Laserfiche WebLink
CHASE � 1 <br />EVERETT MALL WAY <br />2016 PATH OF TRAVEL <br />10012 1ST DR. SE <br />EVERETT WA.. 98208 <br />CHASE # 10074 <br />GENERAL NOTES <br />1. ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL BUILDING <br />CODES, REGULATIONS, ORDINANCES AND STANDARDS INCLUDING ADA AND OR OTHER <br />ACCESSIBILITY CODES. <br />2. GEN. CONTRACTOR SHALL COORDINATE WITH THE OWNER'S VENDORS REGARDING <br />SCHEDULING AND SEQUENCING OF THE WORK. <br />3. THE CONSTRUCTION NOTES AND DRAWINGS ARE SUPPLIED TO ILLUSTRATE THE DESIGN AND <br />GENERAL TYPE OF CONSTRUCTION DESIRED AND ARE INTENDED TO IMPLY THE FINEST QUALITY <br />OF CONSTRUCTION, MATERIAL AND WORKMANSHIP THROUGHOUT. <br />4. THE DRAWINGS ARE NOT TO BE SCALED. FOR INFORMATION CONCERNING EXISTING <br />CONDITIONS, ETC., VERIFICATION MUST BE DONE IN THE FIELD. LARGE SCALE DRAWINGS <br />HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. <br />5. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION, CONTRACTOR SHALL VERIFY EXISTENCE <br />AND LOCATION OF ALL EXISTING ABOVE AND BELOW GRADE, UTILITIES, INCLUDING SANITARY <br />SEWER, STORM SEWER, WATER, GAS, ELECTRICAL, TELEPHONE, ETC. ANY DISCREPANCIES IN <br />UTILITY LOCATIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. <br />6. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL BUILDING AND SITE <br />DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION AND SHALL IMMEDIATELY NOTIFY THE <br />ARCHITECT OF ANY VARIANCE OR DISCREPANCY AFFECTING NEW CONSTRUCTION PRIOR TO <br />PROCEEDING WITH WORK. <br />7. CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING IN WALLS FOR SUPPORT OF ALL <br />EQUIPMENT, SHELVING, ACCESSORIES, SIGNAGE, AND OTHER DEVICES REQUIRED. <br />8. ALL PENETRATIONS SHALL RECEIVE CAULKING TO SEAL ANY TYPE OF ENERGY LOSS. <br />9. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS OF <br />FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS. <br />10. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL <br />JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND <br />CERTIFICATES OF OCCUPANCY. <br />11. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES AND ANY <br />SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED <br />IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT <br />12. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE OWNER'S VENDORS ON <br />SITE DURING CONSTRUCTION. REFER TO RESPONSIBILITY MATRIX THIS SHEET. <br />13. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SET-UP AND COORDINATION OF ALL THE <br />UTILITY SERVICES FOR THE PROJECT. <br />14. ALL CONSTRUCTION VEHICLES SHALL BE EQUIPPED WITH THE MOST MODERN NOISE MUFFLERS <br />AVAILABLE AND ALL ENGINES SHALL BE KEPT PROPERLY TUNED. <br />15. GENERAL CONTRACTOR TO PROVIDE EFFECTIVE MEANS OF DUST CONTROL FOR THE SITE, SO <br />AS NOT TO CREATE UNFAVORABLE CONDITIONS THROUGHOUT THE DURATION OF <br />CONSTRUCTION AND MEET THE REQUIREMENTS OF LOCAL CODES AND ORDINANCES. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING REQUIRED PERMITS. <br />16. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL DURING <br />CONSTRUCTION. <br />PROJECT INFORMATION <br />SCOPE OF WORK <br />*NO PLUMBING OR MECHANICAL WORK <br />* EXTERIOR WORK FOR BARRIER REMOVAL: <br />RELOCATE ACCESSIBLE PARKING STALLS <br />REMOVE AND REPLACE PORTION OF THE ASPHALT AT RELOCATED ACCESSIBLE PARKING STALLS <br />RESTRIPING OF ACCESSIBLE PARKING SPACE <br />INSTALLATION OF REQUIRED ACCESSIBLE SIGNAGE <br />REMOVE AND REPLACE A PORTION OF THE CONCRETE SIDEWALK ADJACENT TO THE BRANCH <br />ENTRANCE <br />* INTERIOR SCOPE: <br />ADJUSTMENTS AND ADD DOOR HARDWARE FOR ADA COMPLIANCE <br />REQUIRED SIGNAGE <br />V <br />JURISDICTION: <br />EVERETT <br />APM-00396900003000 � O� <br />REFERENCE CODES: / <br />/BUILDING CODE: 201? IBC - CHAPTER 51-50 WAC <br />MECHANICAL CODE: 20!12 IMC CHAPTER 51-52 WAC i <br />PLUMBING CODE: 2f012 UPC CHAPTER 51-56 AND 51-57 WAC <br />ELECTRICAL CODE: C (K a E�-C'tI <br />(THRU-WA STATE -LABOR`- y?c'C? �i`1 <br />AND INDUSTRY): 2014 NEC & WAC 296-46-B-010 <br />FIRE CODE: 2011 IFC & WAC 51-52 <br />ENERGY CODE: 2 012 IECC - CHAPTERS 51-11 <br />_ACCESSIBILITY CODE: ICC/ANCI Al 17.1 & WAC 51-51-005 <br />OCCUPANCY CLASSIFICATION: - <br />EXISTING / PROPOSED USE: RETAIL BANK - BUSINESS GROUP B (EXISTING, NO CHANGE) <br />EXISTING BUILDING AREA: <br />CHASE BANK: 2,975 S.F. (EXISTING, NO CHANGE) <br />TYPE OF CONSTRUCTION (CHAPTER 6): <br />V -B, NON-SPRINKLERED <br />OCCUPANT LOAD (TABLE 1004.1.2): <br />OCCUPANT LOAD FACTOR: 1/100 2,975 SQ. FT. / 100 SQ. FT. = 29.75 <br />TOTAL OCCUPANT LOAD: 30 OCCUPANTS (EXISTING, NO CHANGE) <br />EGRESS WIDTH (SECTION 1005.3.2): <br />B OCCUPANCY WITHOUT SPRINKLERS <br />MIN. EXIT WIDTH REQUIRED: 30 OCCUPANTS X 0.2 = 6 <br />EXIT WIDTH: 6" REQUIRED <br />118" PROVIDED (EXISTING, NO CHANGE) <br />EXITS (SECTION 1015.1): _ <br />EXITS REQUIRED: 1 (<30 OCCUPANTS, MAX TRAVEL DISTANCE < 100') <br />17. WHEN ARCHITECTS, CIVIL ENGINEERS, CITY AND/OR COUNTY STANDARDS DIFFER, THE MORE <br />RESTRICTIVE SHALL PREVAIL. ALWAYS INFORM CONFLICTS TO THE ARCHITECT. <br />18. PROVIDE PEDESTRIAN OR VEHICULAR PROTECTION BARRICADES, TEMPORARY GUARD RAILS, <br />AND CANOPIES NECESSARY FOR PEDESTRIAN AND VEHICULAR SAFETY AS REQUIRED BY THE <br />LOCAL AUTHORITIES, SECTION 3306, IBC. <br />19. REFER TO LATEST VERSION OF CHASE