My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2531 WETMORE AVE 2017 THE SHIELDS LAW FIRM Plans 2022-12-01
>
Address Records
>
WETMORE AVE
>
2531
>
THE SHIELDS LAW FIRM
>
Plans
>
2531 WETMORE AVE 2017 THE SHIELDS LAW FIRM Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 1:24:37 PM
Creation date
6/6/2018 10:35:42 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2531
Tenant Name
THE SHIELDS LAW FIRM
Permit
B1702-008
Year
2017
Notes
BUILDOUT INTERIOR FOR OFFICES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M C �N I V�L N � VENTIL{�T�ON FINIS� SCHED�L� UNSPRINKLEREDBUILDING <br /> CHAPTER 4 IMC, CHAPTER 403.8 WAC CHAPTER 51-51 AND 5 IMC. <br /> ROOM WALLS CLASS FLOOR CLASS CEILING CLASS <br /> 2015 WA STATE ENERGY CODE <br /> INTERNATIONAL MECHANICAL CODE 2015 CONTROL AND OPERATION LOBBY PAINTED GYPSUM BOARD C PORCELAIN TILE 0 PAINTED GYPSUM BOARD C <br /> AND AS AMENDED BY LOCAL ORDINANCES <br /> 2015 INTERNATIONAL FUEL GAS CODE LOCATION OF CONTROLS SHALL BE READILY ACCESSIBLE. coNFERENCE C CARPET �� � <br /> 2015 UNIFORM PLUMBING CODE OPERATING INSTRUCTIONS FOR WHOLE HOUSE VENTILATION <br /> 2015 LIQUIFIED PETROLEUM GAS CODE SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE <br /> WSTALLER OF THE SYSTEM. coRR►�oR a PORCELAW TILE B <br /> ��A�I N G. 401.4 INTAKE OPENINGS STAIRWAY #1 A CARPET �� PAINTED GYPSUM BOARD A <br /> �, 1. INTAKE OPENINGS TO BE A MINIMUM OF 10' FROM LOT LINES OFFICE 1 c II 0 PAINTED GYPSUM BOARD � <br /> OR BUILDWGS ON THE SAME LOT. <br /> 2. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS OFFICE 2 c �� c <br /> 12. RETURN AIR PER SECTION 403 I.M.0 SHALL BE LOCATED NOT LESS THAN 10 FT HORIZONTAL <br /> 13. SUPPLY AIR PER SEGTION 403 I.M.C. FROM ANY HAZARDOUS OR NOXIOUS SOURCE. OFFICE 3 C 'f C <br /> MECHANICAL SYSTEMS PER CHAPTER 14, WSEC 2015 " C <br /> 3. INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 3 FT COPY RM c <br /> 14. AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR EACH SEPARATE BELOW CONTAMINAT SOURCES WHERE SUCH SOURCES ARE <br /> HEATING AND COOLING SYSTEM. LOCATED WITHIN 10 FT OF THE OPENING.. KITCHEN C PORCELAIN TILE C <br /> TOILET 1 C PORCELAIN TILE PAWTED GYPSUM BOARD C <br /> CONFERENCE ROOM: <br /> MIN.VENTILATION RATES: 5 CFM PER PERSON <br /> AREA OUTDOoR AIRFLOW RATE IN BREATHING ZONE Ra: 0.06 cfmisqft DOOR SCHEDULE <br /> ROOM NUMBER SIZE OPERATION U-VAL LOCK FIRE RATING GLASS CLOSER AREA <br /> TYPE <br /> LOBBY ENTRY � �� � SOLID WOOD LEVER HANDLE LATCH 0.3 KEY LOCK NONE SAFETY GLASS YES 24.5 <br /> � 3-6 X 7-0 CORE DOOR BOTH SIDES REQUIRED <br /> STAIR ENTRY 2 3'-0"X 7'-0 0.3 KEY LOCK YES 21 <br /> CONFERENCE ROOM 3 3�-6° X 7�-O NA NO <br /> OFFICE 1 4 3'-0"X 7'-0 <br /> u� <br /> OFFICE 2 5 � <br /> 0 <br /> Z <br /> OFFICE 3 g � <br /> � <br /> � <br /> OFFICE 4 7 KEY LOCK � <br /> O <br /> KITCHEN $ POCKET DOOR NO � <br /> > <br /> W <br /> TOILET 1 9 NO � <br /> � � <br /> CORRIDOR 10 NO YES �' � <br /> c� � <br /> cu <br /> TOILET 2 11 <br /> NO NO r" <br /> REAR ENTRY �2 0.3 KEY LOCK YES YES 2� �- o <br /> SAFETY GLASS z <br /> � <br /> � <br /> a o <br /> 0 o U o <br /> o �u� c� o <br /> o '> c o <br /> a� <br /> a (Y � �, o <br /> � L G <br /> O 0 m <br /> � U Z <br /> DUCTWORK WINDOW SCHEDULE � <br /> � � <br /> O U � �y i0 <br /> .