Laserfiche WebLink
BERC2 CLIP <br /> POP RIVET <br /> 2 x 2 SUPPLY 2 x 4 FLUORESCENT <br /> AIR DIFFUSER TROFFER <br /> r <br /> �n CROSS TEE CROSS TEE <br /> #8 x 1/2" ROUND WASHER <br /> HEAD TEK SCREW WALL ANGLE <br /> (SELF— TAPPING) <br /> N 0 TE: S C R E W I S N 0 T ---- -- -- —--. — —-- -- ---.._-- - —---- — ------ — —--- -- ----- ---_ <br /> WALL ANGLE TIGHTENED DOWN AGAINST . <br /> BERC2 CLIP <br /> � <br /> UNATTACHED WALL ATTACHED WALL <br /> (TWO ADJACENT WALLS) (TWO ADJACENT WALLS) � <br /> SEISMIC BERC2 CLIP <br /> —FACTORY INSTALLED AT TWO ADJACENT WALLS. <br /> � � <br /> —SCREW TIGHTENED FOR SHIPPING IN ROOMS WHERE i � <br /> CEILING CROSSES MOD LINE, LOOSEN SCREW ON SITE �_, <br /> BY SET UP CREW � <br /> SUSPENDED CEILING GRID BERC2 CLIPS M—� <br /> SEISMIC ATTACHMENT AT WALLS REFLECTED CEI LI NG PLAN <br /> 3" = 1'-0" [ARMSTRONG SEISMIC 'Rx' SUSPENSION <br /> SYSTEM (ESR 1308)] 1/8" = 1'-0" <br /> MECHANICAL NOTES: <br /> 1. DUCT MATERIAL IS 26 GA. GALV. AND FLEX DUCT. DUCTWORK SHALL BE SUPPORTED PER IMC <br /> CHAPTER 6. SECTION 603 <br /> 2. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25, SMOKE DEVELOPMENT <br /> OF 50 PER IMC CHAPTER 6. SECTION 602 <br /> SUPPLY AIR <br /> 3. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND PL.ENUM #PWS015 <br /> CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND SEALED WITH �2,�0 <br /> WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC—PLUS EMBEDDED—FABRIC SYSTEMS OR APPROVED TAPES 1 � 12 <br /> INSTALLED IN ACCORDANCE WITH THE MANUFACTURER�S INSTALLATION INSTRUCTIONS 10 0 12 <br /> 1 <br /> 4. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEN THEY SHALL COMPLY _�2'1� _ T- - <br /> WITH IMC CHAPTER 6 3 TON 10 kw <br /> HEAT PUMP <br /> 5. 10" DIFFUSERS WITH NO MANUAL DAMPERS. USE FLOW CONTROLS AT WYES, TYPICAL AS NOTED ON PLAN w/ ECONOMIZER <br /> 1100 cfm MAX <br /> 6. MINIMUM 390 CFM OUTSIDE AIR REQUIRED PER IMC CHAPTER 4 <br /> 7. OUTSIDE AIR DAMPERS SHALL COMPLY WITH WSEC <br /> 8. SINGLE PACKAGE UNITARY FAN COOLING UNITS HAVING A TOTAL COOLING CAPACITY OF GREATER THAN , <br /> 20,000 Btu/h REQUIRE ECONOMIZERS PER WSEC <br /> 9. THE BUILT—IN ECONOMIZER SYSTEM IS INTERNALLY MOUNTED BEHIND THE SERVICE DOOR AND AL�OWS <br /> UP TO 100� OUTSIDE AIR THRU THE AIR INLET OPENINGS. IT INCLUDES A BUILT—IN EXHAUST AIR <br /> DAMPER. THE ECONOMIZER IS DESIGNED TO PROVIDE "FREE COOLING" WHEN THE OUTSIDE AIR M EC HAN I CAL P LAN <br /> TEMPERATURE IS COOL ENOUGH TO PROVIDE NEEDED COOLING WITHOUT USING THE COMPRESSOR. <br /> THIS IN TURN PROVIDES LOWER OPERATING COSTS, WHILE EXTENDING THE LIFE OF THE COMPRESSOR <br /> 1/8" = 1'-0" <br /> QTY. SIZE DESCRIPTION <br /> H.V.A.C. 1 3 TON 10 kW BARD WALL HUNG HEAT PUMP w/ ECONOMIZER <br /> HONEYWELL w/ MICROPROCESSOR— 7 DAY PROGRAMMABLE <br /> INDOOR THERMOSTAT � VISIONPRO #TH8320U AUTOMATIC SETBACK— DEADBAND CONTROL <br /> OUTDOOR THERMOSTAT � CMH-14A <br /> COPYRIGHT 2016, BIAZER INDUSTRIES, iNc. � MODULAR Classroom for.� Approved for Const: Job No. 18567 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER WDUSTRIES, INC.AND SHALL �� 2$ X 32 KC DA - Eve rett S�D■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �� INDUSTRIES,INC. Drawn By: JWR � <br /> �� www.blazerind.com WA. GOLD Pacific Mobile 14 BLMP-11 A3 Everett WA <br /> DATE REVISION BY WRITfEN PERMISSION OF BLAZER INDUSTRIES. �� P.O.BOX 489 ■ Aumsville,OR 97325-0489 � Issue Date: 02/01/16 <br />