SYSTEM DESIGNATIONS LIGHTING ABBREVIATIONS
<br /> � DISCONNECT SWITCH, FUSED, 30=SWITCH RATING, A FIXTURE TYPE DESIGNATION. SEE FIXTURE SCHEDULE, A/C AIR CONDITIONING �N INCH
<br /> HASH MARKS INDICATE THE QUANTITY OF CONDUCTORS 30/20 20=FUSE RATING 2_34 SHT. X. QUANTITY AND RATING OF LAMPS AC ALTERNATING CURRENT (NFO INFORMATION
<br /> (#12 WIRE UNLESS OTHERWISE NOTED). IF UNMARKED (A=TYPE, 2=QUANTITY, 34=LAMP RATING) A.F.F. ABOVE FINISHED FLOOR �B JUNCTION BOX GENERAL I�OTES
<br /> INSTALL 2#12 IN 1/2 CONDUIT �, DISCONNECT SWITCH, NON-FUSED, 30A AWG AMERICAN WIRE GAUGE KW KILOWATT
<br /> PHASE CONDUCTORS UNLESS NOTED OTHERWISE � LAY-IN FLUORESCENT FIXTURE, 4 LAMP, TYPE AS NOTED AMP AMPERE KWH KILOWATT HOUR 1. ALL DISTRIBUTION PANELS 480V, 480Y/277V, 208Y/120V
<br /> NEUTRAL CONDUCTOR IF REQUIRED APPROX APPROXIMATE KV KILOVOLT 600AMP BUS AND LARGER SHALL BE FLOOR STANDING
<br /> � � m MOTOR CONTROLLER LG LONG 90" HIGH. PROVIDE 3 1/2" THICK CONCRETE PAD, ANCHOR
<br /> GROUND CONDUCTOR(IF REQUIRED) � LAY-IN FLUORESCENT FIXTURE, 3 LAMP, TYPE AS NOTED ARCH ARCHITECT OR ARCHITECTURAL LGTH LENGTH EQUIPMENT TO FLOOR W 4 1/2"BOLTS
<br /> � CAPACITOR AUTO AUTOMATIC LT LIGHT /
<br /> 3V34-1 D6A 7,9,11 AUX AUXILIARY 2. 4"� TO 6"� HOLES MINIMUM SPACE REQ. I�1 BETWEEN
<br /> 3/4 C,3#8 / PANEL HOME RUN � LAY-IN FLOURESCENT FIXTURE, 2 LAMP, TYPE AS NOTED BOT BOTTOM LGT LIGHTING HOLES 6".
<br /> PANEL/CIRCUIT � TRANSFER SWITCH, SIZE AND TYPE AS NOTED BLDG BUILDING MAG MAGNETIC 3. 1 "�, 2"� & 3"� HOLES MINIMUM SPACE REQ. IN BETWEEN �
<br /> CONDUIT/CONDUCTORS MAINT MAWTENANCE
<br /> 0 TRANSFORMER, SIZE AND TYPE AS NOTED CAB CABINET
<br /> � FLOURESCENT FIXTURE ON EMERGENCY SYSTEM, TYPE AS NOTED
<br /> CAT CATALOG MFG MANUFACTURER HOLES 3".
