My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1871 ROSS AVE VERIZON ANTENNA 2018-05-30
>
Address Records
>
ROSS AVE
>
1871
>
VERIZON ANTENNA
>
1871 ROSS AVE VERIZON ANTENNA 2018-05-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2018 2:04:19 PM
Creation date
5/30/2018 2:04:14 PM
Metadata
Fields
Template:
Address Document
Street Name
ROSS AVE
Street Number
1871
Tenant Name
VERIZON ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Verizon TAC SEA Dagmar—17048.214 September 18,2017 <br /> Structural Analysis Report Page 4 of 4 <br /> TOWER FOUNDATION ANALYSIS RESULTS <br /> The analysis performed on the foundation system was based on the original drawings provided to us. <br /> These drawings describe the maximum loads used for the design which are listed in the table below. In <br /> comparing our calculated values with the design loads,we determined that all of the proposed loads <br /> remain less than the design loads stated,and therefore the foundation system should be adequate as <br /> originally designed. <br /> Foundation Reaction Summary <br /> Design Values Calculated Values <br /> Moment(kip-ft) 1310 487 <br /> Shear(kips) 16 7.3 <br /> Axial(kips) 16 13.7 <br /> CONCLUSIONS/RECOMMENDATIONS <br /> We have determined that this monopole complies with the ANSI/TIA-222-G Standard. No upgrades are <br /> required for the proposed Verizon Wireless antenna configuration described above. All monopole <br /> sections,connections,and the foundation system are within their allowable capacities for the applied <br /> loads. <br /> CONDITIONS OF ANALYSIS <br /> This structural analysis is based on the documentation that was available to us. CG Engineering did not <br /> perform an observation of this site to verify the accuracy of the provided structure and appurtenance <br /> data,and we should be contacted immediately if there are any discrepancies with the information <br /> stated within this report. <br /> Our analysis is based on the assumption that the original structural design and all subsequent structural <br /> analyses were properly designed and permitted per the applicable building codes,and that the structure <br /> has been properly installed and is maintained to the minimum standards required by code. We assume <br /> the structure has no known deterioration or damage that would adversely affect its capacity. <br /> REFERENCE DOCUMENTS <br /> The following documents were provided to us by the Client for our analysis. Excerpts from these <br /> documents have been included at the end of this report. The full documents can be obtained from the <br /> Client. <br /> 1. "Communications Structure Nonlinear Analysis and Desian Program",erection drawings by <br /> Engineered Endeavors Inc.,dated 10/26/2006 <br /> ©� 250 4th Avenue South,Suite 200 <br /> Edmonds,WA 98020 <br /> ENGINEERING ph.425.778.8500 i f.425.778.5536 <br /> www.cgengineering.com <br />