�c �r--
<br /> 119 119 1, 14 � 12 12 � � 1 � o
<br /> GE�JERAL �JOTES
<br /> I I 1. CONDUIT: 1/2" MINIMUM, 3/4" MINIMUM FOR ALL
<br /> I I I I HOMERUNS.
<br /> � 2. UNLESS OTHERWISE NOTED, WIRING ABOVE GRADE AND IN
<br /> DRY LOCATIONS SHALL BE THHN OR THHN/THWN-2 2#12
<br /> CU, 1#12 CU GROUND IN 3/4" CONDUIT.
<br /> — — — — - — — — — — — . — — — — _ _ � � 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH
<br /> \� DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH
<br /> COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE.
<br /> MATCHLINE - FOR CONTINUATION SEE SHEET 1 E113 � I IDENTIFY INSULATED GROUND CONDUCTORS IN ACCORDANCE
<br /> '�"— -- --�'�-- —"—"�"�' -- -- -- -- -- -- -- -- —I�--1-----�---- -- -- --- -- -- WITH NEC (USING TAPE). COLOR CODE AS FOLLOWS:
<br /> I I � I
<br /> 208Y 120V 480Y 277V
<br /> � � I I I I ( A� (LEFT BUS IN PNL) BLACK BROWN
<br /> � I I I I I I I I � B� (CENTER BUS IN PNL) RED ORANGE
<br /> I I I I I I I I ( C� (RIGHT BUS IN PNL) BLUE YELLOW
<br /> NEUTRAL WHITE GRAY
<br /> I I I I I I I I EQUIPMENT GROUND GREEN GREEN
<br /> I I I I I I I I � I ISOLATED GROUND GRN/YEL* GRN/YEL*
<br /> � I I I I ( *GREEN WITH YELLOW TRACER
<br /> � � � � � � I
<br /> � � � 4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND
<br /> I I I I I I I I SWITCH WITH CIRCUIT IDENTIFICATION.
<br /> I I I I I I I I 5. POST NEW OR REVISED PANEL SCHEDULES UPON
<br /> I I I I I I I I COMPLETION OF JOB.
<br /> � I I I ( I I I I i 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES
<br /> AS DETAILED.
<br /> � � � � � � � � � � �
<br /> I I ( I � � O 7. UNLESS OTHERWISE NOTED, RECEPTACLES SHALL BE NEMA
<br /> ' � � TYPE 5-20R, AND MOUNTED AT 48"AFF IN SHOP AREAS,
<br /> � � I I I I I I I I 18" AFF IN OFFICES, AND 48" AFF FOR HOUSEKEEPING
<br /> I I I I I I I I � RECEPTACLTES.
<br /> ' � � � � � � � � �
<br /> I
<br /> I i I i II II �
<br /> II II � � II II
<br /> � i � ii ii ii ,
<br /> � � � � � � � „ „ ' � � C� �ISTRUCT10 �1 NOTES
<br /> I I I I I I I I 1� FOR TEMPORARY RE-FEED, RECONNECT PARTIALLY
<br /> I I I I ( I I DEMOLISHED CIRCUITS SHOWN FROM 4V35-2M12 AND
<br /> I I I I � � 4V35-241 -1 TO SAME BREAKER OR NEXT AVAILABLE IN
<br /> NEW PANEL 4V35-2M12.5 AS INDICATED. REUSE CONDUIT
<br /> I I I I I I '�' I I WHERE POSSIBLE. EXTEND CONDUIT AND CONDUCTORS TO
<br /> � I I I I I � 0 � ; � NEW PANEL LOCATION. MAINTAIN CIRCUIT CONTINUITY AND
<br /> � � I I I I i � FUNCTIONALITY THROUGHOUT THE PROJECT AREA DURING
<br /> ALL PHASES OF CONSTRUCTION.