<br /> CONDUIT RUN EXPOSED � CB CIRCUIT BREAKER
<br /> MOTOR, 120V,1?, SIZE AS NOTED E MECH MECHA CAL 4. CABLE TIES USED FOR BUILDING TELEPHONE OR FIBER
<br /> CONDUIT RUN CONCEALED IN WALLS, ABOVE CEILING, IN FLOOR � CLG CEILING OPTIC CABLES IN PLENUM SPACES SHALL BE TYTON
<br /> MEZZ MEZZANINE
<br /> SLAB OR UNDERGROUND � MOTOR, 208V, 3?, SIZE AS NOTED L� SUSPENDED OR SURFACE MOUNTED FLOURESCENT CHWR CHNLLED WATER RETURN MIN MINIMUM �T50R-HAL OR �T50L-HAL OR ENGINEER APPROVED
<br /> (-Zr-I FIXTURE, 1 LAMP, TYPE AS NOTED CHWS CHILLED WATER SUPPLY MISC MISCELLANEOUS EQUAL
<br /> T TELEPHONE, 3/4" MINIMUM CONDUIT ONLY, UNLESS SIZED OTHERWISE o MOTOR, 460V, 3?, SIZE AS NOTED MTD MOUNTED
<br /> CKT CIRCUIT 5. CONTRACTOR SHALL LOOP THE FIBER OPTIC CABLE
<br /> FIBER OPTIC, / , � JUNCTION BOX FIELD SIZED OR AS NOTED � SUSPENDED OR SURFACE MOUNTED FLOURESCENT COAX COAXIAL MTG MOUNTING
<br /> FO 3 4"C. MINIMUM WITH CABLE AS (NDICATED. UNLESS SIZED ' FIXTURE, 2 LAMP, TYPE AS NOTED COL COLUMN NEC NATIONAL ELECTRIC CODE (APPROX. 2FT. DIA.) INSIDE THE FURNITURE
<br /> OTHERWISE. NO CONDULET FfTTINGS IN FIBER OPTIC RUNS ALLOWED � GROUNDING PIGTAIL C CONDUIT NC NORMALLY CLOSED PARTITIONS PRIOR TO TERMINATING.
<br /> E EMERGENCY CIRCUIT 0 PULLBOX, FIELD SIZED OR AS NOTED � C.O. CONDUIT ONLY NIC NOT IN CONTRACT 6. CONTRACTOR SHALL PROVIDE PHYSICAL PROTECTION
<br /> FLUORESCENT FIXTURE WITH BRANCH CIRCUIT CONNECTION CONT CONTINUE NO NORMALLY OPEN FOR THE TELEPHONE ANQ FIBER OPTIC CABLES WHERE
<br /> FA FIRE ALARM CIRCUIT �B JUNCTION BOX, SPECIAL. FIELD SIZED OR AS NOTED � POINT, 3 LAMP, TYPE AS NOTED CU COPPER NTS NOT TO SCALE THEY ENTER THE POWER POLES.
<br /> No. OR NUMBER
<br /> PA PAGING CONDUIT WITH WIRE AS NOTED � GENERATOR, ALTERNATING CURRENT � CT CURRENT TRANSFORMER OC ON CENTER
<br /> (VOLTAGE, KW, FREQUENCY AS NOTED) DC DIRECT CURRENT 7. ROBERTSON "EASY ACCESS-DELUXE" ACTIVATION KIT
<br /> G COPPER GROUND WIRE, SIZE AS NOTED O GROUND ROD, SIZE AS SPECIFIED OR NOTED FLUORESCENT FIXTURE WITH BRANCH CIRCUIT CONNECTION DED DEDICATED CIRCUIT OD OUTSIDE DIAMETER COMPLETE WITH COVER, FLANGE RING, DUPLEX MOUNTING
<br /> D DATA CONDUIT WITH CABLE O THERMOSTAT � POINT, 4 LAMP, TYPE AS NOTED DEG DEGREE �NL PANEL COVERS (FOR RECEPTACLES INDICATED IN LEGEND)
<br /> DET DETAIL PERCENT MOUNTING STRAPS, ACTIVATION RING ASSEMBLY MODULAR
<br /> PERP PERPENDICULAR TELEPHONE MOUNTING BRACKET AND GROMMETS.
<br /> LV LOW VOLTAGE CONDUIT/WIRE CD CONTACTOR, TYPE AS NOTED � WALL MOUNTED OUTDOOR LIGHTING FIXTURE, TYPE AS NOTED DISC DISCONNECT ? OR PH PHASE
<br /> CONDUIT TURNED UP � CONTROL PANEL DPDT DOUBLE POLE DOUBLE THROW PVC POLYVINYL CHLORIDE g. ROBERTSON ACTIVATION KIT #4A (THREE SERVICE).