PROJECT MANUAL FOR NECESSARY DESIGN FEATURES <br />AND SPECIFICATIONS. <br />20. ALL EXTERIOR FLOOR PLAN DIMENSIONS ARE TO EXTERIOR FACE OF MASONRY UNLESS <br />OTHERWISE NOTED. ALL INTERIOR FLOOR PLAN DIMENSIONS ARE TO FACE OF FINISH UNLESS <br />OTHERWISE NOTED. <br />21. DURING CONSTRUCTION SITE VISITS THE GC IS RESPONSIBLE FOR KEEPING MEETING MINUTES <br />AND SHALL PROVIDE COPIES OF RFI LOGS, UPDATED CONSTRUCTION SCHEDULE WHICH <br />SHALL ALSO INCLUDED AN ITEMIZED 3 WEEK OUTLOOK SCHEDULE. <br />22. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS <br />TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL -BOXES, <br />TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC) OR TO THE <br />LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY <br />POWER LINES -WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO <br />COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. <br />23. ALL WORK IS NEW UNLESS INDICATED AS EXISTING. <br />24. ALL CONSTRUCTION SHALL BE VERIFIED TO BE IN COMPLIANCE WITH THE LOCALLY ADOPTED <br />ACCESSIBILITY REGULATIONS. ANYTHING FOUND NOT IN COMPLIANCE SHALL BE REPLACED AT <br />THE CONTRACTOR'S EXPENSE. ALL SLOPES SHALL BE MEASURED WITH A 24 INCH SMART LEVEL" <br />PROVIDED: 2 (EXISTING, NO CHANGE) <br />EXIT SEPARATION (SECTION 1015.2.1) <br />NON-SPRINKLERED BUILDINGS: ONE HALF OF THE LENGTH OF MAXIMUM OVERALL DIAGONAL <br />*BUILDING DIAGONAL= 75-6" (1/2 DIAGONAL LENGTH = 37'-7 1/2") <br />*EXIT SEPARATION PROVIDED= 61'- 1" (EXISTING, NO CHANGE) <br />MAX TRAVEL DISTANCE (TABLE 1016.2) <br />MAX TRAVEL DISTANCE WITHOUT SPRINKLERS: =200'-0" <br />*PROJECT MAX. TRAVEL DISTANCE PROVIDED = 65'-11 3/8" < 200'-0" <br />ACCESSIBILITY: <br />ALL WORK WITHIN THE SCOPE OF THE PROJECT SHOWN ON THESE PLANS COMPLIES WITH ADA BARRIER <br />REMOVAL REQUIREMENTS FOR 2009 ICC/ANSI <br />PARKING (EXISTING): <br />STANDARD PARKING STALLS: 55 <br />ACCESSIBLE PARKING STALLS: 3 <br />PLUMBING FIXTURE COUNT (SECTION 2902.1): <br />ALL EXISTING PLUMBING FIXTURES ARE EXISTING TO REMAIN. THE WORK TO BE DONE WITHIN THE SCOPE OF THIS <br />PROJECTS DOES NOT EFFECT THE PLUMBING FIXTURE CODE REQUIREMENTS FOR THIS BUILDING. <br />EGRESS PLAN <br />COMMON <br />PATH OF EGRESS <br />0 -- 0 -- -- <br />nn <br />_J C.) _J J <br />® O A 60 I c� L w 6A N- <br />m ®® ®® ®® I LU Ly <br />AX. TRAVEL <br />�- �:_ MAX. <br />_---------� <br />PROVIDED: 39'-11 Z" <br />F_ c _ a. <br />LU (COMMON MAX. TRAVEL <br />PATH DISTANCE <br />F EGRESS) ALLOWED: 200'-0" nrM <br />N 1 <br />0 <br />T <br />m °o <br />® s MAX. TRAVEL <br />o° DISTANCE <br />PROVIDED: 65-118" <br />MAX TR -------------- <br />s > <br />f� <br />AVEL <br />DISTANCE <br />PROJECT