�. > p 3 � O <br /> o z � v a <br /> 20. DUCT SYSTEMS SHALL BE OF METAL AS SET FORTH IN <br /> TABLES NO. 603.4 IMC ROOM NUMBER SIZE FRAME: U-VAL SHGC SAFETY GLASS AREA <br /> � <br /> 21. JOINTS AND SEAMS SHALL BE SUBSTANTIALLY AIRTIGHT, 4� <br /> SEC. 603.9 IMC <br /> 22. INSTALLATION OF DUCTS SHALL COMPLY WITH SEC. 603 IMC LOBBY � 4'-8"X 5 VINYL 0.30 0.64 YES 23.3 � <br /> 0 <br /> 23. DUCT INSULATION SHALL BE INSTALLED IN ACCORDANCE WITH ~ <br /> TAB. 5-11 OF 2015 WA STATE ENERGY CODE. � � m -� a � � <br /> CONF. RM Z 4 X 5 YES 20 ; a n m °� <br /> � � � � <br /> � °� � 3 a <br /> C Y U <br /> " � $ U � C N <br /> '�nU i 'u �'U 3 O <br /> CONF. RM 3 4 X 5 YES 2� o o � r� v� a <br /> 25. INSTALLATION OF DUCTS IN EXTERIOR WALLS, FLOORS OR CEILWGS <br /> SHALL NOT DISPLACE REQUIRED ENVELOPE INSULATION. <br /> 26. DUCT TESTING. DUCTS SHALL BE LEAK TESTED IN ACCORDANCE WITH LOBBY 4 4'-8"X 1'-4" N� 62 <br /> WSU RS-33, UNSING THE MAX DUCT LEAKAGE RATES SPECIFIED. <br /> � <br /> EXCEPTION; THE TOTAL LEAKAGE TEST OR LEAKAGE TO THE OUTDOORS IS CONF. RM 5 4 X 1'-4" NO 5.32 <br /> NOT REQUIRED FOR DUCTS AND AIR HANDLERS LOCATED ENTIRELY WITHIN � � <br /> THE BUILDING THERMAL ENVELOPE. FOR FORCED AIR DUCTS,A MAX OF 10 FT � � �y <br /> OF RETURN DUCTS AND 5 FT OF SUPPLY DUCTS MAY BE LOCATED OUTSIDE CONF. RM 6 4 X 1'-4" NO 5.32 � IY_ <br /> Cs� <br /> THE CONDITIONED SPACE. DUCTS IN CRAWLSPACE NO NOT QUALIFY FOR �,y� � � <br /> THIS EXCEPTION. SEE R403.3.3 WSEC FOR M�RE DETAILS. 80 TOTAL (,� �" � � <br /> � � <br /> Q � � �``v' <br /> W � � r'�v <br /> �! � � ,�i' <br /> m � O <br /> � � <br /> � <br /> � <br /> � <br /> _ � <br /> �_ � <br /> � N <br /> �N C <br /> O U <br /> 2015 <br /> WA STATE ENERGY CODE COMPLIANCE <br /> TARGETVS.PROPOSED TABLE C402.1 .3 � � <br /> PROTECTION AGAINST COROSSION TARGET(TO BE METZ WOOD FRAMED WALL : R-21 &INTERMEDIATE FRAMWG � � � <br /> AREA U-VAL AREA UA R-10 INSUL. HEADERS � <br /> ROOF INSUL: R-49 � � <br /> non-metal framing DOOR 0•6 66.5 39.9 �( � {~ <br /> METALLIC PIPE OR TUBING EXPOSED TO CORROSIVE ACTION, non-metal framing GLASS FIXED o.so gp za.o � � � <br /> SUCH AS SOIL CONDITION OR MOISTURE, SHALL BE PROTECTED W ' � � <br /> TOTAL 125.5 63.9 TABLE C402.4 ���� ������ `��� o � � <br /> AN APPROVED MANNER AND CATHODICALLY PROTECTED IN � � � <br /> ACCORDANCE WITH NACE RP-01-69 ��'� W �.. � <br /> PROPOSED TOTAL UA GLAZING U FACTOR <br /> � � <br /> ZINC OR GALV. SHALL NOT BE ADEQUATE PROTECTION FOR GAS NON-METAL FRAMING: 0.30 � � <br /> PIPING UDERGROUND AREA U-VAL RE ua <br /> non-metal framing DOOR 0•3 66.5 19�95 SHGC ���� �� ����� � � °' <br /> FERROUS METAL EXPOSED IN EXTERIOR LOCATIONS SHALL BE non-meta�framing GLASS FIXED o.s gp z4 ��`�� Q� �����►���Qt°� � m <br /> PROTECTED FROM CORROSION IN A MANNER SATISFACTORY TO TOTAL 43.95 �NEST FACING: PF < 0.2 : 0.4 � o Q <br /> THE CODE OFFICIAL. .2 <= PF < .5 o.4s - <br /> PF >_ .5 0.64� �-.���� , sca�e <br /> �# Sheet Scale <br /> WHERE DISSIIVIILAR METALS ARE JOINED UNDERGROUND, AN 43.95<63.9 oK <br /> WSULATION COUPLING OR FITTING SHALL BE USED. PF PRo�ECT�oN FACTOR: PF=fvB DrawingNo. <br /> PIPING SHALL NOT BE LAID IN CONTACT WITH CINDERS. NON-oPAQUE �ooRs To ExT. sHA��coMP�Y PF =6 FT/7.66'=o.7s �� <br /> WITH C402.3(VERT FENES.) <br /> af <br />
The URL can be used to link to this page
Your browser does not support the video tag.