<br /> CONDUI7 TURNED DOWN j, EXPLOSION PROOF SEAL FITTING � HIGH INTENSITY DISCHARGE FIXTURE, TYPE AS NOTED DPST DOUBLE POLE SINGLE THROW PWR POWER
<br /> PF POWER FACTOR
<br /> �1,.I�J' FLEXIBLE CONDUIT, 1/2" UNLESS NOTED OTHERWISE OO RELAY M HIGH INTENSITY DISCHARGE FIXTURE, TYPE AS NOTED S�HT S�EET PE PRESSURE ELECTRIC
<br /> F- INDICTES WALL MOUNTING S � WHEN MORE THAN ONE LAMP TYPE IS USED IN AN AREA Eq Eq�H PB PUSHBUTfON
<br /> PRE-WIRED FLEXIBLE CONDUIT PROVIDED WITH LIGHT (M=METAL HALIDE LAMP, S=HIGH PRESSURE SODIUM LAMP) EL ELEVATION PR PAIR
<br /> �J F �� FIXTURE TYPES R, R-2, S AND S-2 AS LST (LABOR- SV SOLENOID VALVE ELECT ELECTRIC QTY QUANTITY
<br /> SAVING TANDEM) M EMERGENCY HIGH INTENSITY DISCHARGE FIXTURE EMT ELECTRICAL METALLIC TUBING RECP RECEPTACLE
<br /> � TELEPHONE/DATA/POWER POLE S � TYPE AS NOTED (M=METAL HALIDE EMER EMERGENCY REF REFERENCE
<br /> CABLE TRAY; SIZE AS NOTED ON THE DRAWINGS LAMP, S=HIGH PRESSURE SODIIJM LAMP) ENGR ENGINEER REQ'D REQUIRED
<br /> m PRESET FLOOR BOX WITH TELEPHONE CABLE TO SYSTEMS EQUIP EQUIPMENT REV REVISION
<br /> FURNITURE PARTITION. SEE NOTE �8. INCANDESCENT OR COMPACT FLUORESCENT FIXTURE, TYPE AS NOTED ETC ETCETERA RGS RIGID GALVANIZED STEEL
<br /> -�E-�E- CONDUIT TO BE REMOVED � EWC ELECTRIC WATER COOLER RM ROOM
<br /> � PRESET FLOOR BOX WITH DATA CABLE TO SYSTEMS EXIST EXISTING SECT SECTION
<br /> � EQUIPMENT TO BE REMOVED (EG. PANELBOARD) FURNITURE PARTITION. SEE NOTE #8. I-� INCANDESCENT OR COMPACT FLUORESCENT FIXTURE, EXTR EXTERIOR SHT SHEET
<br /> WALL MOUNTED, TYPE AS NOTED. EXP EXPLOSION PROOF SIM SIMILAR
<br /> DISTRIBUTION � PUSHBUTTON SWITCH � INCANDESCENT OR COMPACT FLOURESCENT FIXTURE ON FDR FEEDER SPDT SINGLE POLE DOUBLE THROW
<br /> EMERGENCY SYSTEM TYPE AS NOTED FIXT FIXTURE SPST SINGLE POLE SINGLE THROW
<br /> � 208Y/120V OR 480Y/277V BUSWAY SHOWN IN RECEPTACLES FLEX FLEXIBLE SPEC SPECIFICATION
<br /> 30-3P 10 FT. LENGTHS ON THE SHT.). 30- P INDICATES EXIT LIGHTING SIGN WALL MOUNTED. R FLOOR SUSP SUSP ND
<br /> 3Q AMP, 3 POLE, PLUG-IN UNIT � DUPLEX,15A,120V,1?,2P,3W, PARALLEL BLADE I-� � FL E
<br /> GROUNDED. DIRECTION OF EGRESS AS NOTED F7 FOOT SW SWITCH
<br /> � PANEL.BOARD, 480V, 3?, 3W, PANELBOARD "" FURN FURNISH SYS SYSTEM
<br /> FOUR PLEX-2 DUPLEX 15A,1?,2P,3W � EXIT LIGHTING SIGN, SUSPENDED OR CEILING GEN GENERATOR TEL TELEPHONE