OWNER: <br />GENERAL ABBREVIATIONS <br />ALLOWED: 200'-0" t +y <br />KIMLEY HORN <br />EAX.i <br />TRAVEL l <br />INSUL <br />a <br />- <br />DISTANCE <br />AIR CONDITIONING <br />ti <br />PROVIDED: 35'-3" a„NG <br />> <br />ACOUSTIC CEILING TILE <br />w <br />MAX. TRAVEL _ <br />v <br />N <br />0 41 - <br />AFF <br />DISTANCE DISTANCE <br />-N <br />MANUFACTURER <br />ALLOWED: 200'-0" <br />w <br />o <br />MINIMUM <br />AL <br />o <br />MO <br />MASONRY OPENING <br />ABBREVIATIONS <br />REVIEWED <br />PROJECT OWNER: <br />GENERAL ABBREVIATIONS <br />JP MORGAN CHASE BANK, N.A. <br />KIMLEY HORN <br />A <br />ANNEALED <br />INSUL <br />INSULATION <br />AC <br />AIR CONDITIONING <br />MAX <br />MAXIMUM <br />ACT <br />ACOUSTIC CEILING TILE <br />MECH <br />MECHANICAL <br />AFF <br />ABOVE FINISH FLOOR <br />MFR <br />MANUFACTURER <br />AHU <br />AIR HANDLING UNIT <br />MIN <br />MINIMUM <br />AL <br />ALUMINUM <br />MO <br />MASONRY OPENING <br />ASPH <br />ASPHALT <br />MR <br />MOISTURE RESISTANT <br />CJ <br />CONTROL JOINT <br />MTL <br />METAL <br />CLNG <br />CEILING <br />NA <br />NOT APPLICABLE <br />CMU <br />CONCRETE MASONRY UNIT <br />NIC <br />NOT IN CONTRACT <br />COL <br />COLUMN <br />NOM <br />NOMINAL <br />CONC <br />CONCRETE <br />NTS <br />NOT TO SCALE <br />CONT <br />CONTINUOUS <br />OC <br />ON CENTER <br />CPT <br />CARPET <br />OPP <br />OPPOSITE <br />CT <br />CERAMIC TILE <br />PF <br />PRE -FABRICATED <br />CL <br />CENTERLINE <br />PSF <br />POUNDS PER SQUARE FOOT <br />DBL <br />DOUBLE <br />PT <br />PRESSURE TREATED <br />DF <br />DRINKING FOUNTAIN <br />PTD <br />PAINTED <br />DIA <br />DIAMETER <br />QT <br />QUARRY TILE <br />DIM <br />DIMENSION <br />R <br />RADIUS <br />DN <br />DOWN <br />REBAR <br />REINFORCING BAR <br />DS <br />DOWNSPOUT <br />REF <br />REFERENCE <br />EA <br />EACH <br />REQ'D <br />REQUIRED <br />EJ <br />EXPANSION JOINT <br />RO <br />ROUGH OPENING <br />ELEC <br />ELECTRICAL <br />SF <br />STOREFRONT <br />ELEV <br />ELEVATION <br />SB <br />SPLASHBLOCK <br />EQ <br />EQUAL <br />SIM <br />SIMILAR <br />EXIST <br />EXISTING <br />SPEC <br />SPECIFICATION <br />FD <br />FLOOR DRAIN <br />SS <br />STAINLESS STEEL <br />FE <br />FIRE EXTINGUISHER <br />STL <br />STEEL <br />FEC <br />FIRE EXTINGUISHER CABINET <br />STOR <br />STORAGE <br />FF <br />FINISH FLOOR <br />SUSP <br />SUSPENDED <br />FR <br />FIRE RATED <br />T <br />TEMPERED <br />FRP <br />FIBERGLASS REINFORCED PLASTIC <br />TYP <br />TYPICAL <br />GALV <br />GALVANIZED <br />UNO <br />UNLESS NOTED OTHERWISE <br />GYP BD <br />GYPSUM BOARD <br />VCT <br />VINYL COMPOSITION TILE <br />HC <br />HANDICAP <br />VERT <br />VERTICAL <br />HDW <br />HARDWARE <br />WD <br />WOOD <br />HM <br />HOLLOW METAL <br />WP <br />WATERPROOF <br />HT <br />HEIGHT <br />WWF <br />WELDED WIRE FABRIC <br />HVAC <br />HEATING,VENTILATION, AIR CONDITIONING <br />CHASE ABBREVIATIONS <br />ABCM <br />ASSISTANT BANKING CENTER MANAGER <br />FAB <br />FULL ACCESS BAR (FORMERLY 'AB-) <br />AFF <br />AFFLUENT <br />HUB <br />HOLD-UP BUTTON <br />AHD <br />AFTER -HOUR DEPOSITORY <br />LAB <br />LITE ACCESS BAR <br />AST <br />ACCESSIBLE SERVICE TELLER <br />MST <br />MERCHANT SERVICE TELLER <br />ATM <br />AUTOMATIC TELLER MACHINE <br />MFD <br />MULTI -FUNCTIONAL DEVICE <br />BCM <br />BANKING CENTER MANAGER <br />MM <br />MASS MARKET <br />BFW <br />BRAND FOCAL WALL <br />PB <br />PERSONAL BANKER <br />BRG <br />BULLET -RESISTANT GLASS <br />PCA <br />PRIVATE CLIENT ADVISOR <br />BWC <br />BLUE WALL COVERING <br />PCB <br />PRIVATE CLIENT BANKER <br />CAT <br />CUSTOMER ACCESS TABLE <br />PCIA <br />PRIVATE CLIENT INVESTMENT ADVISOR <br />CCR <br />CUSTOMER CONFERENCE ROOM <br />PR <br />PACKAGE RECEIVER <br />CPC <br />CHASE PRIVATE CLIENT <br />PST <br />PRIVATE SERVICE TELLER <br />CR <br />CASH RECYCLER <br />RG <br />REACH GUARD <br />CSC <br />CUSTOMER SERVICE CENTER <br />SCCR <br />SMALL CUSTOMER CONFERENCE ROOM'. <br />DRC <br />DESIGN REVIEW CALL <br />SDB <br />SAFE DEPOSIT BOX <br />DU <br />DRIVE -UP <br />TCD <br />TELLER CASH DISPENSER <br />eATM <br />eAUTOMATIC TELLER MACHINE <br />TOS <br />TEAM OFFICE SPACE <br />VAT <br />VACUUM AIR TUBE <br />APPROVED <br />PLANNING & COMMUNITY <br />DEVELOPMENT DEPT. <br />B lt� <br />DATE <br />APPROVED <br />PUB=VRKSD1EAR�'�AENT <br />BY - <br />DATE <br />CITY OF EVE 1120 <br />EVERETT �EVItWED FOR. PERMIT <br />OWNER & CONSULTANTS <br />REVIEWED <br />PROJECT OWNER: <br />CIVIL ENGINEER: <br />JP MORGAN CHASE BANK, N.A. <br />KIMLEY HORN <br />LISA JONES <br />765 THE CITY DRIVE, STE. 200 <br />CHASE/CBRE/GLOBAL CORPORATION SERVICES <br />ORANGE, CA 92868 <br />201 NORTH CENTRAL AVENUE, 25TH FLOOR <br />CONTACT: JOHN POLLOCK <br />PHOENIX, AZ 85004 <br />EMAIL: JOHN.POLLOCK@KIMLEY-HORN.COM <br />EMAIL: LISA.R.JONES@CHASE.COM <br />PHONE: (714) 786-6125 <br />WORK: (602)-221-1922 <br />N <br />FAX: (602)-680-1496 <br />OX <br />MOBILE: (602)-826-3073 <br />W 0E <br />BDGLLP <br />JPMORGAN CHASE REAL ESTATE <br />131 SOUTH DEARBORN, 5TH FLOOR <br />MAIL CODE: IL1-0930 <br />CHICAGO, IL 60603 <br />EMAIL: SARAH.JAMES@BDGLLP.COM <br />WORK: (813)-323-9233 <br />MOBILE: (813)-225-7222 <br />ARCHITECT: <br />STANTEC ARCHITECTURE <br />8211 SOUTH 48TH STREET <br />PHOENIX, AZ 85044 <br />CONTACT: ANNETTE ZACHERSON <br />EMAIL: ANNETTE.ZACHERSON@STANTEC.COM <br />PHONE: (602) 707-4778 <br />FAX: (602) 431-9562 <br />JURISDICTION CONTACTS <br />CITY OF EVERETT BUILDING DEPARTMENT <br />3200 CEDAR STREET, 2ND FLOOREVERETT, WA <br />96201 <br />PHONE: (425) 257-8810 <br />WEBSITE:WWW.EVERETTWA.GOV/342/PLANNING-COMMUNITY-DEVELOPMENT <br />HOURS: M -F 7:30 -NOON -1-4 <br />CONTACT NAME: STEVE MILLERTITLE: <br />PLAN REVIEWER <br />PHONE: (425) 257-7264 <br />EMAIL: SMILLER@EVER ETTWA.GOV. <br />SYMBOLS <br />REVIEWED <br />FOR PERMIT <br />X <br />CONSTRUCTION TYPE <br />ELEVATION <br />0'-0" <br />ELEVATION DATUM TAG <br />> <br />PROJECT INFORMATION BLOCK <br />1` <br />4 <br /># <br />REVISION NUMBER <br />X <br />AX.X <br />DETAIL TAG <br />AO.0 <br />COVER SHEET <br />N <br />AO.1 <br />OX <br />GRID BUBBLE <br />W 0E <br />DEMOLITION PLAN <br />• <br />C2.0 <br />IMPROVEMENT PLAN <br />INTERIOR ELEVATION TAG <br />C3.0 <br />DETAILS <br />S <br />AO.2 <br />FINISH <br />FINISH TAG <br />AO.3 <br />ACCESSIBILITY DETAILS <br />• • <br />AO.4 <br />ACCESSIBILITY DETAILS <br />W W <br />A1.1 <br />FLOOR PLAN <br />X <br />EXTERIOR ELEVATION TAG <br />EQ <br />EQUIPMENT TAG <br />AX.X <br />1 <br />/AX• <br />MATCH LINE <br />NAME <br />r <br />### <br />ROOM TAG <br />N <br />X <br />PLAN DETAIL TAG <br />###A <br />DOOR TAG <br />AX.X <br />OX <br />WINDOW TAG <br />X <br />AX.X <br />WALL SECTION TAG <br />KN <br />KEYNOTE <br />X <br />BUILDING SECTION TAG <br />AX.X <br />RESPONSIBILITY MATRIX NOTES <br />1. SIGNAGE TO INCLUDE DIRECTIONAL SIGNAGE, AND MAIN BUILDING LETTER SET. GENERAL <br />CONTRACTOR TO PROVIDE CONDUIT, ROUGH -IN & FINAL ELECTRICAL CONNECTIONS. <br />SHEET IN D Wpermit review does not cover <br />[Ftsaeral ADA, FHA or HUD regulations <br />REVIEWED <br />FOR PERMIT <br />and s an ar s, including the <br />Fair Housing Accessibility Guidelines. <br />Compliance with those regulations is the <br />responsibility of the owner of the building. <br />DRAWINGS ISSUED <br />0 <br />N <br />0 <br />0 <br />> <br />PROJECT INFORMATION BLOCK <br />1` <br />4 <br />DATE: 12-14-2016 <br />0 <br />ARCHITECTURAL DRAWINGS <br />>- ab <br />AO.0 <br />COVER SHEET <br />• • <br />AO.1 <br />SITE PLAN <br />0 <br />C1.0 <br />DEMOLITION PLAN <br />• <br />C2.0 <br />IMPROVEMENT PLAN <br />~ <br />C3.0 <br />DETAILS <br />• • <br />AO.2 <br />ACCESSIBILITY DETAILS <br />r � <br />�N� <br />AO.3 <br />ACCESSIBILITY DETAILS <br />• • <br />AO.4 <br />ACCESSIBILITY DETAILS <br />W W <br />A1.1 <br />FLOOR PLAN <br />> > <br />W W <br />x <br />v <br />r <br />O <br />N <br />TOTAL <br />9 SHEETS <br />LOCATION MAP <br />19 111116 <br />M <br />NOT TO SCAL <br />RESPONSIBILITY MATRIX - OVERALL <br />ITEM FURNISHED/ FURNISHED / FURNISHED BY COORDINATED <br />INSTALLED BY INSTALLED BY OWNER/ BY GENERAL <br />OWNER'S GENERAL INSTALLED BY CONTRACTOR <br />EQUIPMENT CONTRACTOR GENERAL (GC) <br />CONTRACTOR (GC) CONTRACTOR <br />(GC) <br />Permit#: B1701-044 <br />Site Address: 100121ST DR SE <br />Owner: JPMORGAN CHASE BANK NA <br />Tenant: CHASE BANK <br />App. Date: 1/31/2017 <br />Proposed Use: PARKING LOT <br />Description: PARKING LOT, DOOR HARDWARE <br />ALTERATIONS FOR ACCESSIBILITYT <br />Reviewed By: lY166 t-6 `"' IT _ ! Date: d ) <br />Office Set Job Site Set Fire/Plannii <br />N 06're"o Il,I 6(1� 0 E <br />Permit#: PW1701-030 <br />Site Address: 100121ST DR SE <br />Owner: 1PMORGAN CHASE BANK NA <br />Tenant: [TenNamej <br />App. Date: 1/31/2017 <br />Proposed Use: <br />Description: PARKING LOT ALTERATIONS FOR <br />ACCESSIBILITY v` <br />i' Reviewed By: - `�� &v <br />y , ate: c l <br />--r <br />,Office Set Jab Site Set Fire/Plar <br />CITY OF EVERETT <br />REVIEWED <br />FOR PERMIT <br />W <br />d' <br />> <br />PROJECT INFORMATION BLOCK <br />1` <br />4 <br />DATE: 12-14-2016 <br />0 <br />19 <br />>- ab <br />O <br />~ <br />Q y N <br />MODEL <br />• Go <br />I <br />L <br />J W <br />L <br />O <br />~ <br />W <br />_• <br />r � <br />�N� <br />A0,60 <br />HARDWARE <br />W r W <br />0 <br />U) <br />W W <br />a <br />a <br />> > <br />W W <br />x <br />v <br />r <br />O <br />N <br />ARCHITECT/ ENGINEER OF <br />RECORD <br />Stantec <br />Architecture Inc. <br />135 South LaSalle St., Ste 3100 <br />Chicago, IL 60603 <br />TEL. 312.262.2290 <br />www.stantec.com <br />Copyright Reserved <br />The Contractor shall verify and be responsible for all <br />dimensions. DO NOT scale the drawing - any errors or <br />omissions shall be reported to Stantec without delay. The <br />Copyrights to all designs and drawings are the property <br />of Stantec. Reproduction or use for any purpose other <br />than that authorized by Stantec is forbidden. <br />SEAL <br />/ �.''. f'F .'' !f .rF %✓' %s°/`J+ %!% F' '' !`% %�.� /� .rf a i <br />1 V'Y®ri <br />vREGIS'fERE <br />ARY M. SEMLING <br />STATE OF WASHINGTON <br />EXTERIOR BUILDING SIGNAGE (SEE NOTE 4) YES <br />' /Y <br />ISSUE I DATE I DESCRIPTION <br />12-14-2016 CHASE REVIEW <br />01-24-2017 ISSUED FOR PERMIT <br />INTERIOR BLDG. SIGNAGE (SEE NOTE 4) <br />NO <br />TEMPORARY CONSTRUCTION SIGN YES <br />PROJECT INFORMATION BLOCK <br />JOB # 2007696076 <br />DATE: 12-14-2016 <br />�` l°° 0% M/��, /MM/z <br />DRAWN BY: RB <br />CHECKED BY: AMZ/DR/SS <br />MODEL <br />I <br />SHEET TITLE <br />L <br />COVER SHEET <br />SHEET NUMBER <br />A0,60 <br />HARDWARE <br />/17 <br />Ig Set <br />tjC',P6!? <br />T_ <br />ning Set <br />