - - -- - - - -- - - - � T _ F T I
<br /> I � � �- - - � - -- - --- -� --- -- - -- -- - -�- n�I � L � � I � 4. OR SHALL PERFORM"POTABLE WATER SYSTEM TESTING"AS
<br /> i �- � � _ _ _ _ _
<br /> — - — — -- — -- --- — + � - - - - - - + � - - - - - - - - I
<br /> THE CONTRACT
<br /> EWF-1 - - - - - DESCRIBED IN THE BOEING ENGINEERING DOCUMENT DI-0565.0567 DATED
<br /> 4" BOP EL 116'-6" 2"V UP,4" SAN DOWN 3"V DOWN SSEW-1 FEBRUARY 29,2008.
<br /> � 1/2° CW DN 4" BOP EL 116�-6° 6�� HUB DRAIN ( 5. SUPPORT ALL PIPING PER UNIFORM PLUMBING CODE IN AREAS NOT
<br /> � � TO EWF-1 6" HUB DRAIN 4"�CW DN WITH T.P. � SPECIFIED.
<br /> 1 1/2" SAN DN
<br /> � �-� 2��W REMOVAL NOTES
<br /> I I I I �---_—I � � 1 REMQVE SANITARY LINE FROM TOOL TO HUB DRAIN.HUB DRAW TO
<br /> 1 1/2" PSAN DN 2 � REMAIN.
<br /> P3-2
<br /> � � � ---- --- - ------ _-_ ---� 1-1/2��V UP � REMOVE HYDRAULIC LINES FROM TOOL TO SOURCE. COORDIANTE WITH
<br /> � I BOEING EHS PRIOR TO DEMOLITION.
<br /> � -- --- -- --- - --- I / -- �- --- - -T - - -- - - - - - -- -- - - -- -- -- - - - - �_- - _- � _- - -y---� ��., - - - --- - -- i -- - - -- -- - - - -- -- ---- -- - - - -�
<br /> _ --�
<br /> - - - - -- - --- - --- - -- I � , - - - - -- - -- - - - - - -- -- - - - � -
<br /> - --- -- - -- -- - - _ - .
<br /> -- - - -
<br /> I / / I r � � i /'l �� �.�, ': I I � I � � � � � �� � � ' �I2°C�lil TO SINK 3 ,� REMOVE COLQ WATER LINE FROM TOOL BACK T01 1/4"SOURCE AND CAP.
<br /> I I I __I- I I � I 2 W UP TO FD-1 WITH
<br /> r � � I � I � I I I AND COFFEE
<br /> � I { I I � � �,� __�r ' � i � � i i I I TRAP PRIMER - -o i i MAKER
<br /> �
<br /> � I � � I ( � � , �--i'�- � � � I ' � � � � I 1/2"HW I I (
<br /> , L � �
<br /> i � i �_ I�� , , , I , -- � �
<br /> I ' � � '— i�lr—il '� ' � � � ' , � I— -
<br /> �--
<br /> i � � � ! � �- —, ��� I� � , � � �.� , I I
<br /> I , ��,'� � �,�---� ,������ �� � � � � � � � 3l4" HYS � �--� 3l4", � �
<br /> � I I � I I I �� ---'`� �
<br /> --�,��-- , j � I � � I � � � � 3/4" HYR � �� � I
<br /> I i � ��; f -- ,j „ � � � � � ; i ( F— � 4 I �Q� _
<br /> I � � ' I I — I�i -- ' 3 V UP & DN I � I � l i I I „ I,— _ ( � �
<br /> I � � L I 1 1/2 PSAN I � I U DERSLAB
<br /> � — � � � � � � � - - � i ��� T�-Hl1&DRAIN==� � I � � ��� � � � � I 3l4 HWC UP 3�� � �� I --
<br /> ,��� -_ T � �-- � --��- � „ � � , � �- ---��� � � � �� REFER�ENCE DRAWI NGS
<br /> �
<br /> ��� — — — � — —���T — — — — — —r- l� � ����. —_ —_—' �-6 HUB DRAIN _ I I _ I I j, fl� _ — � — — — — _ �����,��— _
<br /> �i� �,�i� ^'
<br /> ��j � _ ��--- -- — -- — — - __- --- ---� �'- � WITH T.P. ' � �� � ,. �/ ��
<br /> _� ,�- � � , (E)4 SAN UP& �,� _,
<br /> � FOR CONTINUATION SEE 6" DN W/ WCO ���
<br /> I I � � TOOLING DRAWING �
<br /> FME 146W0002, SH M17
<br /> I
<br /> I I � � �
<br /> 0
<br /> �� ��, BLDG 40-034
<br /> 12 13 14 15 16 11
<br /> K � �� --�K
<br /> �' 10 11 �'
<br /> � - - -� - �
<br /> 13 � 14 �
<br /> L3 � � � � I L3
<br /> BLDG I I
<br /> 40-025 16 � 17 �
<br /> �.� — -. —� — ��
<br /> 19 � 20 �
<br /> M � M
<br /> 2 23
<br /> N N
<br /> ii fi' 12 13 14 15 i6 17
<br /> BLDG 40-036
<br /> BUILDING 40-035 KEY PLAN n'
<br /> NTS 'v
<br /> 0 4' 8' 16' 24'
<br /> 1/8"=1'-0,�
<br /> PARTIAL FIRST FLOOR COMPRESSED AIR PLAN
<br /> P Copyright o 2016
<br /> FSi consull_ing enginee�� .
<br /> L : 1 8"=1'-0' tiwvw.br h.com
<br /> S e a t't I e, ��J a s h i n g't o n Architects, En�neers, Constructors
<br /> 19020 33rd Ave W,Suite 530 State of Washington
<br /> Certificate of Authorization
<br /> gn Lynnwood,Washington,98036 Architecture No.603235512
<br /> �U�u t�U r�� CX. S�'rU�C� 425-921-3500 Engineering No.3137 �
<br /> n
<br /> ORAWN DATE SUBTITIE CURRENT REVISION SYMBOL DATE �'
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE �
<br /> o�,�,F ACCEPTABILITY DGD 07127116 REMOVAL PARTIAL FIRST FLOOR �
<br /> �� 16321 0 07/27/16 �
<br /> 0 Release 8-IFC Wing Body Join-(WBS16321)(25-35) FSi REG 0712716 /��. �� o� 4va�y,���p�G THis DESIGN AND/oR KMC KED 07127116 COMPRESSED AIR PLAN
<br /> � �, T ; SPECIFICATION IS APPROVED sHEET �
<br /> BOE,��� � � oL - ENGINEER TITLE FACTORY TRANSFORMATION 777x Wing Bady Join �
<br /> � APPROVED BY DEPT. DATE KRL 07/27116 �
<br /> �HE�KEo 1 M 111 -2 2 R — �
<br /> � ��°� 3�° �� BUILDIN� 40-035 r
<br /> o�, cisrE�E �� APPROVED
<br /> Fss�oraa� ENG JOBNO. WO ,15/2899-800 COMPNO. c
<br /> �,,,,� APPROVED MECHANICAL MASTER COL 11-13/M-N EVERETT, WA °WGNO. 40-035-1M111-22R-800
<br /> SIL',1`i0 � �
<br />
|