<br /> � PARALLEL BLADE GROUNDED. MOUNTED. DIRECTION OF EGRESS AS NOTED GRN GREEN TRSW TRANSFER SWITCH
<br /> _ PANELBOARD, 480Y/277V, 3?, 4W, PANELBOARfl, GND GROUND T'STAT THERMOSTAT
<br /> �" SURFACE MOUNTED, FLUSH MOUNTED � O FIXTURE OUTLET SHOWN WITH FIXTURES
<br /> 30 SINGLE, WITH 30A, 480V, 3., 4 POLE, WITH � � HTR HEATER XFMR TRANSFORMER
<br /> � PANELBOARD, 208Y/120V, 3?, 4W OR 3?, 5W, PANELBOARD � BACK BOX, GROUND THRU EXTRA POLE AND SHELL. � VERTICAL LED COVE LIGHT HGT HEIGHT TYP TYPICAL
<br /> �" SURFACE MOUNTED, FLUSH MOUNTED HID HIGH INTENSITY DISCHARGE UH UNIT HEATER
<br /> 20 DUPLEX,20A,120V,1?,2P,3W, PARALLEL BLADE HZ HERTZ UG UNDERGROUND
<br /> Mcc MOTOR CONTROL CENTER � GROUNDED AUXILIARY SYSTEMS HPS HIGH PRESSURE SODIUM UON UNLESS OTHERWISE NOTED
<br /> 1? 2P 3W PARALLEL BLADE O P.A. SYSTEM ATTENU TOR WALL MOUNTED HV HIGH VOLTAGE VERT VERTICAL
<br /> 0 LIGHTING CONTROL PANEL � IG DUPLEX,15A,120V, , , , �� 10-10 WATf RATING ' HORIZ HORIZONTAL WP WEATHERPROOF
<br /> WITH ISOLATED GROUND, ORANGE � - �
<br /> HP HORSEPOWER WH WATER HEATER
<br /> o SPECIAL PANEL AS NOTED � P.A. SYSTEM SINGLE HORN W WATT
<br /> �20 FOUR PLEX-2 DUPLEX, 20A,1?,2P,3W � W/ WITH
<br /> PARALLEL BLADE GROUNDED. P.A. SYSTEM TWO(2) HORN CLUSTER W/0 WITH OUT
<br /> EQUIPMENT�DEVICES �
<br /> MECHANICAL EQUIPMENT MARK D� P.A. SYSTEM THREE(3) HORN CLUSTER
<br /> A SEE MECH. SHTS FOR TYPE � WP WEATHERPROOF� DUPLEX RECEPTACLE, 15A, 120V, 1�,
<br /> �2 DESCRIPTION AND RATING. 2P, 3W PARALLEL BLADE, GROUNDED PANEL NOMENCLATURE
<br /> � P.A. SYSTEM FOUR(4) HORN CLUSTER X 3 V35-1 U D12 A Q
<br /> (A-TYPE, 12-EQUIP NUMBER) GFI GROUND FAULT INTERRUPTER TYPE DUPLEX RECEPTACLE l
<br /> $ SINGLE POLE TOGGLE SWITCH � 15A, 120V, 1�, 2P, 3W PARALLEL BLADE, GROUNDED Q SPEAKER, RECESSED MOUNTED IN CEILING SUFFIX "D" INDICATES
<br /> DISTRIBUTION PANEL
<br /> Q SMOKE DETECTOR SUFFIX "A , B �R CC
<br /> $3 THREE-WAY TOGGLE SWITCH � EXP SINGLE, 20A, 120V, 1�, 2P, 2W, EXPLOSION PROOF IDENTIFIES A SPECIFI
<br /> FOR CLASS 1 GROUPS C 8c D � HEAT DETECTOR
<br /> SWITCH FOR LOW-VOLTAGE SWITCHING SYSTEM PANEL WHEN SEVERAL
<br /> $LV DUPLEX RECEPTACLE, 20A, 120V, 1�, 2P, 3W, PARALLEL BLADE � FIRE FIGHTERS CONTROL STATION PANELS OCCUR IN ONE
<br /> $ INDICATES THE NUMBER OF LOW VOLTAGE SWITCHES � GROUNDEQ, MOUNTED IN PRESET FLOOR BOX. SEE NOTE #7. � GONG, TYPE AS SPEGFIED LOCATION.