<br /> II II il II
<br /> � II II II I �
<br /> ' � II II I III
<br /> � � � � 1/ 4V35-2M12.5 1 a� II 30KVA TR NSFORMER
<br /> �4V35-2M12.5/13abc 3/4 C — 3#8 1 1/2"C,�#3 '
<br /> � I � � � � 3/4"C — 3#10,1#lOG I � I 240VL3�L.7i 12.5
<br /> z � � � � � � � � � I
<br /> I � I �4V35-2M12.5/12abc UP TO 3 D DECK AHU-5 (
<br /> Q I � � � � 3/4"C — 3#10,1#10G � � �
<br /> �
<br /> � � � � � � -- _- , �
<br /> _ _
<br /> — — a�
<br /> � AFDE — o ' I - — --� ;AHU 5 , —. _ _ �!C 1 � - -
<br /> N � � � � ���i - -� i�� - �i i� �i i; ��II � I i i �1� � - -� �� � ("� �� 11 11 12 13 14 15 16 17
<br /> o �r ,, �I � �'�;�' � L ' I � � _ ' � �
<br /> I ' 30 � �� ;i �i ��j i� � ��i � -; r�� �,, _ -- _ _ _ � _ �_ . � , � � �
<br /> �� �� I I I I � i � Ee ��co��ECTOR �! j� ;, ;I �,�I I � i� f; � ��� � � � � � �
<br /> � , � � � �
<br /> i � � ;�, ; ; ; � �' ' ', �� � B G 0- 3
<br /> � �� ' ' �' , , �, LD 4 0 4-� ,
<br /> � � I I I I , ----I I --� I I '�� �; ,; ''j ', �, �Tr— - �� I!-___ --_ _ '' ___ ' __--� I I � i I I I
<br /> z � � �; ;', �i Ij `' �I I,;i , ; _�; � �� � � I �—U
<br /> — I '
<br /> � I I I I � �, ,, ,,i ; , �, , — - ` -_ _- ---�-_ -- __�
<br /> � I I � —:-- -�-I ---_ _�_��'� ' I� ; I; i� ;; i ; ! II ; � K
<br /> �
<br /> � �,; , ,; �� �, — — --- -
<br /> —,
<br /> ' �' ' ��i� i i ! � � ;i � /"�
<br /> ,
<br /> i�
<br /> , ,
<br /> m � � � � � l� � L �I � � � �a-�� _, ==--I r—,i I- _-- -- �__� ___ �� -- -- -----------{ L J
<br /> — . _ _ _ _— — __ _- -
<br /> �, �_ � , —
<br /> _ _ _ _ � 9 i � � �./
<br /> (' i, Ii -- T -- :i ��� � � � li i
<br /> w — a�'�� �! ,i i', �' i I'��--��i; ; Ii� III Ir
<br /> � � � - , � � - - � �n � 2E�13 2E114j
<br /> � I I I I � � i ---- -_�-�-- --Ll=., , �, , �� �� � �
<br /> j !; j ;, ; �� �i I� ii�� — ��ii I a�--- --- )' I � � -- � � � ---------- L.3
<br /> � � � � � � � << � � `' ��i ' ��� —'u � � I L � �
<br /> z I I I I I ; �� �; ,,� � �, �__- -- -_��-�-_ �-__ �,
<br /> � I � �� ' �� ' �, �� �' �I���—��i � '--' � ' -i� �� �� � 2E 16 2E117�
<br /> �! !'' i' --�', : ' �
<br /> ¢ � � I =�_�___--.��_ i �,�, �' ' � -- �-- -� ��
<br /> � � -- -'� ; �� � I i f� �� � i� � i �� �f --- - � -- � -- - _ �_�- � -- ' ---------- L.7
<br /> � I '�I K�
<br /> � � � � � i � � � � � ; �� � � � _ � i �-�- �---
<br /> , ' � II �� ,! ! ,��� -k�j � i 'J � I i i � � �
<br /> I I I I - - --- - I � II -- '� �;� =� �1 � ------I------- ---- - ----- � 2E 19 2E12d) - --
<br /> o -- _ _� �- - _ ' i -- ----- -
