Laserfiche WebLink
MEANS O�`-'GRESS <br /> 1013.6.1 Graphics. Every exit sign and directional exit form,not less than 30 inches (762 mm) and not more than 34 <br /> sign shall have plainly legible letters not less than 6 inches inches(864 mm). <br /> (152 mm)high with the principal strokes of the letters not <br /> less than 3/4 inch(19.1 mm)wide. The word"EXIT" shall Exceptions: <br /> have letters having a width not less than 2 inches (51 mm) 1. Where handrail fittings or bendings are used to pro- <br /> wide, except the letter "I," and the minimum spacing vide continuous transition between flights, the fit- <br /> between letters shall be not less than 3/8 inch (9.5 mm). tings or bendings shall be pernutted to exceed the <br /> Signs larger than the minimum established in this section maximum height. <br /> shall have letter widths, strokes and spacing in proportion <br /> to their height. 2. In Group R-3 occupancies; within dwelling units in <br /> Group R-2 occupancies; and in Group U occupan- <br /> The word "EXIT" shall be in high contrast with the cies that are associated with a Group R-3 occupancy <br /> background and shall be clearly discernible when the or associated with individual dwelling units in <br /> means of exit sign illumination is or is not energized. If a Group R-2 occupancies; where handrail fittings or <br /> chevron directional indicator is provided as part of the exit bendings are used to provide continuous transition <br /> sign,the construction shall be such that the direction of the between flights, transition at winder treads, transi- <br /> chevron directional indicator cannot be readily changed. tion from handrail to guard, or where used at the <br /> 1013.6.2 Exit sign illumination. The face of an exit sign start of a flight, the handrail height at the fittings or <br /> illuminated from an external source shall have an intensity bendings shall be pernutted to exceed the m�imum <br /> of not less than 5 footcandles(541ux). height. <br /> 1013.6.3 Power source.Exit signs shall be illuminated at 3. Handrails on top of a guard where pernutted along <br /> all rimes. To ensure continued illumination far a duration stepped aisles and ramped aisles in accordance with <br /> of not less than 90 minutes in case of primary power loss, Section 1029.15. <br /> the sign illumination means shall be connected to an emer- 1014.3 Handrail graspability. Required handrails shall <br /> gency power system provided from storage batteries, unit <br /> equipment or an on-site generator. The installation of the comply with Section 1014.3.1 or shall provide equivalent <br /> emergency power system shall be in accordance with graspability. <br /> Chapter 27. Exception: In Group R-3 occupancies; within dwelling <br /> Exceptions: units in Group R-2 occupancies; and in Group U occupan- <br /> cies that are accessory to a Group R-3 occupancy or acces- <br /> 1. Approved exit sign illumination means that pro- sory to individual dwelling units in Group R-2 <br /> vide continuous illumination independent of occupancies; handrails shall be Type I in accordance with <br /> external power sources for a duration of not less Section 10143.1, Type II in accordance with Section <br /> than 90 minutes, in case of primary power loss, 10143.2 or shall provide equivalent graspability. <br /> are not required to be connected to an emergency <br /> electrical system. 1014.3.1 Type L Handrails with a circular cross section <br /> shall have an outside diameter of not less than 1'/4 inches <br /> ' 2. Group I-2 Condition 2 exit sign illumination shall (32 mm)and not greater than 2 inches(51 mm).Where the <br /> not be provided by unit equipment battery only. handrail is not circular,it shall have a perimeter dimension <br /> of not less than 4 inches(102 mm)and not greater than 6'/4 <br /> SECTION 1014 inches (160 mm) with a maximum cross-sectional dimen- <br /> HANDRAILS sion of 2/4 inches (57 mm) and minimum cross-sectional <br /> dimension of 1 inch(25 mm).Edges shall have a mimmum <br /> 1014.1 Where required. Handrails serving stairways, radius of 0.01 inch(0.25 mm). <br /> ramps, stepped aisles and ramped aisles shall be adequate in 1014.3.2 Type II.Handrails with a perimeter greater than <br /> strength and attachment in accordance with Section 1607.8. 6'/4 inches (160 mm) shall provide a graspable finger <br /> Handrails required far stairways by Section 1011.11 shall recess area on both sides of the profile. The finger recess <br /> comply with Sections 1014.2 through 1014.9. Handrails shall begin within a distance of 3/4 inch(19 mm)measured <br /> required for ramps by Section 1012.8 shall comply with Sec- vertically from the tallest portion of the profile and <br /> tions 1014.2 through 1014.8.Handrails far stepped aisles and achieve a depth of not less than 5/16 inch(8 mm) within'/g <br /> ramped aisles required by Section 1029.15 shall comply with inch(22 mm)below the widest portion of the profile.This <br /> Sections 1014.2 through 1014.8. required depth shall continue for not less than 3/8 inch (10 <br /> 1014.2 Height.Handrail height, measured above stair tread mm) to a level that is not less than 13/4 inches (45 mm) <br /> nosings,or finish surface of ramp slope,shall be uniform,not below the tallest portion of the profile. The width of the <br /> less than 34 inches (864 mm) and not more than 38 inches handrail above the recess shall be not less than 1'/,inches <br /> (965 mm). Handrail height of alternating tread devices and (32 mm) to not greater than 23/4 inches (70 mm). Edges <br /> ships ladders, measured above tread nosings, shall be uni- shall have a minimum radius of 0.01 inch(0.25 mm). <br /> 2015 INTERNATIONAL BUILDING CODE° 273 <br />