<br /> LV(2) AS NOTED ON SHEET. (EG. (2) INDICATES TWO PANEL LOCATION
<br /> SWITCHES AT THIS LOCATION) D� BELL, TYPE AS �SPECIFIED AT NEAREST COLUMN
<br /> $p LIGHTWG DIMMER SWITCH FOURPLEX-2 DUPLEX RECEPTACLE, 20A, 12QV, 1�, 2P, 3W, PARALLEL p LOCATION OF PANEL WHEN ABOVE
<br /> � BLADE GROUNDED, MOUNTED IN PRESET FLOOR BOX. SEE NOTE �7, � MAGNETIC DOOR RELEASE FIRST FLOOR: _
<br /> �3-D THREE-WAY LIGHTING DIMMER SWITCH � ANUNCIATOR TN-TUNNEL, U-2ND FLOOR, V-3RD FLOOR
<br /> W=4TH FLOOR, X=STH FLOOR
<br /> •• PUSHBUTfON STATION ��� DUPLEX RE�EPTACLE, 20A, 120V, 1�, 2P, 3W, PARALLEL BLADE 8 FIRE ALARM PANEL T=TRUSS LEVEL
<br /> WITH ISOLATED GROUND, ORANGE. MOUNTED IN PRESET � TELEPHONE CABINET
<br /> � MANUAL MOTOR STARTER FLOOR BOX. SEE NOTE #7. SOURCE OF POWER - VAULT N0.
<br /> �J DATA CABINET VOLTAGE � 4 PANEL - 480V, 3�, 3 WIRE
<br /> � MAGNETIC MOTOR STARTER �(2) TWO FOURPLEX RECEPTACLES, 20A, 120V, 1�, 2P, 3W, PARALLEL BLADE � 3 PANEL - 480Y/277V, 3�, 4 WIRE
<br /> GROUNDED, MOUNTED IN PRESET F1.00R BOX. SEE NOTE #7. Ir TELEPHONE OUTLET, WALL MOUNTED 12" AFF OR AS NOTED � 2 PANEL - 208Y/120V, 3�, 4 WIRE OR 3�, 5 WIRE
<br /> �, COMBINATION STARTER, CIRCUIT BREAKER TYPE, �Q DATA OUTLET, WALL MOUNTED 12" AFF OR AS NOTED "X" INDICATES EMERGENCY PANEL
<br /> 30A UNLESS NOTED OTHERWISE "I" INDICATES ISOLATED POWER AND GROUND PANEL
<br /> ���� 1WDUP�EX PSHALL BE ISOLATED GROUND,v�ORANGE.� T E� 0 HER LEL BLADE.
<br /> L�]' ENCLOSED CIRCUIT BREAKER SIZE AS NOTED THREE DUPLEX SHALL BE NORMAL, IVORY. U.O.N. MOUNTED
<br /> IN PRESET FLOOR BOX. SEE NOTE #7.
<br /> � PRESET FLOOR BOX FOR CONNECTION TO SYSTEMS FURNITURE
<br /> PARTITION SEALTITE FLEXIBLE CONDUIT. SEE NOTE #8. www.brPh.com Copyrighto2016
<br /> � EQUIPMENT CONNECTION Architects, Engineers, Constructors
<br /> 19020 33rd Ave W,Suite 530 State of Washington
<br /> Lynnwood,Washington,98036 Certificate of Authorization
<br /> 425-921-3500 Architecture No.603235512
<br /> Engineedng No.3137
<br /> SYM REYISION BY APPROVED DATE SYM REYISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> � cAMA ACCEPTABILITY Vf6 07 27 16 ELECTRICAL LEGEND & ABBREVIATIONS � �
<br /> _ _ yti ' 8 THIS DESIGN AND/OR � 0 16321 O 0� 27 16
<br /> 0 Release 8 (IFC Wing Body Join WBS16321)(25-35) VTB DFC 07/27/16 q�,�w�F "'"�'1��,�'1� SPECIFICATION IS APPROVED SMS 07 27 16 SHEET
<br /> BOE,��� °L� 'S M��° � APPROVED BY DEPT. DATE pFc o� 2� �s TITLE FACTORY TRANSFORMATION 777X Wing Body Join �oA
<br /> CHECKED �8 O�
<br /> ��o�, Rg�i�'Q��,O ��`�'� APPROVED B U I LD I N G 4 0�O�V JOB N0. COMP N0.
<br /> WO 15 2899 - 800
<br /> �sS�ONAL �� APPROVED DWG N0.
<br /> ELECTRICAL MASTER EVERETf, WA 45-035-EOA-800
<br />
|