<br /> � ' ' m
<br /> �
<br /> � � � i� �_ _� � � � ; � �
<br /> I I ;� .�-- -�-I I �/�.�I- -�- -;i --�r ,, ;�-- i' i � � ; ' ' 2E 22 2E12 !�
<br /> _ --
<br /> _ — � � �� ��� � ��i�"�'�� � � � I 1
<br /> � r � I I I I � � ; I I I I �,, I ,� �; i; ,i !!� ��� -_ - _���,;I �;�,' � � -- � I I -----------�
<br /> `�O ( I � __-- __-_ �' �i � �' ' ' I, ��
<br /> � ( I I i —1=I�= =�=1=�� i' ii ;; �; ;; � ,� - -- 1 C �-' I �� � �BLDG 40-036
<br /> W � i I I I � I I I I � � '' !j �' ' �' � �! ! ' �'�'�
<br /> � I i ,i u �i __� � I i q
<br /> i i; �I I ; I r--- i , �
<br /> I� i �
<br /> � � � � � � �� � -- I + � , � ��. � � ��
<br /> _ � I-� -=f=�=, i--- ��-— --��------L�--- I-- I�-- 1 1� I ! ' i �'� �
<br /> z � I I III I KEY PLAN
<br /> ----
<br /> �
<br /> ' — � ;
<br /> Q � I I I I I I I I I�, - - - � �-- � ---- -�1 � �� ��!--t � I SCALE: NONE N
<br /> I ' -
<br /> � --,-- - - I-I-- - -I-- I- - - - - - - - - - _- -_= _--- _-�i�, _ �{� _ � � �; �� _ 8 4 8 16
<br /> , �
<br /> i-1=—�1= � -;- � , , 0 4, , ,
<br /> � � I I � I I � � � � �� _- _ � � �
<br /> I I I I i r � � ';i � � � ;�� i
<br /> - , - - ----
<br /> i�,i, ; �:, , i ; ; i, � i
<br /> -- -- --��---- --�11— -- -- -- -- -- -- � -- -- � �I-�i r� I=I=;�.i�— ' -- -- �� -- � � --i�����-- -- sca�E: �/8»=� ,_o»
<br /> MATCHLINE - FOR CONTINUATION SEE SHEET 1 E119
<br /> PARTIAL SECO �ID FLOOR 480Y 277� POWER P �A�I WWw.brph.com Copyrighto2016
<br /> SCALE: 1/8"=1 '-0" N Architects, Engineers, Constructors
<br /> 19020 33rd Ave W,Suite 530 State of Washington
<br /> Lynnwood,Washington,98036 Certificate of Authorization
<br /> 425-921-3500 �'�itecture No.603235512
<br /> Engineering No,3137
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DA SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> ACCEPTABILITY VTB 07 27 16
<br /> 0 Release 8 — (IFC Wing Body Join — WBS16321)(25-35) VTB DFC o��2��,s ��.�� CAMA� THIS DESIGN AND/OR EMOVAL TEMP PARTIAL 2ND FL04R 48QY1277V POWER PLAN � 632� 0�/2�/� 6
<br /> W�Sy, �
<br /> qQ',��,°F ��, l� SPECIFICATION IS APPROVED SMS 07 27 16 sHEEr
<br /> BOE���� 03 38P �.2 ��, APPROVED BY DEPT. DATE gL6 0� 2� �s T��"E FACTORY TRANSFORMATION 777X Wing Body Join
<br /> � _ .� �HE�KEQ 2 E 116 RT -800
<br /> � A� �� ww BUILDING 40 035
<br /> �.��.ss�1sTER��,ti� APPROVEO - �oB NoiNO 15/2899 - 800 COMP N0.
<br /> IONAL
<br /> APPRovEo ELECTRICAL MASTER COL. L.3-L.7/11 -13 EVERETT, Wq owc ►vo. 40-035-2E116RT-800
<br />
|